ABB 1SFL647033R7022 Contactor - CE UL Rated 1140V
Part Number: 1SFL647033R7022
Quick Summary
ABB 1SFL647033R7022 Contactor is a high-current, three-pole control device designed for demanding electrical protection and control in power generation and heavy equipment. It offers a wide control voltage range of 100-250 V AC/DC, simplifying installation and stocking across projects. This block contactor is rated for mains up to 1140 V and supports 50/60 Hz, making it suitable for renewable energy inverters, motors, and process lines. The product carries key certifications including CE, UL/CSA, and UKCA, with IP20 coil terminals and IP00 main terminals to support safe operation in industrial environments. By selecting ABB, you gain reliable performance, straightforward maintenance, and a scalable solution that aligns with broader ABB automation portfolios and service ecosystems.
Product Information
Extended Description
1SFL647033R7022 ABB: A 3-phase Contactor suitable for power generation applications in renewable energy segment up to max 1140 V. Operated with wide control voltage range 100-250 V, AC/DC
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100214C0202 - Main catalog Motor protection and control Manual motor starters, contactors and overload relays (PDF) - Edition 2024
Data Sheet, Technical Information (Part 2)
Contactors and Overload relays guide
Instructions and Manuals
1SFC380023-en
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Dimension Diagram
53540919-60
Product Net Width
210 mm
Product Net Depth / Length
242 mm
Product Net Height
344 mm
Product Net Weight
14.6 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
2
Number of Auxiliary Contacts NC
2
Number of Poles
3P
Rated Operational Voltage
Main Circuit 1140 V
Rated Frequency (f)
Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 1050 A
Rated Operational Current AC-1 (Ie)
(1000 V) 40 °C 1260 A | (1000 V) 55 °C 1040 A | (1000 V) 70 °C 875 A | (690 V) 40 °C 1260 A | (690 V) 55 °C 1040 A | (690 V) 70 °C 875 A | (1140 V) 40 °C 1260 A
Rated Operational Current DC-1 (Ie)
(220 V) 3 Poles in Series, 40 °C 1250 A | (600 V) 3 Poles in Series, 40 °C 1250 A | (850 V) 3 Poles in Series, 40 °C 1250 A
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 7200 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 1500 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 4000 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 8000 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 5200 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 7500 A | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 7000 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1140 V | acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)
Main Circuit 8 kV
Maximum Electrical Switching Frequency
(AC-1) 300 cycles per hour
Mechanical Durability
0.5 million
Maximum Mechanical Switching Frequency
300 cycles per hour
Coil Operating Limits
(acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C)
Rated Control Circuit Voltage (Uc)
50 Hz 100 ... 250 V | 60 Hz 100 ... 250 V | DC Operation 100 ... 250 V
Coil Consumption
Holding at Max. Rated Control Circuit Voltage 50 Hz 12 V·A | Holding at Max. Rated Control Circuit Voltage 60 Hz 12 V·A | Holding at Max. Rated Control Circuit Voltage DC 5 V·A | Pull-in at Max. Rated Control Circuit Voltage 50 Hz 880 V·A | Pull-in at Max. Rated Control Circuit Voltage 60 Hz 880 V·A | Pull-in at Max. Rated Control Circuit Voltage DC 880 V·A
Power Loss
at Rated Operating Conditions per Pole 80 W
Operate Time
Between Coil De-energization and NC Contact Closing 50 ... 70 ms | Between Coil De-energization and NO Contact Opening 53 ... 73 ms | Between Coil Energization and NC Contact Opening 45 ... 115 ms | Between Coil Energization and NO Contact Closing 50...120 ms
Connecting Capacity Main Circuit
Bar 50 mm²
Connecting Capacity Auxiliary Circuit
Flexible with Ferrule 2x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm² | Flexible 2x0.75 ... 2.5 mm² | Solid 2 x 1 ... 4 mm² | Stranded 1 x 1 .... 4 mm²
Connecting Capacity
Bar 50 mm²
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Tightening Torque
Cable Lug 45 N·m
Terminal Type
Main Circuit: Bars
Product Name
Block Contactor
Maximum Operating Voltage UL/CSA
Main Circuit 1000 V
General Use Rating UL/CSA
(1000 V AC) 1210 A
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °C | Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C | Close to Contactor for Storage -40 ... 70 °C
Maximum Operating Altitude Permissible
Without Derating 3000 m
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
End Of Life Disassembling Instructions
End-of-life instruction - AF(S)580(B)-**;AF(S)750(B)-**; AF750N7; AF1250(B)-**
Environmental Product Declaration - EPD
Environmental Product Declaration AF(S)580(F)(N), AF(S)750(F)(N), AF1250 (SE) Contactors
CB Certificate
SE-82865
CCS Certificate
CCS Certificate, Contactor, AF116 to AF2850 (Sweden)
CQC Certificate
CQC Certificate, Contactor, AF1250-30-*-*, Made in Sweden | CQC Certificate, Contactor, AF1250, Made in China
Declaration of Conformity - CCC
CCC Declaration of Conformity, Contactor, AF1250-30-*-*, Made in Sweden | CCC Declaration of Conformity, Contactor, AF1250, Made in China
Declaration of Conformity - CE
CE Declaration of Conformity - Contactor - AF400...AF2850
Declaration of Conformity - UKCA
UK Declaration of Conformity - Contactors >100A
EAC Certificate
9AKK107046A8618
LR Certificate
Lloyds register Certificate, Contactor, AF400...AF2850
UL Certificate
cULus Certificate, Contactor, AF1250
Package Level 1 Units
box 1 piece
Package Level 1 Width
280 mm
Package Level 1 Depth / Length
375 mm
Package Level 1 Height
310 mm
Package Level 1 Gross Weight
16 kg
Package Level 1 EAN
7320500541715
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
Feature → Business Impact → Application: Three-pole design with 3 main NO contacts and 0 NC contacts ensures robust switching for high-current motor control, reducing wiring complexity and enabling compact panel layouts for critical machinery. This translates to improved system reliability and easier serviceability in manufacturing lines and renewable energy installations. Feature → Business Impact → Application: Wide control circuit voltage of 100-250 V AC/DC supports diverse control architectures, enabling seamless integration with existing PLCs and legacy equipment while reducing spare-part variety and stock costs for OEMs and integrators. Feature → Business Impact → Application: High short-time withstand current and maximum breaking capacity deliver rapid, secure interruption under fault or inrush conditions, minimizing downtime in pumps, conveyors, and fans in process industries. Feature → Business Impact → Application: Solid mechanical durability (0.5 million operations) and robust enclosure interfaces limit maintenance cycles and extend service life in harsh environments such as outdoor substations and solar/w wind farms. Feature → Business Impact → Application: Clear connection schemes (Bar 50 mm² main, flexible 2x0.75–2.5 mm² auxiliary) simplify installation and ensure reliable torqueing and torque specs, reducing commissioning time and operator error in control panels. Feature → Business Impact → Application: Comprehensive compliance footprint (CE, UL/CSA, UKCA) supports global deployment, reduces regulatory risk, and accelerates time-to-market for renewable energy projects and industrial automation retrofits.
Get a Quick Quote for a ABB 1SFL647033R7022
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SFL647033R7022?
Enquire Now
FAQs
Ensure main terminals accept Bar 50 mm² conductors and auxiliary terminals support 2x0.75–2.5 mm² ferrule or 2x 0.75–2.5 mm² flexible conductors. Plan panel space for 210 mm width, 242 mm depth, and 344 mm height, and verify enclosure IP ratings align with your environment. Torque requirements are 45 N·m for cable lugs; use the dimension diagram for precise mounting.
Rated operational current Ie varies by voltage and temperature: at 1140 V and 40 °C, Ie is 1260 A. At 55 °C it reduces to 1040 A, and at 70 °C to 875 A. For 690 V operation, Ie remains 1260 A at 40 °C, decreasing with temperature. This makes the device suitable for high-load motor and pump applications.
Yes. It supports up to 1140 V mains, 100-250 V control, and features a 3P main contactor with 3 NO main contacts plus 2 NO/2 NC auxiliaries, ideal for motor protection and control in wind and solar inverter interfaces. Its high Icw, substantial breaking capacity, and robust mechanical durability help handle inrush and fault conditions common in renewable systems.
The device carries CE and UL/CSA certifications, plus UKCA, and additional declarations such as EAC and RoHS where applicable. These certifications support global deployment, simplify regulatory approvals, and reduce risk when integrating into international automation projects.
Expect extended service intervals due to high mechanical durability (about 0.5 million operations) and robust terminal design, reducing replacement and maintenance costs. The wide coil voltage range simplifies stocking and reduces spare parts, while high current handling and fault tolerance improve uptime, delivering favorable total cost of ownership in continuous operation environments.