ABB AF1250-30-00-68 Contactor - UL/CSA 1000 V

Part Number: 1SFL647001R6800
Manufacturer
ABB
Part number
1SFL647001R6800

Quick Summary

ABB AF1250-30-00-68 Contactor is a 3-pole power switch for motor control in manufacturing and process lines. When panel energy usage fluctuates and control voltages vary, reliability can suffer and energy waste can rise. It carries CE, UL/CSA listings, and RoHS/REACH compliance, ensuring global acceptance and regulatory alignment. Featuring AF technology and a wide 24–60 V DC coil operating range, this unit tolerates control voltage variations, reduces wasted energy, and supports stable operation in unstable networks. Its block design and compatibility with add-on auxiliary contact blocks simplify expansion, making it a future-proof choice for high-demand drives and automation architectures.

Product Information

Extended Description

1SFL647001R6800 ABB: The AF1250-30-00-68 is a 3 pole - 1000 V IEC or 600 V UL contactor with Main Circuit Bars, switching power circuits up to 1260 A (AC-1) or 1210 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (24-60 V DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100214C0202 - Main catalog Motor protection and control Manual motor starters, contactors and overload relays (PDF) - Edition 2024
Data Sheet, Technical Information (Part 2)
Contactors and Overload relays guide
Instructions and Manuals
1SFC380023-en
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
210 mm
Product Net Depth / Length
242 mm
Product Net Height
344 mm
Product Net Weight
14.6 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
0
Number of Auxiliary Contacts NC
0
Number of Poles
3P
Rated Operational Voltage
Main Circuit 1000 V
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 1050 A
Rated Operational Current AC-1 (Ie)
(1000 V) 40 °C 1260 A | (1000 V) 55 °C 1040 A | (1000 V) 70 °C 875 A | (690 V) 40 °C 1260 A | (690 V) 55 °C 1040 A | (690 V) 70 °C 875 A
Rated Operational Current DC-1 (Ie)
(220 V) 3 Poles in Series, 40 °C 1250 A | (600 V) 3 Poles in Series, 40 °C 1250 A | (850 V) 3 Poles in Series, 40 °C 1250 A
Rated Operational Current DC-3 (Ie)
(220 V) 3 Poles in Series, 40 °C 1250 A | (600 V) 3 Poles in Series, 40 °C 1250 A | (850 V) 3 Poles in Series, 40 °C 1250 A
Rated Operational Current DC-5 (Ie)
(220 V) 3 Poles in Series, 40 °C 1250 A | (600 V) 3 Poles in Series, 40 °C 1250 A | (850 V) 3 Poles in Series, 40 °C 1250 A
Rated Breaking Capacity AC-3
8 x Ie AC-3
Rated Making Capacity AC-3
10 x Ie AC-3
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 7200 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 1500 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 4000 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 8000 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 5200 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 7500 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 7000 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V | acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)
Main Circuit 8 kV
Maximum Electrical Switching Frequency
(AC-1) 300 cycles per hour
Mechanical Durability
0.5 million
Maximum Mechanical Switching Frequency
300 cycles per hour
Coil Operating Limits
(acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C)
Rated Control Circuit Voltage (Uc)
DC Operation 24 ... 60 V
Coil Consumption
Holding at Max. Rated Control Circuit Voltage 50 Hz 12 V·A | Holding at Max. Rated Control Circuit Voltage 60 Hz 12 V·A | Holding at Max. Rated Control Circuit Voltage DC 5.5 V·A | Pull-in at Max. Rated Control Circuit Voltage 50 Hz 780 V·A | Pull-in at Max. Rated Control Circuit Voltage 60 Hz 780 V·A | Pull-in at Max. Rated Control Circuit Voltage DC 785 V·A
Power Loss
at Rated Operating Conditions per Pole 80 W
Operate Time
Between Coil De-energization and NC Contact Closing 50 ... 70 ms | Between Coil De-energization and NO Contact Opening 53 ... 73 ms | Between Coil Energization and NC Contact Opening 45 ... 115 ms | Between Coil Energization and NO Contact Closing 50 ... 120 ms
Connecting Capacity Main Circuit
Bar 50 mm²
Connecting Capacity Auxiliary Circuit
Flexible with Ferrule 2x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² | Solid 2 x 1 ... 4 mm² | Stranded 2 x 1 .... 4 mm²
Connecting Capacity
Bar 50 mm²
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Connecting Terminals (delivered in open position) Main Poles
M 3.5 (+,-) pozidriv 2 screw with cable clamp
Tightening Torque
Cable Lug 45 N·m
Terminal Type
Main Circuit: Bars
Product Name
Block Contactor
Horsepower Rating NEMA
(230 V AC) Three Phase 300 Hp | (460 V AC) Three Phase 600 Hp | (575 V AC) Three Phase 600 Hp
Maximum Operating Voltage UL/CSA
Main Circuit 1000 V
General Use Rating UL/CSA
(1000 V AC) 1210 A
Ambient Air Temperature
Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C | Close to Contactor for Storage -40 ... 70 °C
Maximum Operating Altitude Permissible
Without Derating 3000 m
Resistance to Shock acc. to IEC 60068-2-27
Shock Direction: A 5 g | Shock Direction: B1 5 g | Shock Direction: B2 5 g | Shock Direction: C1 5 g | Shock Direction: C2 5 g
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
End Of Life Disassembling Instructions
End-of-life instruction - AF(S)580(B)-**;AF(S)750(B)-**; AF750N7; AF1250(B)-**
Environmental Product Declaration - EPD
Environmental Product Declaration AF(S)580(F)(N), AF(S)750(F)(N), AF1250 (SE) Contactors
ABS Certificate
ABS Certificate, Contactor, AF400...AF2050 (Sweden)
BV Certificate
BV Certificate, Contactor, AF400 ... AF2850
CB Certificate
SE-82865
CCS Certificate
CCS Certificate, Contactor, AF116 to AF2850 (Sweden)
CQC Certificate
CQC Certificate, Contactor, AF1250-30-*-*, Made in Sweden | CQC Certificate, Contactor, AF1250, Made in China
Declaration of Conformity - CCC
CCC Declaration of Conformity, Contactor, AF1250-30-*-*, Made in Sweden | CCC Declaration of Conformity, Contactor, AF1250, Made in China
Declaration of Conformity - CE
CE Declaration of Conformity - Contactor - AF400...AF2850
Declaration of Conformity - UKCA
UK Declaration of Conformity - Contactors >100A
DNV GL Certificate
DNV Certificate, Contactor, AF400...AF2850
EAC Certificate
9AKK107046A8618
LR Certificate
Lloyds register Certificate, Contactor, AF400...AF2850
PRS Certificate
PRS Certificate - AF116...AF1650
RINA Certificate
RINA Certificate, AF95, AF110, AF145, AF185, AF210, AF260, AF300, AF400, AF460, AF580, AF750, AF1250, AF1350, AF1650, AF2050, AF2650, AF116, AF140, AF146, AF190, AF205, AF265, AF305, AF370
RMRS Certificate
9AKK107045A6978
UL Certificate
cULus Certificate, Contactor, AF1250
UL Listing Card
UL_E73397
Package Level 1 Width
280 mm
Package Level 1 Depth / Length
375 mm
Package Level 1 Height
310 mm
Package Level 1 Gross Weight
16 kg
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
Feature: AF technology provides a wide control voltage range (24–60 V DC). Business Impact: minimizes control-voltage related misoperation and reduces panel energy waste. Application: ideal for motors and drives in facilities with fluctuating supply, improving reliability and energy efficiency. Feature: Main circuit bars rated for high current with 50 mm² capacity. Business Impact: supports switching of large motor loads (I e up to 1260 A AC-1 at 1000 V) with solid current carrying capability. Application: conveyors, pumps, and presses in heavy-industry environments. Feature: Built-in surge protection. Business Impact: protects control electronics and downstream devices, reducing repair costs and downtime. Application: automated production lines with variable load profiles and transient events. Feature: Modular block design with add-on auxiliary contact blocks compatibility. Business Impact: scalable I/O expansion without redesign, enabling phased automation upgrades. Application: complex motor control schemes requiring staged control circuits. Feature: Comprehensive electrical ratings (Ui 1000 V, Ie up to 1260 A, AC-3 duty). Business Impact: ensures regulatory compliance and equipment interoperability, lowering procurement risk. Application: standardization across multi-line applications in manufacturing plants. Feature: Robust mechanical durability and IP-rated components (coil terminals IP20, main terminals IP00). Business Impact: long service life in harsh environments with easier maintenance access. Application: factories, warehouses, and process facilities where reliability is critical.

Get a Quick Quote for a ABB 1SFL647001R6800

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SFL647001R6800? Enquire Now

FAQs

To install the AF1250-30-00-68, mount the unit on a suitable enclosure surface and connect main circuit conductors to the 50 mm² rated bars as specified. Tighten main terminal screws to 45 N·m and ensure coil wiring conforms to the 24–60 V DC range. Use the block-design mounting to add auxiliary contact blocks as needed for your control circuit, and verify IP20 protection on coil terminals for safe access. This setup supports straightforward panel integration and scalable control architecture.
In AC-1 service at 1000 V, the AF1250-30-00-68 handles up to 1260 A, with ratings adapting to higher ambient temperatures (1260 A at 40 °C, 1040 A at 55 °C, 875 A at 70 °C). It also supports UL/CSA general use ratings of 1210 A at 1000 V. These specifications enable reliable motor control for heavy loads while maintaining compliance with international standards.
Yes, the device is rated for operation from −40 °C to 70 °C ambient, with current ratings specified at 40, 55, and 70 °C. The coil operates within a 24–60 V DC range, and the contactor maintains performance across this temperature span. For applications near the upper limit, design margin should account for the 70 °C derating, ensuring continued reliability in hot facilities.
The AF1250-30-00-68 carries CE and UL/CSA listings, RoHS and REACH declarations, and multiple third-party certifications (ABS, BV, LR, UL, DNV GL, RINA, PRS, etc.). It also aligns with WEEE B2B category guidelines. These certifications facilitate global procurement, regulatory compliance, and safe use across diverse markets.
AF technology provides a wide control-voltage tolerance, reducing nuisance tripping and enabling stable operation despite control-voltage fluctuations. This translates to lower energy waste, fewer panel reworks, and improved drive availability. For OEMs and integrators, the compact block design and compatibility with add-on blocks simplify upgrades and maintenance in evolving automation architectures.