ABB AF1250-30-11-70 Block Contactor - UL 1210A
Part Number: 1SFL647001R7011
Quick Summary
The ABB AF1250-30-11-70 Block Contactor is a high-capacity switch for motor control in industrial power circuits. Engineers often face voltage fluctuations and panel energy waste, and this device tolerates a wide control voltage range (100–250 V AC/DC) to simplify wiring and stabilize operation in unstable networks. It carries CE conformity, UL/CSA General Use ratings, and IP20 protection on coil terminals (IP00 on main terminals), with RoHS and REACH compliance and an Environmental Product Declaration available. Its modular design supports add-on auxiliary contact blocks, enabling scalable protection and control while reducing total lifecycle costs for evolving automation needs.
Product Information
Extended Description
1SFL647001R7011 ABB: The AF1250-30-11-70 is a 3 pole - 1000 V IEC or 600 V UL contactor with pre-mounted auxiliary contacts and Main Circuit Bars, switching power circuits up to 1260 A (AC-1) or 1210 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (100-250 V 50/60 Hz and DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.
Lead Time
28 day
Made To Order
No
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
USSVCEXPU
Warranty Return
Product under warranty must be returned
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100214C0202 - Main catalog Motor protection and control Manual motor starters, contactors and overload relays (PDF) - Edition 2024
Data Sheet, Technical Information (Part 2)
Contactors and Overload relays guide
Instructions and Manuals
1SFC380023-en
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
210 mm
Product Net Depth / Length
242 mm
Product Net Height
344 mm
Product Net Weight
14.6 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
1
Number of Auxiliary Contacts NC
1
Number of Poles
3P
Rated Operational Voltage
Main Circuit 1000 V
Rated Frequency (f)
Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 1050 A
Rated Operational Current AC-1 (Ie)
(1000 V) 40 °C 1260 A | (1000 V) 55 °C 1040 A | (1000 V) 70 °C 875 A | (690 V) 40 °C 1260 A | (690 V) 55 °C 1040 A | (690 V) 70 °C 875 A
Rated Operational Current DC-1 (Ie)
(220 V) 3 Poles in Series, 40 °C 1250 A | (600 V) 3 Poles in Series, 40 °C 1250 A | (850 V) 3 Poles in Series, 40 °C 1250 A
Rated Operational Current DC-3 (Ie)
(220 V) 3 Poles in Series, 40 °C 1250 A | (600 V) 3 Poles in Series, 40 °C 1250 A | (850 V) 3 Poles in Series, 40 °C 1250 A
Rated Operational Current DC-5 (Ie)
(220 V) 3 Poles in Series, 40 °C 1250 A | (600 V) 3 Poles in Series, 40 °C 1250 A | (850 V) 3 Poles in Series, 40 °C 1250 A
Rated Breaking Capacity AC-3
8 x Ie AC-3
Rated Making Capacity AC-3
10 x Ie AC-3
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 7200 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 1500 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 4000 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 8000 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 5200 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 7500 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 7000 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V | acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)
Main Circuit 8 kV
Maximum Electrical Switching Frequency
(AC-1) 300 cycles per hour
Mechanical Durability
0.5 million
Maximum Mechanical Switching Frequency
300 cycles per hour
Coil Operating Limits
(acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C)
Rated Control Circuit Voltage (Uc)
50 Hz 100 ... 250 V | 60 Hz 100 ... 250 V | DC Operation 100 ... 250 V
Coil Consumption
Holding at Max. Rated Control Circuit Voltage 50 Hz 12 V·A | Holding at Max. Rated Control Circuit Voltage 60 Hz 12 V·A | Holding at Max. Rated Control Circuit Voltage DC 5 V·A | Pull-in at Max. Rated Control Circuit Voltage 50 Hz 880 V·A | Pull-in at Max. Rated Control Circuit Voltage 60 Hz 880 V·A | Pull-in at Max. Rated Control Circuit Voltage DC 880 V·A
Power Loss
at Rated Operating Conditions per Pole 80 W
Operate Time
Between Coil De-energization and NC Contact Closing 50 ... 70 ms | Between Coil De-energization and NO Contact Opening 53 ... 73 ms | Between Coil Energization and NC Contact Opening 45 ... 115 ms | Between Coil Energization and NO Contact Closing 50 ... 120 ms
Connecting Capacity Main Circuit
Bar 50 mm²
Connecting Capacity Auxiliary Circuit
Flexible with Ferrule 2x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm² | Flexible 2x0.75 ... 2.5 mm² | Solid 2 x 1 ... 4 mm² | Stranded 1 x 1 .... 4 mm²
Connecting Capacity
Bar 50 mm²
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Connecting Terminals (delivered in open position) Main Poles
M 3.5 (+,-) pozidriv 2 screw with cable clamp
Tightening Torque
Cable Lug 45 N·m
Terminal Type
Main Circuit: Bars
Product Name
Block Contactor
Horsepower Rating NEMA
(230 V AC) Three Phase 300 Hp | (460 V AC) Three Phase 600 Hp | (575 V AC) Three Phase 600 Hp
Maximum Operating Voltage UL/CSA
Main Circuit 1000 V
General Use Rating UL/CSA
(1000 V AC) 1210 A
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °C | Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C | Close to Contactor for Storage -40 ... 70 °C
Maximum Operating Altitude Permissible
Without Derating 3000 m
Resistance to Shock acc. to IEC 60068-2-27
Shock Direction: A 5 g | Shock Direction: B1 5 g | Shock Direction: B2 5 g | Shock Direction: C1 5 g | Shock Direction: C2 5 g
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
End Of Life Disassembling Instructions
End-of-life instruction - AF(S)580(B)-**;AF(S)750(B)-**; AF750N7; AF1250(B)-**
Environmental Product Declaration - EPD
Environmental Product Declaration AF(S)580(F)(N), AF(S)750(F)(N), AF1250 (SE) Contactors
ABS Certificate
ABS Certificate, Contactor, AF400...AF2050 (Sweden)
BV Certificate
BV Certificate, Contactor, AF400 ... AF2850
CB Certificate
SE-82865
CCS Certificate
CCS Certificate, Contactor, AF116 to AF2850 (Sweden)
CQC Certificate
CQC Certificate, Contactor, AF1250-30-*-*, Made in Sweden | CQC Certificate, Contactor, AF1250, Made in China
Declaration of Conformity - CCC
CCC Declaration of Conformity, Contactor, AF1250-30-*-*, Made in Sweden | CCC Declaration of Conformity, Contactor, AF1250, Made in China
Declaration of Conformity - CE
CE Declaration of Conformity - Contactor - AF400...AF2850
Declaration of Conformity - UKCA
UK Declaration of Conformity - Contactors >100A
DNV GL Certificate
DNV Certificate, Contactor, AF400...AF2850
EAC Certificate
9AKK107046A8618
LR Certificate
Lloyds register Certificate, Contactor, AF400...AF2850
PRS Certificate
PRS Certificate - AF116...AF1650
RINA Certificate
RINA Certificate, AF95, AF110, AF145, AF185, AF210, AF260, AF300, AF400, AF460, AF580, AF750, AF1250, AF1350, AF1650, AF2050, AF2650, AF116, AF140, AF146, AF190, AF205, AF265, AF305, AF370
RMRS Certificate
9AKK107045A6978
UL Certificate
cULus Certificate, Contactor, AF1250
UL Listing Card
UL_E73397
Package Level 1 Units
box 1 piece
Package Level 1 Width
280 mm
Package Level 1 Depth / Length
375 mm
Package Level 1 Height
310 mm
Package Level 1 Gross Weight
16 kg
Package Level 1 EAN
7320500355091
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4758 >> Iec Contactors
E-Number (Finland)
3709324
E-Number (Norway)
4115382
E-Number (Sweden)
4115382
Feature: Wide control voltage range 100–250 V AC/DC enables compatibility with variable supply conditions, reducing control wiring and panel energy waste. Business impact: lowers wiring complexity, improves energy efficiency, and enhances reliability in fluctuating networks. Application: motor control panels with diverse supply conditions. Feature: Built-in surge protection safeguards downstream electronics and contact reliability, increasing line uptime. Business impact: reduces maintenance costs and costly downtime. Application: demanding industrial environments. Feature: AF technology with a block-type, extensible design supports add-on auxiliary contact blocks for scalable protection. Business impact: supports future expansion without a full replacement. Application: modular motor protection schemes. Feature: High main-current capability (Ie up to 1260 A AC-1 at 40 °C; 1250 A DC-1/3) ensures suitability for large motors. Business impact: enables compact, single-device motor control for heavy machinery. Application: heavy industry drives. Feature: Coil consumption and operating limits optimize energy use (Holding 12 VA; Pull-in 880 VA; 0.85–1.1 Uc). Business impact: reduced control power and improved reliability in thermal environments. Application: long-term panel energy management. Feature: Mechanical durability and switching capacity (0.5 million cycles; 300 cycles/hr; Icw up to 8000 A). Business impact: longer service life and predictable maintenance windows. Application: high-cycle motor control. Feature: Protection and compliance (IP20 coil terminals; IP00 main terminals; CE, UL/CSA; RoHS/REACH). Business impact: simplifies regulatory approvals and supports global procurement. Application: multinational manufacturing environments.
Get a Quick Quote for a ABB 1SFL647001R7011
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SFL647001R7011?
Enquire Now
FAQs
The AF1250-30-11-70 features a modular, block-type design with mains terminals rated for Bar 50 mm² connections and compatible auxiliary contact blocks. The coil terminals are protected IP20, while main terminals are IP00, enabling straightforward panel mounting and secure wiring. It is designed for easy integration with existing ABB accessories and standardized installation practices.
In AC-1 applications at 1000 V, the contactor delivers up to 1260 A at 40 °C and 1040 A at 55 °C with 70 °C, and up to 1250 A in DC-1/3 configurations at 40 °C. This makes it suitable for demanding motor starting and load switching, providing reliable operation during surges and short transients while maintaining control circuit stability.
Yes. It features a wide control voltage range (100–250 V AC/DC) and built-in surge protection, which dampens voltage variations and protects the control circuit as well as downstream devices. The device is designed for 50/60 Hz operation and can help reduce nuisance tripping and energy waste in unstable networks.
The AF1250-30-11-70 comes with CE Declaration of Conformity, UL/CSA General Use ratings, UL certificates/listings, and RoHS/REACH compliance. It is also supported by product declarations and EPDs, aiding regulatory approvals for global procurement and multi-region deployments.
ROI improves through reduced control power consumption (holding 12 VA; pull-in 880 VA) and energy management benefits from the wide control voltage range, allowing fewer wiring conversions and simpler panel designs. The device’s modularity enables scalable protection with add-on auxiliary blocks, lowering replacement costs and extending service life in high-demand automation environments.