ABB AF1350-30-11 Contactor - 3P, 1000 V CE/UL certified

Part Number: 1SFL657033R7011
Manufacturer
ABB
Part number
1SFL657033R7011

Quick Summary

The ABB AF1350-30-11 Contactor is a 3-pole motor controller for industrial motor starts. Its wide control voltage range of 100-250 V AC/DC minimizes tripping and stabilizes panel energy in networks with voltage fluctuations. The device carries CE, UL/CSA, UKCA and EAC certifications, ensuring global compliance across diverse production sites. Built-in surge protection and AF technology deliver a compact, robust protection solution with easy expansion via auxiliary contact blocks. This combination supports reliable motor protection and control in machine-building environments, process lines, and packaging equipment, delivering reduced downtime and simplified commissioning for engineers and procurement teams.

Product Information

Extended Description

1SFL657033R7011 ABB: The AF1350-30-11-70 CT19001 is a 3 pole - 1000 V IEC or 1000 V UL contactor with pre-mounted auxiliary contacts and Main Circuit Bars, controlling motors up to 475 kW / 400 V AC (AC-3) and switching power circuits up to 1350 A (AC-1) or 1350 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (100-250 V 50/60 Hz and DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100214C0202 - Main catalog Motor protection and control Manual motor starters, contactors and overload relays (PDF) - Edition 2024
Data Sheet, Technical Information (Part 2)
Contactors and Overload relays guide
Instructions and Manuals
Operating instruction, Contactors AF1350, AF1650,AF2050
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Dimension Diagram
Dimension Drawing, Contactor, AF1350, AF1650
Product Net Width
438 mm
Product Net Depth / Length
244 mm
Product Net Height
392 mm
Product Net Weight
32 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
1
Number of Auxiliary Contacts NC
1
Number of Poles
3P
Rated Operational Voltage
Main Circuit 1140 V
Rated Frequency (f)
Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 1350 A
Rated Operational Current AC-1 (Ie)
(1000 V) 40 °C 1350 A | (1000 V) 55 °C 1150 A | (1000 V) 70 °C 1000 A | (690 V) 40 °C 1350 A | (690 V) 55 °C 1150 A | (690 V) 70 °C 1000 A | (1140 V) 40 °C 1350 A
Rated Operational Current AC-3 (Ie)
(1000 V) 55 °C 375 A | (220 / 230 / 240 V) 55 °C 860 A
Rated Operational Current DC-1 (Ie)
(220 V) 3 Poles in Series, 40 °C 1350 A | (600 V) 3 Poles in Series, 40 °C 1350 A | (850 V) 3 Poles in Series, 40 °C 1350 A
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 8000 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 1600 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 4500 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 10000 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 6000 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 10000 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1140 V | acc. to UL/CSA 1000 V
Rated Impulse Withstand Voltage (Uimp)
Main Circuit 8 kV
Maximum Electrical Switching Frequency
(AC-1) 60 cycles per hour
Mechanical Durability
0.5 million
Maximum Mechanical Switching Frequency
300 cycles per hour
Coil Operating Limits
(acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C)
Rated Control Circuit Voltage (Uc)
50 Hz 100 ... 250 V | 60 Hz 100 ... 250 V | DC Operation 100 ... 250 V
Coil Consumption
Holding at Max. Rated Control Circuit Voltage 50 Hz 48 V·A | Holding at Max. Rated Control Circuit Voltage 60 Hz 48 V·A | Holding at Max. Rated Control Circuit Voltage DC 20.5 V·A | Pull-in at Max. Rated Control Circuit Voltage 50 Hz 2450 V·A | Pull-in at Max. Rated Control Circuit Voltage 60 Hz 2450 V·A | Pull-in at Max. Rated Control Circuit Voltage DC 2290 V·A
Power Loss
at Rated Operating Conditions per Pole 80 W
Operate Time
Between Coil De-energization and NC Contact Closing 35 ... 55 ms | Between Coil De-energization and NO Contact Opening 35 ... 55 ms | Between Coil Energization and NC Contact Opening 50 ... 80 ms | Between Coil Energization and NO Contact Closing 50 ... 80 ms
Connecting Capacity Main Circuit
Bar 100 mm²
Connecting Capacity Auxiliary Circuit
Flexible with Ferrule 1x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² | Flexible 2x0.75 ... 2.5 mm² | Solid 2 x 1 ... 4 mm² | Stranded 1 x 1 .... 4 mm²
Connecting Capacity
Bar 100 mm²
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Tightening Torque
Cable Lug 45 N·m
Terminal Type
Main Circuit: Bars
Product Name
Block Contactor
Maximum Operating Voltage UL/CSA
Main Circuit 1000 V
General Use Rating UL/CSA
(1000 V AC) 1350 A | (600 V AC) 1350 A
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °C | Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C | Close to Contactor for Storage -40 ... 70 °C
Maximum Operating Altitude Permissible
Without Derating 3000 m
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
End Of Life Disassembling Instructions
End-of-life instruction - AF1350(B)(T), AF1650(B)(T), AF1650N8, AF2050(B)(T), AF2650(B)(T), AF2850(B)(T)
Environmental Product Declaration - EPD
Environmental product declaration AF1350, AF1650, AF2050, AF2650 (CN) Contactors
CB Certificate
SEMKO_SE-74013
CCS Certificate
CCS Certificate, Contactor, AF116 to AF2850 (Sweden)
CQC Certificate
CQC Certificate, AC Contactor, AF1350-30-*-*, AF1650-30-*-*, AF2050-30-*-*, AF1350T-30-*-*, AF1650T-30-*-*, AF2050T-30-*-*, Made in Sweden | CQC Certificate, Contactor, AF1350, AF1650, AF2050, Made in China
Declaration of Conformity - CCC
CCC Declaration of Conformity, AC Contactor, AF1350-30-*-*, AF1650-30-*-*, AF2050-30-*-*, AF1350T-30-*-*, AF1650T-30-*-*, AF2050T-30-*-*, Made in Sweden | CCC Declaration of Conformity, Contactor, AF1350, AF1650, AF2050, Made in China
Declaration of Conformity - CE
CE Declaration of Conformity - Contactor - AF400...AF2850
Declaration of Conformity - UKCA
UK Declaration of Conformity - Contactors >100A
EAC Certificate
9AKK107046A8618
LR Certificate
Lloyds register Certificate, Contactor, AF400...AF2850
UL Certificate
cULus Certificate, Contactor, AF1350, AF1650, AF2050 (NLDX)
Package Level 1 Units
box 1 piece
Package Level 1 Width
555 mm
Package Level 1 Depth / Length
365 mm
Package Level 1 Height
500 mm
Package Level 1 Gross Weight
34 kg
Package Level 1 EAN
7320500524947
Package Level 2 Units
1 piece
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
AF technology enables a wide control voltage range and integrated surge protection, reducing panel energy consumption and improving reliability in networks with voltage swings. This translates to lower operating costs and fewer interruptions during critical production runs, making it ideal for motor starters on conveyors and processing lines. The three-pole main contact set with pre-mounted auxiliary contacts (one NO and one NC) provides ready-to-wire functionality and simplifies panel layout while supporting scalable control through add-on auxiliary blocks for future expansion. The AF1350 design uses 100 mm² main circuit bars, delivering robust current handling for power circuits up to 1350 A (AC-1) and 375 A (AC-3) at 1000 V, enabling compact yet capable installations in high-power applications. With rated insulation of 1140 V and a 8 kV impulse withstand, this unit meets demanding safety standards and supports long service life in challenging environments. Its enclosure-friendly IP20 coil terminals and IP00 main terminals, combined with a 45 N·m tightening torque for cable lugs, simplify installation and maintenance while preserving connection integrity. The coil consumption figures—holding at 50 Hz 48 V·A and pull-in at 50 Hz 2450 V·A—coupled with a power loss of 80 W per pole, offer measurable energy savings and predictable thermal performance, reducing the need for oversized cooling in control panels. An additional advantage is the 0.5 million mechanical durability rating, delivering confidence in high-cycle applications and minimizing replacement costs over the equipment lifecycle.

Get a Quick Quote for a ABB 1SFL657033R7011

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SFL657033R7011? Enquire Now

FAQs

Install the AF1350-30-11 by mounting the unit in a suitable enclosure, connecting the main circuit bars with 100 mm² conductors, and wiring the auxiliary contact set (1 NO, 1 NC). Maintain the recommended cable lug torque of 45 N·m and ensure IP20 coil terminals and IP00 main terminals are properly sealed. The design supports add-on auxiliary blocks for future expansion, simplifying scalability during line upgrades.
Ie AC-1 indicates continuous operation with linear loads (motors in running condition) and allows up to 1350 A at 1000 V (40 °C). Ie AC-3 covers starting and switching of inductive loads (motors) with lower current, rated here at 375 A at 1000 V. These ratings guide motor sizing and ensure safe, reliable operation in typical industrial drives.
Yes, the AF1350-30-11 supports DC operation for the control circuit within the 100 to 250 V range. This flexibility helps maintain reliable coil energization in systems where DC control is preferred or where AC supply quality fluctuates, ensuring consistent actuation without frequent coil failures.
The device carries CE, UL/CSA, UKCA, and EAC certifications, among others, confirming compliance with major global standards for electrical equipment. These certifications simplify cross-border procurement, validate safety and reliability, and support regulatory acceptance for installations in diverse markets such as Europe, North America, and the UK.
Maintenance is minimized by robust mechanical durability (0.5 million cycles) and reliable surge protection, reducing replacement intervals. The coil consumption profile, combined with 80 W power loss per pole, supports energy efficiency in panel design. Overall, customers can expect lower downtime, fewer spare parts, and a shorter payback period in high-demand motor control applications.