ABB 1SFL637001R6922 Block Contactor - CE Certification
Part Number: 1SFL637001R6922
Quick Summary
Block Contactor is ABB AF technology for reliable motor control in industrial automation panels. This compact, high-current device accepts a wide control voltage range, reducing panel energy consumption while accommodating fluctuations in supply networks. It ships with built-in surge protection and pre-mounted auxiliary contacts, delivering a ready-to-install solution for demanding motor-start applications. The product carries CE, UL/CSA, and UKCA markings, plus RoHS and WEEE compliance, supporting global deployment. For panel builders and OEMs, the combination of robust ratings, ease of extension with add-on blocks, and tested accessories translates into faster installation, lower maintenance, and improved system uptime across diverse industrial environments.
Product Information
Extended Description
1SFL637001R6922 ABB: The AF750-30-22-69 is a 3 pole - 1000 V IEC or 600 V UL contactor with pre-mounted auxiliary contacts and Main Circuit Bars, controlling motors up to 400 kW / 400 V AC (AC-3) or 600 hp / 480 V UL and switching power circuits up to 1050 A (AC-1) or 900 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (48-130 V 50/60 Hz and DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100214C0202 - Main catalog Motor protection and control Manual motor starters, contactors and overload relays (PDF) - Edition 2024
Data Sheet, Technical Information (Part 2)
Contactors and Overload relays guide
Instructions and Manuals
1SFC380023-en
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Dimension Diagram
53540919-60
Product Net Width
210 mm
Product Net Depth / Length
242 mm
Product Net Height
283 mm
Product Net Weight
13.6 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
2
Number of Auxiliary Contacts NC
2
Number of Poles
3P
Rated Operational Voltage
Main Circuit 1000 V
Rated Frequency (f)
Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 1050 A
Rated Operational Current AC-1 (Ie)
(1000 V) 40 °C 1000 A | (1000 V) 55 °C 875 A | (1000 V) 70 °C 720 A | (690 V) 40 °C 1050 A | (690 V) 55 °C 875 A | (690 V) 70 °C 720 A
Rated Operational Current AC-3 (Ie)
(415 V) 55 °C 750 A | (440 V) 55 °C 750 A | (500 V) 55 °C 750 A | (690 V) 55 °C 650 A | (1000 V) 55 °C 300 A | (380 / 400 V) 55 °C 750 A | (220 / 230 / 240 V) 55 °C 750 A
Rated Operational Current DC-1 (Ie)
(110 V) 1-Pole, 40 °C 1050 A | (110 V) 2 Poles in Series, 40 °C 1050 A | (220 V) 3 Poles in Series, 40 °C 1050 A | (600 V) 3 Poles in Series, 40 °C 1050 A | (850 V) 3 Poles in Series, 40 °C 1050 A
Rated Operational Current DC-3 (Ie)
(110 V) 1-Pole, 40 °C 1050 A | (110 V) 2 Poles in Series, 40 °C 1050 A | (220 V) 3 Poles in Series, 40 °C 1050 A | (600 V) 3 Poles in Series, 40 °C 1050 A
Rated Operational Current DC-5 (Ie)
(110 V) 1-Pole, 40 °C 1050 A | (110 V) 2 Poles in Series, 40 °C 1050 A | (220 V) 3 Poles in Series, 40 °C 1050 A | (600 V) 3 Poles in Series, 40 °C 1050 A
Rated Operational Power AC-3 (Pe)
(415 V) 425 kW | (440 V) 450 kW | (500 V) 520 kW | (690 V) 600 kW | (1000 V) 400 kW | (380 / 400 V) 400 kW | (220 / 230 / 240 V) 220 kW
Rated Breaking Capacity AC-3
8 x Ie AC-3
Rated Making Capacity AC-3
10 x Ie AC-3
Short-Circuit Protective Devices
gG Type Fuses 1000 A
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 6400 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 1300 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 3500 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 7000 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 4500 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 7500 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 7000 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V | acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)
Main Circuit 8 kV
Maximum Electrical Switching Frequency
(AC-1) 300 cycles per hour | (AC-2 / AC-4) 60 cycles per hour | (AC-3) 300 cycles per hour
Mechanical Durability
3 million
Maximum Mechanical Switching Frequency
300 cycles per hour
Coil Operating Limits
(acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C)
Rated Control Circuit Voltage (Uc)
50 Hz 48 ... 130 V | 60 Hz 48 ... 130 V | DC Operation 48 ... 130 V
Coil Consumption
Holding at Max. Rated Control Circuit Voltage 50 Hz 12 V·A | Holding at Max. Rated Control Circuit Voltage 60 Hz 12 V·A | Holding at Max. Rated Control Circuit Voltage DC 5 V·A | Pull-in at Max. Rated Control Circuit Voltage 50 Hz 1100 V·A | Pull-in at Max. Rated Control Circuit Voltage 60 Hz 1100 V·A | Pull-in at Max. Rated Control Circuit Voltage DC 1020 V·A
Power Loss
at Rated Operating Conditions per Pole 50 W
Operate Time
Between Coil De-energization and NC Contact Closing 50 ... 70 ms | Between Coil De-energization and NO Contact Opening 53 ... 73 ms | Between Coil Energization and NC Contact Opening 45 ... 115 ms | Between Coil Energization and NO Contact Closing 50 ... 120 ms
Connecting Capacity Main Circuit
Bar 52 mm² | Rigid Al-Cable 3x185 mm² | Rigid Cu-Cable 300 mm²
Connecting Capacity Auxiliary Circuit
Flexible with Ferrule 2x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² | Flexible 1x0.75 ... 2.5 mm² | Solid 2 x 1 ... 4 mm² | Stranded 1 x 1 .... 4 mm²
Connecting Capacity
Bar 52 mm² | Rigid Al-Cable 3x185 mm² | Rigid Cu-Cable 300 mm²
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Tightening Torque
Cable Lug 45 N·m | Main Circuit 45 N·m
Terminal Type
Main Circuit: Bars
Product Name
Block Contactor
NEMA Size
7
Horsepower Rating NEMA
(230 V AC) Three Phase 300 Hp | (460 V AC) Three Phase 600 Hp | (575 V AC) Three Phase 600 Hp
Maximum Operating Voltage UL/CSA
Main Circuit 1000 V
General Use Rating UL/CSA
(1000 V AC) 900 A | (600 V AC) 900 A
Horsepower Rating UL/CSA
(200 V AC) Three Phase 250 hp | (208 V AC) Three Phase 250 hp | (220 ... 240 V AC) Three Phase 300 hp | (440 ... 480 V AC) Three Phase 600 hp | (550 ... 600 V AC) Three Phase 700 hp
Full Load Amps Motor Use
(440 ... 480 V AC) Three Phase 722 A | (550 ... 600 V AC) Three Phase 672 A
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °C | Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C | Close to Contactor for Storage -40 ... 70 °C
Maximum Operating Altitude Permissible
Without Derating 3000 m
Resistance to Shock acc. to IEC 60068-2-27
Shock Direction: A 5 g | Shock Direction: B1 5 g | Shock Direction: B2 5 g | Shock Direction: C1 5 g | Shock Direction: C2 5 g
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
End Of Life Disassembling Instructions
End-of-life instruction - AF(S)580(B)-**;AF(S)750(B)-**; AF750N7; AF1250(B)-**
Environmental Product Declaration - EPD
Environmental Product Declaration AF(S)580(F)(N), AF(S)750(F)(N), AF1250 (SE) Contactors
ABS Certificate
ABS Certificate, Contactor, AF400...AF2050 (Sweden)
BV Certificate
BV Certificate, Contactor, AF400 ... AF2850
CB Certificate
SE-82863
CCS Certificate
CCS Certificate, Contactor, AF116 to AF2850 (Sweden)
CQC Certificate
CQC Certificate, AC Contactor, AF580-30-*-*, AF750-30-*-* , AFS580-30-*-*, AFS750-30-*-*, Made in Sweden | CQC Certificate, Contactor, AF580, AF750, Made in China
CSA Certificate
306712-1
Declaration of Conformity - CCC
CCC Declaration of Conformity, AC Contactor, AF580-30-*-*, AF750-30-*-* , AFS580-30-*-*, AFS750-30-*-*, Made in Sweden | CCC Declaration of Conformity, Contactor, AF580, AF750, Made in China
Declaration of Conformity - CE
CE Declaration of Conformity - Contactor - AF400...AF2850
Declaration of Conformity - UKCA
UK Declaration of Conformity - Contactors >100A
DNV Certificate
DNV_E-10966
DNV GL Certificate
DNV Certificate, Contactor, AF400...AF2850
EAC Certificate
9AKK107046A8618
GL Certificate
GL_42988-02HH
LOVAG Certificate
SE-200439
LR Certificate
Lloyds register Certificate, Contactor, AF400...AF2850
PRS Certificate
PRS Certificate - AF116...AF1650
RINA Certificate
RINA Certificate, AF95, AF110, AF145, AF185, AF210, AF260, AF300, AF400, AF460, AF580, AF750, AF1250, AF1350, AF1650, AF2050, AF2650, AF116, AF140, AF146, AF190, AF205, AF265, AF305, AF370
RMRS Certificate
9AKK107045A6978
UL Certificate
cULus Certificate, Contactor, AF580, AF750, AFS580, AFS750
UL Listing Card
UL_E36588
Package Level 1 Units
box 1 piece
Package Level 1 Width
280 mm
Package Level 1 Depth / Length
375 mm
Package Level 1 Height
310 mm
Package Level 1 Gross Weight
15 kg
Package Level 1 EAN
7320500222065
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4758 >> Iec Contactors
Feature: Wide control circuit voltage range of 48-130 V AC/60 Hz, plus DC operation. Business Impact: Enables operation from variable power networks and reduces the need for multiple coil variants, cutting inventory and wiring complexity. Application: Motor starters for machines in manufacturing lines where supply voltage fluctuates. Feature: 3-pole main circuit with 2 auxiliary NO and 2 auxiliary NC contacts. Business Impact: Enhances control logic flexibility and allows integrated interlocking and signaling, improving safety and process control. Application: PLC-driven motor control panels requiring auxiliary feedback. Feature: Built-in surge protection and AF technology. Business Impact: Protects contacts from transients and extends service life, lowering maintenance costs and downtime. Application: Heavy-duty conveyors and milling equipment in automotive and packaging lines. Feature: Rated operational currents up to 1000 A AC-1 and up to 750 A AC-3 (at various voltages). Business Impact: Supports large motor loads and high-inertia starts without derating, improving line efficiency. Application: Large pumps, fans, and crushers in process industries. Feature: Pre-mounted main circuit bars and easy expandability with add-on blocks. Business Impact: Simplifies installation, reduces panel footprint, and accelerates commissioning in new builds or remodels. Application: OEM switchgear and machine builders needing modularity. Feature: International certifications (CE, UL/CSA, UKCA) and IP20 coil terminals/IP00 main terminals. Business Impact: Facilitates global compliance and safe installation in dusty environments, lowering regulatory risk. Application: Global manufacturing environments requiring standardization across sites.
Get a Quick Quote for a ABB 1SFL637001R6922
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SFL637001R6922?
Enquire Now
FAQs
The unit is designed for 48–130 V AC at 50/60 Hz and DC operation. Use the coil terminals for the control circuit, observe polarity for DC where required, and connect auxiliary contacts to the control logic to enable signaling and interlocking. Ensure proper torque on main and auxiliary terminals to maintain reliable operation.
AC-1 ratings reach up to 1000 A at 1000 V, with AC-3 ratings up to 750 A at voltages like 415–690 V depending on configuration. These ratings reflect the device’s capability to handle resistive and motor-load switching, ensuring reliable performance for common industrial motors.
Yes, it is engineered for robust industrial use with a mechanical durability of about 3 million cycles and a design that tolerates typical panel shocks and transients. The IP20 coil terminals and IP00 main terminals provide protection levels suitable for standard control enclosures in manufacturing settings.
The product carries CE and UKCA markings, UL/CSA compatibility, and RoHS/REACH compliance. This means it meets EU, UK, and North American safety and environmental standards, facilitating cross-border sales and regulatory compliance in diverse markets.
AF technology offers a wide control voltage range, reducing energy waste and panel heating due to voltage fluctuations. It also supports easy expansion with add-on auxiliary blocks and built-in surge protection, delivering lower maintenance costs and higher uptime in automated production lines.