ABB 1SFL607102R1400 Contactor is a four-pole motor switch for 200 kW AC drives. In fluctuating networks, wide control voltage tolerance minimizes nuisance tripping and energy waste. This AF family device carries CE, UL/CSA and UKCA certifications, with RoHS/REACH compliance for global use. Designed for easy integration with AF accessory blocks, it helps OEMs and panel builders reduce wiring complexity and total cost of ownership. The built-in surge protection and compact block design also support faster commissioning and reliable operation in demanding environments.
Product Information
Extended Description
1SFL607102R1400 ABB: The AF370-40-00-14 is a 4 pole - 1000 V IEC or 600 V UL contactor with Main Circuit Bars, controlling motors up to 200 kW / 400 V AC (AC-3) / and switching power circuits up to 525 A (AC-1) or 420 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (250-500 V 50/60 Hz and DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100214C0202 - Main catalog Motor protection and control Manual motor starters, contactors and overload relays (PDF) - Edition 2024
Data Sheet, Technical Information (Part 2)
Contactors and Overload relays guide
Instructions and Manuals
Operating instruction, Contactor, AF(S)190 ... AF(S)370
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Dimension Diagram
Dimension Drawing. Contactor,AF265,AF305,AF370
Product Net Width
184 mm
Product Net Depth / Length
180 mm
Product Net Height
225 mm
Product Net Weight
5.7 kg
Number of Main Contacts NO
4
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
0
Number of Auxiliary Contacts NC
0
Number of Poles
4P
Rated Operational Voltage
Main Circuit 1000 V
Rated Frequency (f)
Main Circuit 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 525 A
Rated Operational Current AC-1 (Ie)
(1000 V) 40 °C 400 A | (1000 V) 60 °C 350 A | (1000 V) 70 °C 290 A | (690 V) 40 °C 525 A | (690 V) 60 °C 425 A | (690 V) 70 °C 350 A
Rated Operational Current AC-3 (Ie)
(415 V) 55 °C 370 A | (440 V) 55 °C 370 A | (380 / 400 V) 55 °C 370 A | (220 / 230 / 240 V) 55 °C 370 A
Rated Operational Power AC-3 (Pe)
(415 V) 200 kW | (440 V) 200 kW | (380 / 400 V) 200 kW | (220 / 230 / 240 V) 110 kW
Rated Breaking Capacity AC-3
8 x Ie AC-3
Rated Making Capacity AC-3
10 x Ie AC-3
Short-Circuit Protective Devices
gG Type Fuses 630 A
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 2960 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 600 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 1208 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 3700 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 1709 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 5000 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V | acc. to UL/CSA 1000 V
Rated Impulse Withstand Voltage (Uimp)
Main Circuit 8 kV
Maximum Electrical Switching Frequency
(AC-1) 300 cycles per hour
Mechanical Durability
5 million
Maximum Mechanical Switching Frequency
300 cycles per hour
Coil Operating Limits
(acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C)
Rated Control Circuit Voltage (Uc)
50 Hz 250 ... 500 V | 60 Hz 250 ... 500 V | DC Operation 250 ... 500 V
Coil Consumption
Holding at Max. Rated Control Circuit Voltage 50 Hz 20.4 V·A | Holding at Max. Rated Control Circuit Voltage 60 Hz 20.4 V·A | Holding at Max. Rated Control Circuit Voltage DC 4.7 W | Pull-in at Max. Rated Control Circuit Voltage 50 Hz 550 V·A | Pull-in at Max. Rated Control Circuit Voltage 60 Hz 550 V·A | Pull-in at Max. Rated Control Circuit Voltage DC 650 W
Power Loss
72 W | at Rated Operating Conditions per Pole 72 W
Operate Time
Between Coil De-energization and NO Contact Opening 45 ... 80 ms | Between Coil Energization and NO Contact Closing 30 ... 60 ms
Connecting Capacity Main Circuit
Flexible 2 x 70 ... 185 mm² | Rigid Al-Cable 1 x 185 ... 240 mm² | Rigid Cu-Cable 2 x 70 ... 185 mm²
Connecting Capacity Auxiliary Circuit
Flexible with Ferrule 2x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm² | Flexible 2x0.75 ... 2.5 mm² | Solid 2 x 1 ... 4 mm² | Stranded 1 x 1 .... 4 mm²
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Tightening Torque
Cable Lug 28 N·m | Main Circuit 22 ... 43 N·m
Terminal Type
Main Circuit: Bars
Product Name
Block Contactor
Maximum Operating Voltage UL/CSA
Main Circuit 1000 V
General Use Rating UL/CSA
(1000 V AC) 520 A
Horsepower Rating UL/CSA
(200 ... 208 V AC) Three Phase 50 Hp | (200 V AC) Three Phase 125 hp | (208 V AC) Three Phase 125 hp | (220 ... 240 V AC) Three Phase 60 Hp | (220 ... 240 V AC) Three Phase 150 hp | (440 ... 480 V AC) Three Phase 125 Hp | (440 ... 480 V AC) Three Phase 300 hp | (550 ... 600 V AC) Three Phase 150 Hp | (550 ... 600 V AC) Three Phase 350 hp
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °C | Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C | Close to Contactor for Storage -40 ... 70 °C
Maximum Operating Altitude Permissible
Without Derating 3000 m
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
Non-hazardous waste is sent to a landfill, where there is no alternative option available within 100km of a facility
End Of Life Disassembling Instructions
End-of-life instruction - AF(S)265(B)-**(RT) to AF(S)370(B)-**(RT)
Environmental Product Declaration - EPD
Environmental Product Declaration, Contactors, AF(S)265-AF(S)370 (SE)
Improved Energy Efficiency for Customers
Product Efficiency - Product considered more energy-efficient compared to similar product on market or older products from the same line
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 76.3 %
Sustainable Material Content in Product (wt. %)
Recycled Metal - 33 %
A2L Certificate – UL
UL Certificate of Compliance A2L, Contactor, AF190 - AF370
ABS Certificate
ABS Approval, Contactor, AF116 ... AF370 (Sweden)
BV Certificate
BV Certificate, Contactor, AF116-30 ... AF370-30...AF116-40...AF370-40
CB Certificate
SEMKO_SE-73326
CQC Certificate
CQC Certificate, AC Contactor, AF265-*-*-*,AF305-*-*-*,AF370-*-*-*,AF265B-*-*-*,AF305B-*-*-*,AF370B-*-*-*, Made in Sweden
Declaration of Conformity - CCC
CCC Declaration of Conformity, AC Contactor, AF265-*-*-*,AF305-*-*-*,AF370-*-*-*,AF265B-*-*-*,AF305B-*-*-*,AF370B-*-*-*, Made in Sweden
Declaration of Conformity - CE
CE Declaration of Conformity - Contactor - AF116...AF370
Declaration of Conformity - UKCA
UK Declaration of Conformity - Contactors >100A
EAC Certificate
9AKK107046A8618
LR Certificate
Lloyds register Certificate, Contactor, AF116-30 ... AF370-30, AF116-40...AF370-40
PRS Certificate
PRS Certificate - AF116...AF1650
RINA Certificate
RINA Certificate, AF95, AF110, AF145, AF185, AF210, AF260, AF300, AF400, AF460, AF580, AF750, AF1250, AF1350, AF1650, AF2050, AF2650, AF116, AF140, AF146, AF190, AF205, AF265, AF305, AF370
RMRS Certificate
9AKK107045A6978
UL Certificate
cULus Certificate, Contactor, AF265-40, AF305-40, AF370-40 (4-pole)
Package Level 1 Units
box 1 piece
Package Level 1 Width
212 mm
Package Level 1 Depth / Length
262 mm
Package Level 1 Height
212 mm
Package Level 1 Gross Weight
6.4 kg
Package Level 1 EAN
7320500504413
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4758 >> Iec Contactors
E-Number (Finland)
3707252
Feature: Wide control voltage range and AF technology allow stable coil operation across 250–500 V and DC control signals, reducing panel energy consumption and improving reliability in unstable networks. Business impact: Lower energy footprints in motor control cabinets and fewer trips translate to measurable savings across production lines. Application: Suitable for conveyors, pumps, and fans in food and beverage, plastics, and packaging facilities where supply quality varies. Feature: Built-in surge protection and a compact block design cut external protection needs and save panel space, while enhancing protection in harsh environments. Business impact: Reduced wiring, fewer external components, and easier compliance testing. Application: Panel builders deploying compact switchgear with tight footprints. Feature: Four-pole main circuit rated to 1000 V and high current ratings supports motors up to 200 kW at common European voltages. Business impact: Enables reliable start/stop of large drives with minimal wear on breakers and fuses. Application: OEMs designing industrial automation lines with high-demand motors. Feature: Compatibility with add-on auxiliary contact blocks and a wide accessory range offers scalable control schemes. Business impact: Simplified expansion for status signaling and remote control reduces rework during plant upgrades. Application: Systems requiring modular control logic and diagnostic capabilities. Feature: Durable mechanical design and clear standards compliance ensure long life in production environments. Business impact: Lower maintenance costs and predictable lifecycle planning. Application: Continuous process industries demanding high reliability.
Get a Quick Quote for a ABB 1SFL607102R1400
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SFL607102R1400?
Enquire Now
FAQs
Install the 4-pole block contactor using the main circuit bars rated for up to 1000 V. Use rigid Cu or Al cables within the 70–185 mm² range for the main circuit, and 0.75–2.5 mm² ferrule or solid wires for the auxiliary circuit. Tighten main circuit connections to 22–43 N·m and ensure coil terminals are IP20 protected per IEC standards.
The contactor provides AC-3 rated current up to 370 A at 415–440 V and 370 A at 380–400 V, enabling control of motors up to 200 kW at 415–440 V. For AC-1 service, it supports up to 525 A. This makes it suitable for high-inertia, motor-start applications in general-purpose drives.
Yes. The AF technology supports block-type expansion with add-on auxiliary contact blocks, and a broad accessory lineup. This enables scalable control schemes, remote signaling, and diagnostics without reworking existing switchgear. The design simplifies future upgrades and reduces retrofit costs in evolving automation environments.
The device carries CE, UKCA, and UL/CSA certifications, along with RoHS and REACH compliance. It also aligns with WEEE B2B considerations and related environmental declarations. Compliance supports global deployment and simplifies customer audits in regulated markets.
With a wide control voltage range, built-in surge protection, and a coil consumption profile that reduces idle power, it lowers energy use and component count. Mechanical durability reaches up to 5 million cycles, and compact dimensions save panel space. These features collectively improve uptime, reduce maintenance costs, and shorten payback in motor-driven lines.