ABB 1SFL607063R1122 Block Contactor - UL 60947-4-1 / 1000V
Part Number: 1SFL607063R1122
Quick Summary
ABB block contactor 1SFL607063R1122 provides robust motor control for industrial automation and machine building. In demanding panels, voltage fluctuations and energy waste can undermine reliability; AF technology broadens the control voltage range and reduces panel energy draw. It carries CE and UKCA declarations, UL/CSA approvals and IEC/EN standards, ensuring safe, compliant operation across global installations. Coupled with a compact footprint and easy expansion through add-on auxiliary blocks, it delivers dependable performance with lower lifecycle costs. This makes it a practical choice for motor protection and control in conveyors, pumps, presses, and packaging lines.
Product Information
Extended Description
1SFL607063R1122 ABB: The AF370B-30-22-11 is a 3 pole - 1000 V IEC or 600 V UL contactor with pre-mounted auxiliary contacts and standard ferrules, controlling motors up to 200 kW / 400 V AC (AC-3) or 300 hp / 480 V UL and switching power circuits up to 600 A (AC-1) or 520 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (24-60 V 50/60 Hz and 20-60 V DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100214C0202 - Main catalog Motor protection and control Manual motor starters, contactors and overload relays (PDF) - Edition 2024
Data Sheet, Technical Information (Part 2)
Contactors and Overload relays guide
Instructions and Manuals
Operating instruction, Contactor, AF(S)190 ... AF(S)370
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Dimension Diagram
Dimension Drawing, Contactor, AF265, AF305,AF370
Product Net Width
140 mm
Product Net Depth / Length
180 mm
Product Net Height
225 mm
Product Net Weight
3.9 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
2
Number of Auxiliary Contacts NC
2
Number of Poles
3P
Standards
IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1, IEC 60077-1 (applicable parts), IEC 60077-2 (applicable parts), EN 50155 (applicable parts), TR CU 001/2011, IEC 61373, For compliance confirmation on applicable parts based on your application and combination, please consult your ABB sales representatives.
Rated Operational Voltage
Main Circuit 1000 V
Rated Operational Current AC-1 (Ie)
(1000 V) 40 °C 400 A | (1000 V) 60 °C 350 A | (1000 V) 70 °C 290 A | (690 V) 40 °C 600 A | (690 V) 60 °C 500 A | (690 V) 70 °C 400 A
Rated Operational Current AC-3 (Ie)
(415 V) 55 °C 370 A | (440 V) 55 °C 370 A | (500 V) 55 °C 350 A | (690 V) 55 °C 315 A | (1000 V) 55 °C 100 A | (380 / 400 V) 55 °C 370 A | (220 / 230 / 240 V) 55 °C 370 A
Rated Operational Current DC-1 (Ie)
(100 V) 1 Pole, 40 °C 520 A | (100 V) 1 Pole, 60 °C 500 A | (100 V) 1 Pole, 70 °C 400 A | (110 V) 1-Pole, 40 °C 520 A | (110 V) 1-Pole, 60 °C 500 A | (110 V) 1-Pole, 70 °C 400 A | (110 V) 2 Poles in Series, 40 °C 520 A | (110 V) 2 Poles in Series, 60 °C 500 A | (110 V) 2 Poles in Series, 70 °C 400 A | (110 V) 3 Poles in Series, 40 °C 520 A | (110 V) 3 Poles in Series, 60 °C 500 A | (110 V) 3 Poles in Series, 70 °C 400 A | (175 V) 2 Poles in Series, 40 °C 520 A | (175 V) 2 Poles in Series, 60 °C 500 A | (175 V) 2 Poles in Series, 70 °C 400 A | (200 V) 2 Poles in Series, 40 °C 520 A | (200 V) 2 Poles in Series, 60 °C 500 A | (200 V) 2 Poles in Series, 70 °C 400 A | (220 V) 2 Poles in Series, 40 °C 520 A | (220 V) 2 Poles in Series, 60 °C 500 A | (220 V) 2 Poles in Series, 70 °C 400 A | (220 V) 3 Poles in Series, 40 °C 520 A | (220 V) 3 Poles in Series, 60 °C 500 A | (220 V) 3 Poles in Series, 70 °C 400 A | (260 V) 3 Poles in Series, 40 °C 520 A | (260 V) 3 Poles in Series, 60 °C 500 A | (260 V) 3 Poles in Series, 70 °C 400 A | (300 V) 3 Poles in Series, 40 °C 520 A | (300 V) 3 Poles in Series, 60 °C 500 A | (300 V) 3 Poles in Series, 70 °C 400 A | (340 V) 3 Poles in Series, 40 °C 520 A | (340 V) 3 Poles in Series, 60 °C 500 A | (340 V) 3 Poles in Series, 70 °C 400 A | (72 V) 1-Pole, 40 °C 520 A | (72 V) 1-Pole, 60 °C 500 A | (72 V) 1-Pole, 70 °C 400 A | (72 V) 2 Poles in Series, 40 °C 520 A | (72 V) 2 Poles in Series, 60 °C 500 A | (72 V) 2 Poles in Series, 70 °C 400 A | (72 V) 3 Poles in Series, 40 °C 520 A | (72 V) 3 Poles in Series, 60 °C 500 A | (72 V) 3 Poles in Series, 70 °C 400 A | (90 V) 1 Pole, 40 °C 520 A | (90 V) 1 Pole, 60 °C 500 A | (90 V) 1 Pole, 70 °C 400 A
Rated Operational Current DC-3 (Ie)
(110 V) 2 Poles in Series, 40 °C 450 A | (110 V) 2 Poles in Series, 60 °C 450 A | (110 V) 2 Poles in Series, 70 °C 400 A | (110 V) 3 Poles in Series, 40 °C 450 A | (110 V) 3 Poles in Series, 60 °C 450 A | (110 V) 3 Poles in Series, 70 °C 400 A | (220 V) 3 Poles in Series, 40 °C 450 A | (220 V) 3 Poles in Series, 60 °C 450 A | (220 V) 3 Poles in Series, 70 °C 400 A | (72 V) 2 Poles in Series, 40 °C 450 A | (72 V) 2 Poles in Series, 60 °C 450 A | (72 V) 2 Poles in Series, 70 °C 400 A | (72 V) 3 Poles in Series, 40 °C 450 A | (72 V) 3 Poles in Series, 60 °C 450 A | (72 V) 3 Poles in Series, 70 °C 400 A
Rated Operational Current DC-5 (Ie)
(110 V) 2 Poles in Series, 40 °C 450 A | (110 V) 2 Poles in Series, 60 °C 450 A | (110 V) 2 Poles in Series, 70 °C 400 A | (110 V) 3 Poles in Series, 40 °C 450 A | (110 V) 3 Poles in Series, 60 °C 450 A | (110 V) 3 Poles in Series, 70 °C 400 A | (220 V) 3 Poles in Series, 40 °C 450 A | (220 V) 3 Poles in Series, 60 °C 450 A | (220 V) 3 Poles in Series, 70 °C 400 A | (72 V) 2 Poles in Series, 40 °C 450 A | (72 V) 2 Poles in Series, 60 °C 450 A | (72 V) 2 Poles in Series, 70 °C 400 A | (72 V) 3 Poles in Series, 40 °C 450 A | (72 V) 3 Poles in Series, 60 °C 450 A | (72 V) 3 Poles in Series, 70 °C 400 A
Rated Operational Power AC-3 (Pe)
(415 V) 200 kW | (440 V) 200 kW | (500 V) 250 kW | (690 V) 315 kW | (1000 V) 200 kW | (380 / 400 V) 200 kW | (220 / 230 / 240 V) 110 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 2960 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 600 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 1208 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 3700 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 1709 A
Rated Insulation Voltage (Ui)
acc. to UL/CSA 1000 V
Mechanical Durability
5 million
Maximum Mechanical Switching Frequency
300 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz / 60 Hz 24 ... 60 V | DC Operation 20 ... 60 V
Coil Consumption
Holding at Max. Rated Control Circuit Voltage 50 Hz 8.5 V·A | Holding at Max. Rated Control Circuit Voltage 60 Hz 8.5 V·A | Pull-in at Max. Rated Control Circuit Voltage 50 Hz 475 V·A | Pull-in at Max. Rated Control Circuit Voltage 60 Hz 475 V·A | Pull-in at Max. Rated Control Circuit Voltage DC 400 W
Power Loss
27 W | at Rated Operating Conditions per Pole 27 W
Terminal Type
Main Circuit: Bars
Product Name
Block Contactor
General Use Rating UL/CSA
(1000 V AC) 520 A
Horsepower Rating UL/CSA
(200 ... 208 V AC) Three Phase 125 hp | (220 ... 240 V AC) Three Phase 150 hp | (440 ... 480 V AC) Three Phase 300 hp | (550 ... 600 V AC) Three Phase 350 hp
Full Load Amps Motor Use
(200 ... 208 V AC) Three Phase 359 A | (220 ... 240 V AC) Three Phase 360 A | (440 ... 480 V AC) Three Phase 361 A | (550 ... 600 V AC) Three Phase 336 A
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
Non-hazardous waste is sent to a landfill, where there is no alternative option available within 100km of a facility
End Of Life Disassembling Instructions
End-of-life instruction - AF(S)265(B)-**(RT) to AF(S)370(B)-**(RT)
Environmental Product Declaration - EPD
Environmental Product Declaration, Contactors, AF(S)265-AF(S)370 (SE)
Improved Energy Efficiency for Customers
Product Efficiency - Product considered more energy-efficient compared to similar product on market or older products from the same line
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 76.3 %
Sustainable Material Content in Product (wt. %)
Recycled Metal - 33 %
A2L Certificate – UL
UL Certificate of Compliance A2L, Contactor, AF190 - AF370
CB Certificate
SE-89316
CQC Certificate
CQC Certificate, AC Contactor, AF265-*-*-*,AF305-*-*-*,AF370-*-*-*,AF265B-*-*-*,AF305B-*-*-*,AF370B-*-*-*, Made in Sweden
Declaration of Conformity - CCC
CCC Declaration of Conformity, AC Contactor, AF265-*-*-*,AF305-*-*-*,AF370-*-*-*,AF265B-*-*-*,AF305B-*-*-*,AF370B-*-*-*, Made in Sweden
Declaration of Conformity - CE
CE Declaration of Conformity - Contactor - AF116B...RT to AF370B...RT
Declaration of Conformity - UKCA
UK Declaration of Conformity - Contactors >100A - Rail application
EAC Certificate
9AKK107046A8618
UL Certificate
cULus Certificate, Contactor, AF265, AF305, AF370, AX260, AX300, AX370, AFS265, AFS305, AFS370
Package Level 1 Units
box 1 piece
Package Level 1 Width
263 mm
Package Level 1 Depth / Length
203 mm
Package Level 1 Height
289 mm
Package Level 1 Gross Weight
4.6 kg
Package Level 1 EAN
7320500510988
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
E-Number (Sweden)
3210456
Feature AF technology enables a wide control voltage range, reducing energy consumption in networks with voltage variation. Business Impact Lower panel energy draw and improved reliability in unstable networks. Application Suitable for motor protection and control in automation panels where 24-60 V control is common. Feature Three-pole main contacts with 2 NO and 2 NC auxiliary contacts, pre-mounted and extendable with add-on blocks. Business Impact Flexible configuration supports scalable control architectures and simplified wiring. Application Ideal for conveyors, pumps and machine tools, enabling compact, modular installations. Feature Built-in surge protection for enhanced protection of connected loads. Business Impact Reduces panel transients and improves lifecycle reliability. Application Fits a compact footprint 140 × 180 × 225 mm and weighs 3.9 kg, with main circuit bars for straightforward mounting. Feature AF footprint and accessories compatibility ensure easy expansion and serviceability. Business Impact Minimizes retrofit time and saves on spare parts. Application Works with AF265–AF370 family accessories to tailor control and signaling as needed.
Get a Quick Quote for a ABB 1SFL607063R1122
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SFL607063R1122?
Enquire Now
FAQs
Begin by confirming the coil voltage matches your control circuit (24–60 VAC/VDC). Mount the unit using the main circuit bars and secure it in a clean panel space. Wire the main three poles to the load side and attach two NO auxiliary contacts as required. If expansion is needed, add auxiliary contact blocks from the AF family. Ensure adherence to IEC/EN 60947-4-1 and leave appropriate clearance for heat and ventilation.
For AC-3 operation, the contactor provides up to 370 A at 415–690 V depending on the voltage and temperature class. At 1000 V it offers approximately 100 A in some configurations, while at lower voltages such as 380–400 V the rating can reach about 370 A. Always verify intended voltage, ambient temperature, and enclosure conditions to select the correct rating within the spec sheet.
Yes, the device includes DC-1, DC-3 and DC-5 ratings across multiple voltages (for example 110 V and 72 V DC configurations) with several poles in series. However, you must ensure you operate within the specified Ie values for each DC configuration and consider derating for temperature and duty cycle. Use this model where DC control is required in combinations with its AC main contacts.
The 1SFL607063R1122 supports CE and UKCA declarations, UL/CSA general-use ratings, and IEC/EN 60947-1 and 60947-4-1, along with RoHS and REACH compliance. It also carries EAC and additional certificates such as UL certificates for compatibility with global safety and environmental regulations. When designing for global markets, reference these certifications to meet regulatory requirements.
The contactor has a compact footprint of 140 mm in width, 180 mm in depth, and 225 mm in height. It weighs about 3.9 kg (net), with a packaged level-1 weight of approximately 4.6 kg. This makes it suitable for integration into compact control panels while maintaining clearance for wiring and cooling.