ABB 1SFL617001R6811 Block Contactor - 1000 V
Part Number: 1SFL617001R6811
Quick Summary
Block Contactor ABB AF580-30-11 enables reliable motor control for large drives in industrial automation. Many facilities face voltage variation and energy waste, and this device’s 24–60 V DC coil range helps maintain consistent operation. It carries CE and UL/CSA certifications with UKCA labeling and IEC 60947-4-1 compatibility, reflecting robust global compliance. Designed for easy panel integration, it supports add-on auxiliary blocks and a wide range of accessories to grow with your system, boosting uptime and reducing lifecycle costs.
Product Information
Extended Description
1SFL617001R6811 ABB: The AF580-30-11-68 is a 3 pole - 1000 V IEC or 600 V UL contactor with pre-mounted auxiliary contacts and Main Circuit Bars, controlling motors up to 315 kW / 400 V AC (AC-3) or 500 hp / 480 V UL and switching power circuits up to 800 A (AC-1) or 750 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (24-60 V DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100214C0202 - Main catalog Motor protection and control Manual motor starters, contactors and overload relays (PDF) - Edition 2024
Data Sheet, Technical Information (Part 2)
Contactors and Overload relays guide
Instructions and Manuals
1SFC380023-en
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Dimension Diagram
53540919-60
Product Net Width
210 mm
Product Net Depth / Length
242 mm
Product Net Height
283 mm
Product Net Weight
13.6 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
1
Number of Auxiliary Contacts NC
1
Number of Poles
3P
Rated Operational Voltage
Main Circuit 1000 V
Rated Frequency (f)
Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 800 A
Rated Operational Current AC-1 (Ie)
(1000 V) 40 °C 800 A | (1000 V) 55 °C 700 A | (1000 V) 70 °C 580 A | (690 V) 40 °C 800 A | (690 V) 55 °C 700 A | (690 V) 70 °C 580 A
Rated Operational Current AC-3 (Ie)
(415 V) 55 °C 580 A | (440 V) 55 °C 580 A | (500 V) 55 °C 580 A | (690 V) 55 °C 500 A | (1000 V) 55 °C 250 A | (380 / 400 V) 55 °C 580 A | (220 / 230 / 240 V) 55 °C 580 A
Rated Operational Current DC-1 (Ie)
(110 V) 1-Pole, 40 °C 800 A | (110 V) 2 Poles in Series, 40 °C 800 A | (220 V) 3 Poles in Series, 40 °C 800 A | (600 V) 3 Poles in Series, 40 °C 800 A | (850 V) 3 Poles in Series, 40 °C 800 A
Rated Operational Current DC-3 (Ie)
(110 V) 1-Pole, 40 °C 800 A | (110 V) 2 Poles in Series, 40 °C 800 A | (220 V) 3 Poles in Series, 40 °C 800 A | (600 V) 3 Poles in Series, 40 °C 800 A
Rated Operational Current DC-5 (Ie)
(110 V) 1-Pole, 40 °C 800 A | (110 V) 2 Poles in Series, 40 °C 800 A | (220 V) 3 Poles in Series, 40 °C 800 A | (600 V) 3 Poles in Series, 40 °C 800 A
Rated Operational Power AC-3 (Pe)
(415 V) 355 kW | (440 V) 355 kW | (500 V) 400 kW | (690 V) 500 kW | (1000 V) 355 kW | (380 / 400 V) 315 kW | (220 / 230 / 240 V) 160 kW
Rated Breaking Capacity AC-3
8 x Ie AC-3
Rated Making Capacity AC-3
10 x Ie AC-3
Short-Circuit Protective Devices
gG Type Fuses 1000 A
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 6400 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 1300 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 3500 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 7000 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 4500 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 6000 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 5000 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V | acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)
Main Circuit 8 kV
Maximum Electrical Switching Frequency
(AC-1) 300 cycles per hour | (AC-2 / AC-4) 60 cycles per hour | (AC-3) 300 cycles per hour
Mechanical Durability
3 million
Maximum Mechanical Switching Frequency
300 cycles per hour
Coil Operating Limits
(acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C)
Rated Control Circuit Voltage (Uc)
DC Operation 24 ... 60 V
Coil Consumption
Holding at Max. Rated Control Circuit Voltage 50 Hz 12 V·A | Holding at Max. Rated Control Circuit Voltage 60 Hz 12 V·A | Holding at Max. Rated Control Circuit Voltage DC 5.5 V·A | Pull-in at Max. Rated Control Circuit Voltage 50 Hz 780 V·A | Pull-in at Max. Rated Control Circuit Voltage 60 Hz 780 V·A | Pull-in at Max. Rated Control Circuit Voltage DC 785 V·A
Power Loss
at Rated Operating Conditions per Pole 32 W
Operate Time
Between Coil De-energization and NC Contact Closing 50 ... 70 ms | Between Coil De-energization and NO Contact Opening 53 ... 73 ms | Between Coil Energization and NC Contact Opening 45 ... 115 ms | Between Coil Energization and NO Contact Closing 50 ... 120 ms
Connecting Capacity Main Circuit
Bar 52 mm² | Rigid Al-Cable 3x185 mm² | Rigid Cu-Cable 300 mm²
Connecting Capacity Auxiliary Circuit
Flexible with Ferrule 2x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm² | Flexible 2x0.75 ... 2.5 mm² | Solid 2 x 1 ... 4 mm² | Stranded 2 x 1 .... 4 mm²
Connecting Capacity
Bar 52 mm² | Rigid Al-Cable 300 mm² | Rigid Cu-Cable 300 mm²
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Tightening Torque
Cable Lug 45 N·m | Main Circuit 45 N·m
Terminal Type
Main Circuit: Bars
Product Name
Block Contactor
Maximum Operating Voltage UL/CSA
Main Circuit 1000 V
General Use Rating UL/CSA
(1000 V AC) 750 A
Horsepower Rating UL/CSA
(200 V AC) Three Phase 200 hp | (208 V AC) Three Phase 200 hp | (220 ... 240 V AC) Three Phase 250 hp | (440 ... 480 V AC) Three Phase 500 hp | (550 ... 600 V AC) Three Phase 600 hp
Full Load Amps Motor Use
(440 ... 480 V AC) Three Phase 590 A | (550 ... 600 V AC) Three Phase 578 A
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °C | Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C | Close to Contactor for Storage -40 ... 70 °C
Maximum Operating Altitude Permissible
Without Derating 3000 m
Resistance to Shock acc. to IEC 60068-2-27
Shock Direction: A 5 g | Shock Direction: B1 5 g | Shock Direction: B2 5 g | Shock Direction: C1 5 g | Shock Direction: C2 5 g
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
End Of Life Disassembling Instructions
End-of-life instruction - AF(S)580(B)-**;AF(S)750(B)-**; AF750N7; AF1250(B)-**
Environmental Product Declaration - EPD
Environmental Product Declaration AF(S)580(F)(N), AF(S)750(F)(N), AF1250 (SE) Contactors
ABS Certificate
ABS Certificate, Contactor, AF400...AF2050 (Sweden)
BV Certificate
BV Certificate, Contactor, AF400 ... AF2850
CB Certificate
SE-82863
CCS Certificate
CCS Certificate, Contactor, AF116 to AF2850 (Sweden)
CQC Certificate
CQC Certificate, AC Contactor, AF580-30-*-*, AF750-30-*-* , AFS580-30-*-*, AFS750-30-*-*, Made in Sweden | CQC Certificate, Contactor, AF580, AF750, Made in China
Declaration of Conformity - CCC
CCC Declaration of Conformity, AC Contactor, AF580-30-*-*, AF750-30-*-* , AFS580-30-*-*, AFS750-30-*-*, Made in Sweden | CCC Declaration of Conformity, Contactor, AF580, AF750, Made in China
Declaration of Conformity - CE
CE Declaration of Conformity - Contactor - AF400...AF2850
Declaration of Conformity - UKCA
UK Declaration of Conformity - Contactors >100A
DNV Certificate
DNV_E-10966
DNV GL Certificate
DNV Certificate, Contactor, AF400...AF2850
EAC Certificate
9AKK107046A8618
GL Certificate
GL_42988-02HH
LOVAG Certificate
SE-0146175
LR Certificate
Lloyds register Certificate, Contactor, AF400...AF2850
PRS Certificate
PRS Certificate - AF116...AF1650
RINA Certificate
RINA Certificate, AF95, AF110, AF145, AF185, AF210, AF260, AF300, AF400, AF460, AF580, AF750, AF1250, AF1350, AF1650, AF2050, AF2650, AF116, AF140, AF146, AF190, AF205, AF265, AF305, AF370
RMRS Certificate
9AKK107045A6978
TÜV Certificate
MHM-EST-7.70017788e
UL Certificate
cULus Certificate, Contactor, AF580, AF750, AFS580, AFS750
UL Listing Card
UL_E36588
Package Level 1 Units
box 1 piece
Package Level 1 Width
280 mm
Package Level 1 Depth / Length
375 mm
Package Level 1 Height
310 mm
Package Level 1 Gross Weight
15 kg
Package Level 1 EAN
7320500220368
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4758 >> Iec Contactors
E-Number (Norway)
4115294
E-Number (Sweden)
3228352
Feature 1: Three main contacts and one auxiliary contact, rated for high-power motors up to 315 kW at 400 V AC (AC-3) and 580 A at 690 V. Business impact: enables compact yet capable motor starting and reliable power switching, reducing panel footprint and wiring complexity. Application: large conveyors and pump systems in heavy industry. Feature 2: Coil operating limits with a wide control voltage range of 24–60 V DC and built-in surge protection. Business impact: improves resilience to voltage fluctuations, lowers energy waste, and stabilizes control circuits. Application: factories with unstable or long control runs. Feature 3: Block-type design with easy add-on accessory blocks and compatibility with various auxiliary contact configurations. Business impact: scalable control architecture that grows with your automation needs, saving retrofit costs. Application: modular control panels and machine builds. Feature 4: Mechanical durability and electrical endurance rated at up to 3 million cycles and high breaking/making capacities. Business impact: long-term reliability and reduced maintenance; Application: high-cycle usage in packaging, material handling, and process lines. Feature 5: Robust standards and certifications including CE, UL/CSA, and UKCA along with IEC 60947-4-1 conformity. Business impact: regulatory confidence and smoother cross-border deployments. Application: global facilities requiring compliant power protection and control.
Get a Quick Quote for a ABB 1SFL617001R6811
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SFL617001R6811?
Enquire Now
FAQs
The AF580-30-11 is designed for 3-pole configurations with main circuit bars and pre-mounted auxiliary contacts. It fits standard panel layouts and supports 52 mm² copper or aluminum main conductors, making it straightforward to integrate into existing switchgear or new control panels while maintaining safe clearance and IP protection per IEC standards.
Key specs include a main circuit rated voltage of up to 1000 V, AC-3 rated current up to 580 A at various voltages, and DC coil operation from 24 to 60 V. The device supports a maximum motor power range up to 315 kW (380/400 V) and 500 kW (690 V), with a short-time withstand current suitable for controlled inrush events.
Yes. Designed for AC-3 duty, it delivers reliable motor starting for large drives, with rated operational current up to 580 A at 55°C and an 8x Ie breaking capacity. This makes it appropriate for high-load applications such as pumps and fans, while keeping switching losses and arcing under control in compliant networks.
The device carries CE and UL/CSA certifications, with UKCA labeling for compliant regions, plus a CE Declaration of Conformity and broader IEC 60947-4-1 compatibility. These certifications support cross-border deployments, supplier audits, and compliance with global electrical safety and performance standards in industrial facilities.
With 3 million mechanical cycles and robust surge protection, the AF580-30-11 minimizes maintenance downtime and parts replacement. Its modular design and accessory expandability reduce retrofits, improving lifecycle ROI through longer intervals between service, lower energy waste, and fewer panel reworks during upgrades.