ABB AF1250-30-22-71 Block Contactor - CE, UL
Part Number: 1SFL647001R7122
Quick Summary
ABB AF1250-30-22-71 block contactor is designed to switch heavy motor loads in demanding industrial drives. In panels where control voltage fluctuates and outages threaten uptime, the wide 250–500 V AC/DC coil range and built-in surge protection help reduce nuisance tripping and improve reliability. The device carries CE, UL (general use) and UKCA certifications, reinforcing global compliance for multinational projects, while offering strong insulation and protective features. Its compact block design, pre-mounted auxiliary contacts, and broad accessory ecosystem simplify installation, reduce panel size, and lower total cost of ownership for panel builders and machine integrators. This combination of rugged performance and practical design supports efficient, safe and future-ready automation installations.
Product Information
Extended Description
1SFL647001R7122 ABB: The AF1250-30-22-71 is a 3 pole - 1000 V IEC or 600 V UL contactor with pre-mounted auxiliary contacts and Main Circuit Bars, switching power circuits up to 1260 A (AC-1) or 1210 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (250-500 V 50/60 Hz and DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100214C0202 - Main catalog Motor protection and control Manual motor starters, contactors and overload relays (PDF) - Edition 2024
Data Sheet, Technical Information (Part 2)
Contactors and Overload relays guide
Instructions and Manuals
1SFC380023-en
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
210 mm
Product Net Depth / Length
242 mm
Product Net Height
344 mm
Product Net Weight
14.6 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
2
Number of Auxiliary Contacts NC
2
Number of Poles
3P
Rated Operational Voltage
Main Circuit 1000 V
Rated Frequency (f)
Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 1050 A
Rated Operational Current AC-1 (Ie)
(1000 V) 40 °C 1260 A | (1000 V) 55 °C 1040 A | (1000 V) 70 °C 875 A | (690 V) 40 °C 1260 A | (690 V) 55 °C 1040 A | (690 V) 70 °C 875 A
Rated Operational Current DC-1 (Ie)
(220 V) 3 Poles in Series, 40 °C 1250 A | (600 V) 3 Poles in Series, 40 °C 1250 A | (850 V) 3 Poles in Series, 40 °C 1250 A
Rated Operational Current DC-3 (Ie)
(220 V) 3 Poles in Series, 40 °C 1250 A | (600 V) 3 Poles in Series, 40 °C 1250 A | (850 V) 3 Poles in Series, 40 °C 1250 A
Rated Operational Current DC-5 (Ie)
(220 V) 3 Poles in Series, 40 °C 1250 A | (600 V) 3 Poles in Series, 40 °C 1250 A | (850 V) 3 Poles in Series, 40 °C 1250 A
Rated Breaking Capacity AC-3
8 x Ie AC-3
Rated Making Capacity AC-3
10 x Ie AC-3
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 7200 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 1500 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 4000 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 8000 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 5200 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 7500 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 7000 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V | acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)
Main Circuit 8 kV
Maximum Electrical Switching Frequency
(AC-1) 300 cycles per hour
Mechanical Durability
0.5 million
Maximum Mechanical Switching Frequency
300 cycles per hour
Coil Operating Limits
(acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C)
Rated Control Circuit Voltage (Uc)
50 Hz 250 ... 500 V | 60 Hz 250 ... 500 V | DC Operation 250 ... 500 V
Coil Consumption
Holding at Max. Rated Control Circuit Voltage 50 Hz 12 V·A | Holding at Max. Rated Control Circuit Voltage 60 Hz 12 V·A | Holding at Max. Rated Control Circuit Voltage DC 7.5 V·A | Pull-in at Max. Rated Control Circuit Voltage 50 Hz 985 V·A | Pull-in at Max. Rated Control Circuit Voltage 60 Hz 985 V·A | Pull-in at Max. Rated Control Circuit Voltage DC 910 V·A
Power Loss
at Rated Operating Conditions per Pole 80 W
Operate Time
Between Coil De-energization and NC Contact Closing 50 ... 70 ms | Between Coil De-energization and NO Contact Opening 53 ... 73 ms | Between Coil Energization and NC Contact Opening 45 ... 115 ms | Between Coil Energization and NO Contact Closing 50 ... 120 ms
Connecting Capacity Main Circuit
Bar 50 mm²
Connecting Capacity Auxiliary Circuit
Flexible with Ferrule 2x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² | Flexible 2x0.75 ... 2.5 mm² | Solid 2 x 1 ... 4 mm² | Stranded 2 x 1 .... 4 mm²
Connecting Capacity
Bar 50 mm²
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Connecting Terminals (delivered in open position) Main Poles
M 3.5 (+,-) pozidriv 2 screw with cable clamp
Tightening Torque
Cable Lug 45 N·m
Terminal Type
Main Circuit: Bars
Product Name
Block Contactor
Horsepower Rating NEMA
(230 V AC) Three Phase 300 Hp | (460 V AC) Three Phase 600 Hp | (575 V AC) Three Phase 600 Hp
Maximum Operating Voltage UL/CSA
Main Circuit 1000 V
General Use Rating UL/CSA
(1000 V AC) 1210 A
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °C | Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C | Close to Contactor for Storage -40 ... 70 °C
Maximum Operating Altitude Permissible
Without Derating 3000 m
Resistance to Shock acc. to IEC 60068-2-27
Shock Direction: A 5 g | Shock Direction: B1 5 g | Shock Direction: B2 5 g | Shock Direction: C1 5 g | Shock Direction: C2 5 g
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
End Of Life Disassembling Instructions
End-of-life instruction - AF(S)580(B)-**;AF(S)750(B)-**; AF750N7; AF1250(B)-**
Environmental Product Declaration - EPD
Environmental Product Declaration AF(S)580(F)(N), AF(S)750(F)(N), AF1250 (SE) Contactors
ABS Certificate
ABS Certificate, Contactor, AF400...AF2050 (Sweden)
BV Certificate
BV Certificate, Contactor, AF400 ... AF2850
CB Certificate
SE-82865
CCS Certificate
CCS Certificate, Contactor, AF116 to AF2850 (Sweden)
CQC Certificate
CQC Certificate, Contactor, AF1250-30-*-*, Made in Sweden | CQC Certificate, Contactor, AF1250, Made in China
Declaration of Conformity - CCC
CCC Declaration of Conformity, Contactor, AF1250-30-*-*, Made in Sweden | CCC Declaration of Conformity, Contactor, AF1250, Made in China
Declaration of Conformity - CE
CE Declaration of Conformity - Contactor - AF400...AF2850
Declaration of Conformity - UKCA
UK Declaration of Conformity - Contactors >100A
DNV GL Certificate
DNV Certificate, Contactor, AF400...AF2850
EAC Certificate
9AKK107046A8618
LR Certificate
Lloyds register Certificate, Contactor, AF400...AF2850
PRS Certificate
PRS Certificate - AF116...AF1650
RINA Certificate
RINA Certificate, AF95, AF110, AF145, AF185, AF210, AF260, AF300, AF400, AF460, AF580, AF750, AF1250, AF1350, AF1650, AF2050, AF2650, AF116, AF140, AF146, AF190, AF205, AF265, AF305, AF370
RMRS Certificate
9AKK107045A6978
UL Certificate
cULus Certificate, Contactor, AF1250
UL Listing Card
UL_E73397
Package Level 1 Units
box 1 piece
Package Level 1 Width
280 mm
Package Level 1 Depth / Length
375 mm
Package Level 1 Height
310 mm
Package Level 1 Gross Weight
16 kg
Package Level 1 EAN
7320500355121
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4758 >> Iec Contactors
Feature → Business Impact → Application: The AF1250-30-22-71 provides a wide control voltage range of 250–500 V for AC and DC operation, which minimizes panel wiring variations and reduces energy waste during voltage fluctuations, boosting overall efficiency in motor control applications. This translates to lower operating costs and more stable equipment performance in variable-network settings, such as packaging lines or material handling systems. Feature → Business Impact → Application: Three main contacts (NO) plus two NO and two NC auxiliary contacts enable flexible control logic and status feedback, improving fault diagnosis and control accuracy in centralized automation panels. Use this in conveyor drives and fan/pump packages where monitoring auxiliary states lowers downtime. Feature → Business Impact → Application: Built-in surge protection and a robust insulation rating (1000 V) deliver enhanced reliability in harsh industrial environments, enabling longer service intervals and reduced maintenance expenses in steel mills, water treatment facilities, and process lines. Feature → Business Impact → Application: Pre-mounted Main Circuit Bars and 50 mm² connecting capacity streamline installation, reduce field wiring errors, and save assembly time in large switchgear assemblies. Feature → Business Impact → Application: Block-type design offers easy extendability with add-on auxiliary contact blocks, supporting scalable control architectures for future line upgrades or modular panel expansions without disruptive rewiring.
Get a Quick Quote for a ABB 1SFL647001R7122
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SFL647001R7122?
Enquire Now
FAQs
Install the unit using the provided main circuit bars rated for 50 mm² conductors and mount it so that the coil terminals are accessible for control wiring. Use M3.5 (+,-) Pozidriv screws with cable clamps and tighten to 45 N·m. Ensure adequate clearance and verify IP20 protection on coil terminals during wiring and commissioning.
The 250-500 V range supports both 50/60 Hz AC and DC operation, accommodating variations in control supply without nuisance tripping. This reduces panel energy waste, stabilizes control signals in networks with voltage fluctuations, and enables reliable operation of drives and contactor logic across diverse international installations.
Yes. The AF1250-30-22-71 carries CE and UL certifications, with additional declarations such as UKCA and UL listing cards where applicable. This ensures compatibility with global safety and performance standards, making it suitable for international projects, OEM integrations, and certified panel builds.
The contactor provides an AC-3 rating of 8 x Ie and a DC-1/DC-3/DC-5 rating of 1250 A at various voltages, enabling reliable starting and switching of motor loads with high inrush. Selection should account for the motor’s full-load current, voltage class, and the duty cycle to ensure the device remains within its rated switching capacity.
Plan for periodic inspections of main and auxiliary terminations, verify tightness on M3.5 screws (45 N·m), and monitor coil temperature limits (0.85–1.1 Uc). With a mechanical durability of about 0.5 million cycles, and IP20 coil terminals, maintain enclosure integrity and clean connections to prevent contamination-induced wear and ensure consistent performance.