ABB 1SFL647033R7011 Block Contactor - 1140 V
Part Number: 1SFL647033R7011
Quick Summary
ABB 1SFL647033R7011 Block Contactor provides three-pole motor switching for wind and solar power systems. A common pain point is achieving high current handling while keeping installation footprint small and serviceable. This device addresses that by delivering a 3P main circuit up to 1140 V, a wide control voltage range of 100–250 V AC/DC, and reliable auxiliary contacts for control logic. It meets IEC 60947-4-1 and features CE, UL/CSA, and UKCA certifications, along with RoHS and REACH declarations, supporting global procurement and compliance programs. For engineers, the result is streamlined panel design, predictable lifecycle costs, and accelerated commissioning in renewable energy plants and industrial drives, backed by ABB’s reliability in heavy-duty motor control.
Product Information
Extended Description
1SFL647033R7011 ABB: A 3-phase Contactor suitable for power generation applications in renewable energy segment up to max 1140 V. Operated with wide control voltage range 100-250 V, AC/DC
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100214C0202 - Main catalog Motor protection and control Manual motor starters, contactors and overload relays (PDF) - Edition 2024
Data Sheet, Technical Information (Part 2)
Contactors and Overload relays guide
Instructions and Manuals
1SFC380023-en
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Dimension Diagram
53540919-60
Product Net Width
210 mm
Product Net Depth / Length
242 mm
Product Net Height
344 mm
Product Net Weight
14.6 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
1
Number of Auxiliary Contacts NC
1
Number of Poles
3P
Rated Operational Voltage
Main Circuit 1140 V
Rated Frequency (f)
Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 1050 A
Rated Operational Current AC-1 (Ie)
(1000 V) 40 °C 1260 A | (1000 V) 55 °C 1040 A | (1000 V) 70 °C 875 A | (690 V) 40 °C 1260 A | (690 V) 55 °C 1040 A | (690 V) 70 °C 875 A | (1140 V) 40 °C 1260 A
Rated Operational Current DC-1 (Ie)
(220 V) 3 Poles in Series, 40 °C 1250 A | (600 V) 3 Poles in Series, 40 °C 1250 A | (850 V) 3 Poles in Series, 40 °C 1250 A
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 7200 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 1500 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 4000 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 8000 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 5200 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 7500 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 7000 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1140 V | acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)
Main Circuit 8 kV
Maximum Electrical Switching Frequency
(AC-1) 300 cycles per hour
Mechanical Durability
0.5 million
Maximum Mechanical Switching Frequency
300 cycles per hour
Coil Operating Limits
(acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C)
Rated Control Circuit Voltage (Uc)
50 Hz 100 ... 250 V | 60 Hz 100 ... 250 V | DC Operation 100 ... 250 V
Coil Consumption
Holding at Max. Rated Control Circuit Voltage 50 Hz 12 V·A | Holding at Max. Rated Control Circuit Voltage 60 Hz 12 V·A | Holding at Max. Rated Control Circuit Voltage DC 5 V·A | Pull-in at Max. Rated Control Circuit Voltage 50 Hz 880 V·A | Pull-in at Max. Rated Control Circuit Voltage 60 Hz 880 V·A | Pull-in at Max. Rated Control Circuit Voltage DC 880 V·A
Power Loss
at Rated Operating Conditions per Pole 80 W
Operate Time
Between Coil De-energization and NC Contact Closing 50 ... 70 ms | Between Coil De-energization and NO Contact Opening 53 ... 73 ms | Between Coil Energization and NC Contact Opening 45 ... 115 ms | Between Coil Energization and NO Contact Closing 50...120 ms
Connecting Capacity Main Circuit
Bar 50 mm²
Connecting Capacity Auxiliary Circuit
Flexible with Ferrule 2x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm² | Flexible 2x0.75 ... 2.5 mm² | Solid 2 x 1 ... 4 mm² | Stranded 1 x 1 .... 4 mm²
Connecting Capacity
Bar 50 mm²
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Tightening Torque
Cable Lug 45 N·m
Terminal Type
Main Circuit: Bars
Product Name
Block Contactor
Maximum Operating Voltage UL/CSA
Main Circuit 1000 V
General Use Rating UL/CSA
(1000 V AC) 1210 A
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °C | Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C | Close to Contactor for Storage -40 ... 70 °C
Maximum Operating Altitude Permissible
Without Derating 3000 m
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
End Of Life Disassembling Instructions
End-of-life instruction - AF(S)580(B)-**;AF(S)750(B)-**; AF750N7; AF1250(B)-**
Environmental Product Declaration - EPD
Environmental Product Declaration AF(S)580(F)(N), AF(S)750(F)(N), AF1250 (SE) Contactors
CB Certificate
SE-82865
CCS Certificate
CCS Certificate, Contactor, AF116 to AF2850 (Sweden)
CQC Certificate
CQC Certificate, Contactor, AF1250-30-*-*, Made in Sweden | CQC Certificate, Contactor, AF1250, Made in China
Declaration of Conformity - CCC
CCC Declaration of Conformity, Contactor, AF1250-30-*-*, Made in Sweden | CCC Declaration of Conformity, Contactor, AF1250, Made in China
Declaration of Conformity - CE
CE Declaration of Conformity - Contactor - AF400...AF2850
Declaration of Conformity - UKCA
UK Declaration of Conformity - Contactors >100A
EAC Certificate
9AKK107046A8618
LR Certificate
Lloyds register Certificate, Contactor, AF400...AF2850
UL Certificate
cULus Certificate, Contactor, AF1250
Package Level 1 Units
box 1 piece
Package Level 1 Width
280 mm
Package Level 1 Depth / Length
375 mm
Package Level 1 Height
310 mm
Package Level 1 Gross Weight
16 kg
Package Level 1 EAN
7320500541722
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
Feature: Three-pole block contactor with three main normally open contacts and one normally open plus one normally closed auxiliary contact. Business Impact: Enables compact, high-current motor control in a single device, reducing panel density and wiring complexity. Application: Ideal for wind turbine drive systems and large industrial motors where space and reliability matter. Feature: Wide control circuit compatibility from 100 to 250 V across AC, 60 Hz, and DC operation. Business Impact: Simplifies integration with existing control architectures and stock management, cutting engineering time and part variety. Application: Suitable for OEM machinery, solar inverters, and automated lines that rely on versatile coil inputs. Feature: High insulation and voltage ratings with 1140 V Ui and 50/60 Hz operating frequency. Business Impact: Supports grid-compatible motor control and long-term insulation reliability in demanding environments. Application: Renewable energy interfaces and heavy-duty drives that require robust voltage margins. Feature: High breaking and withstand currents (up to 7500 A at 440 V and 7000 A at 690 V). Business Impact: Reduces the need for simultaneous protective devices and minimizes startup transients, boosting uptime. Application: Start-stop routines for large motors in mining, processing, and processing plants. Feature: Mechanical durability rated at 0.5 million cycles and substantial connection capacity (50 mm² main, 2x 0.75–2.5 mm² aux). Business Impact: Longer service life with lower maintenance costs and flexible wiring options for panel builders. Application: Routine fault-tolerant installations in harsh environments where lifecycle ROI matters. Feature: Protection ratings (coil IP20, main IP00) and rugged enclosure dimensions. Business Impact: Safer wiring and simplified mounting in controlled facilities; predictable footprint for cabinet layouts. Application: Factory automation panels, distributed control rooms, and outdoor-friendly enclosures where IP protection is required. Feature: Compliance and certifications including CE, UL/CSA, UKCA, RoHS, and REACH. Business Impact: Regulatory readiness across regions, simplifying procurement and audit processes. Application: Global deployments in wind/solar farms, water treatment, and large-scale conveyors with strict compliance needs.
Get a Quick Quote for a ABB 1SFL647033R7011
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SFL647033R7011?
Enquire Now
FAQs
Install the unit in a suitable panel with room for the 210×242×344 mm enclosure. Attach the main circuit conductors to Bar 50 mm² terminals and secure auxiliary wiring to the 2x0.75–2.5 mm² or equivalent terminals. Torque the cable lugs to 45 N·m and verify IP20 protection for coil wiring. Ensure control voltage is within 100–250 V AC/DC and confirm 50/60 Hz operation per the datasheet. Proper mounting and clean wiring reduce heat build-up and improve reliability.
The coil accepts AC at 50/60 Hz and DC, enabling seamless integration with existing PLCs, relays, or motor starters without requiring a separate interface module. This flexibility simplifies procurement, reduces stock variety, and accelerates commissioning in both wind turbine drives and solar inverter applications, while maintaining consistent pull-in and holding characteristics across voltages.
Yes. The device supports a main circuit rated up to 1140 V with 50/60 Hz operation, plus high short-time withstand and breaking capacities suitable for startup surges common in renewable energy drives. Its wide operating temperature range and altitude tolerance without derating up to 3000 m fit outdoor and plant environments, while CE, UL/CSA, and UKCA certifications ensure regulatory alignment across regions.
Key certifications include CE for European conformity, UL/CSA for North American safety, and UKCA for UK compliance, plus RoHS/REACH declarations. These confirm electrical safety, environmental compliance, and interoperability with global supply chains, reducing risk during audits and enabling smoother cross-border procurement and installation.
With a mechanical durability rating of 0.5 million cycles and solid connection capabilities, the unit offers long service life and reduced maintenance frequency. The compact footprint and reliable high-current switching contribute to lower total cost of ownership by minimizing panel space, simplifying wiring, and reducing downtime in renewable energy plants and heavy industry drives.