ABB 1SFL607074R8011 Contactor - UL/cUL Listed
Part Number: 1SFL607074R8011
Quick Summary
ABB 1SFL607074R8011 Contactor provides reliable motor control for heavy‑duty manufacturing and process automation. This solution addresses downtime and nuisance tripping by delivering robust surge immunity and precise coil control under demanding loads. The block contactor carries UL/cUL recognition, CE declaration of conformity, and RoHS/REACH compliance, enabling confident global deployment. Its 690 V insulation, high I th and AC-3 current ratings support long life in continuous operation, while the 3P configuration and built‑in auxiliary contacts streamline control wiring. Designed to integrate with ABB's AX370 family, it supports scalable architectures, simplifies maintenance, and reduces total cost of ownership across motor-starting applications.
Product Information
Extended Description
1SFL607074R8011 ABB: AX370-30-11-80 Contactor
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100214C0202 - Main catalog Motor protection and control Manual motor starters, contactors and overload relays (PDF) - Edition 2024
Instructions and Manuals
1SFC101062M0201_E
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
140 mm
Product Net Depth / Length
180 mm
Product Net Height
225 mm
Product Net Weight
4.7 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
1
Number of Auxiliary Contacts NC
1
Number of Poles
3P
Rated Operational Voltage
Main Circuit 1000 V
Rated Frequency (f)
Main Circuit 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 250 A
Rated Operational Current AC-1 (Ie)
(690 V) 40 °C 600 A | (690 V) 55 °C 500 A | (690 V) 70 °C 400 A
Rated Operational Current AC-3 (Ie)
(415 V) 55 °C 370 A | (440 V) 55 °C 370 A | (500 V) 55 °C 315 A | (690 V) 55 °C 315 A | (380 / 400 V) 55 °C 370 A | (220 / 230 / 240 V) 55 °C 370 A
Rated Operational Power AC-3 (Pe)
(415 V) 200 kW | (440 V) 200 kW | (500 V) 250 kW | (690 V) 315 kW | (380 / 400 V) 200 kW | (220 / 230 / 240 V) 110 kW
Rated Breaking Capacity AC-3
8 x Ie AC-3
Rated Making Capacity AC-3
10 x Ie AC-3
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 2960 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 600 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 1208 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 3700 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 1709 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
Rated Impulse Withstand Voltage (Uimp)
8 kV
Maximum Electrical Switching Frequency
300 cycles per hour
Mechanical Durability
5 million
Maximum Mechanical Switching Frequency
300 cycles per hour
Coil Operating Limits
(acc. to IEC 60947-4-1) Uc (at θ ≤ 70 °C)
Rated Control Circuit Voltage (Uc)
50 Hz 220 ... 230 V | 60 Hz 230 ... 240 V
Power Loss
at Rated Operating Conditions per Pole 27 W
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP40
Terminal Type
Main Circuit: Bars
Product Name
Block Contactor
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 55 °C | Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C | Close to Contactor for Storage -40 ... 70 °C
Maximum Operating Altitude Permissible
Without Derating 3000 m
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
CQC Certificate
CQC Certificate, Contactor, AX260, AX300, AX370, Made in China
Declaration of Conformity - CCC
CCC Declaration of Conformity, Contactor, AX260, AX300, AX370, Made in China
Declaration of Conformity - CE
CE Declaration of conformity - Contactor - AX95...AX370
UL Certificate
cULus Certificate, Contactor, AF265, AF305, AF370, AX260, AX300, AX370, AFS265, AFS305, AFS370
Package Level 1 Units
box 1 piece
Package Level 1 Width
175 mm
Package Level 1 Depth / Length
270 mm
Package Level 1 Height
223 mm
Package Level 1 Gross Weight
5.4 kg
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
Feature: 3-pole main contacts NO 3 and auxiliary NO 1 / NC 1; Business Impact: reduces wiring complexity and enables reliable interlocking; Application: suitable for conveyors, pumps and fans in mid-size automation. Feature: Rated insulation voltage Ui of 690 V and main circuit rating up to 1000 V; Business Impact: accommodates higher voltage motor circuits and wider installation flexibility; Application: plant-wide motor control in 380–690 V networks. Feature: AC-3 rated current up to 315 A at 690 V and AC-3 power up to 315 kW; Business Impact: supports larger motors with fewer devices and lower total cost of ownership; Application: heavy-duty motors in packaging lines, material handling, and processing equipment. Feature: Short-time withstand current up to 3700 A for 1 s and 2960–3700 A ranges for brief surges; Business Impact: improved fault tolerance and protective coordination; Application: critical power circuits with rapid fault clearance. Feature: Compact footprint with 140 mm width, 180 mm depth and 225 mm height; Business Impact: easier panel integration and enclosure optimization; Application: control cabinets and remote motor starters. Feature: Mechanical durability rated at 5 million cycles; Business Impact: long service life reduces maintenance and replacement costs; Application: high-cycle starting in continuous production environments. Feature: RoHS/REACH/WEEE compliance and multiple certifications; Business Impact: regulatory compliance for global deployments; Application: production facilities in Europe, North America, and Asia. Feature: CAD data availability and 2D/3D files support; Business Impact: speeds engineering and reduces installation lead times; Application: OEMs and system integrators designing tight control panels.
Get a Quick Quote for a ABB 1SFL607074R8011
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SFL607074R8011?
Enquire Now
FAQs
Install with proper panel clearance, mount using standard 3‑pole mounting pattern, wire the main circuit in bars and connect the auxiliary contacts for interlocking. Verify coil voltage matches 50 Hz 220–230 V or 60 Hz 230–240 V as specified, and ensure appropriate propulsion of the protective devices in the circuit.
For AC-3 ( Ie ) at 690 V, the contactor is rated up to 315 A. This supports motors up to approximately 315 kW in the AC-3 operating mode at 690 V.
The unit carries UL/cUL certification, CE declaration of conformity, CQC and CCC attestations, and RoHS/REACH compliance, ensuring global regulatory readiness and safe use in diverse markets.
It operates from −25°C to 55°C with thermal overload relay fitted, up to 70°C without relay, at altitudes up to 3000 m, and includes IP40 auxiliary terminal protection. It is designed for 50/60 Hz mains and can handle continuous heavy-duty cycles.
Yes, CAD dimensional drawings are available in 2D and 3D formats to streamline integration into electrical schematics and enclosure layouts, reducing engineering lead times.