ABB AF2650-30-22-70 Block Contactor - 1000 V UL/CE Certified

Part Number: 1SFL667001R7022
Manufacturer
ABB
Part number
1SFL667001R7022

Quick Summary

The ABB AF2650-30-22-70 is a high-capacity block contactor designed for heavy motor control in industrial automation. In practice, panel builders face voltage variations and control range gaps that disrupt reliable operation; this device delivers a wide control voltage range of 100–250 V AC/50/60 Hz and DC, reducing commissioning time and energy waste. It carries CE and UL/CSA conformity, with UKCA and CB/CQC certifications adding confidence for global deployments. Additionally, the product portfolio supports RoHS and REACH declarations, aligning with sustainable manufacturing standards. For customers, this means fewer parts, easier compliance, and a scalable solution that grows with evolving plant needs while maintaining safe, predictable switching performance.

Product Information

Extended Description

1SFL667001R7022 ABB: The AF2650-30-22-70 is a 3 pole - 1000 V IEC or 1000 V UL contactor with pre-mounted auxiliary contacts and Main Circuit Bars, switching power circuits up to 2650 A (AC-1) or 2700 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (100-250 V 50/60 Hz and DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100214C0202 - Main catalog Motor protection and control Manual motor starters, contactors and overload relays (PDF) - Edition 2024
Data Sheet, Technical Information (Part 2)
Contactors and Overload relays guide
Instructions and Manuals
Operating instruction, Contactors AF2650(T), AF2850(T)
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
438 mm
Product Net Depth / Length
244 mm
Product Net Height
422 mm
Product Net Weight
43 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
2
Number of Auxiliary Contacts NC
2
Number of Poles
3P
Rated Operational Voltage
Main Circuit 1000 V
Rated Frequency (f)
Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 2650 A
Rated Operational Current AC-1 (Ie)
(1000 V) 40 °C 2650 A | (1000 V) 55 °C 2350 A | (1000 V) 70 °C 2120 A | (690 V) 40 °C 2650 A | (690 V) 55 °C 2350 A | (690 V) 70 °C 2120 A
Rated Operational Current DC-1 (Ie)
(110 V) 1-Pole, 70 °C 2650 A | (110 V) 2 Poles in Series, 70 °C 2650 A | (110 V) 3 Poles in Series, 70 °C 2650 A | (220 V) 3 Poles in Series, 40 °C 2650 A | (220 V) 3 Poles in Series, 70 °C 2650 A | (260 V) 3 Poles in Series, 70 °C 2650 A | (300 V) 3 Poles in Series, 70 °C 2650 A | (340 V) 3 Poles in Series, 70 °C 2650 A | (600 V) 3 Poles in Series, 40 °C 2650 A | (72 V) 1-Pole, 70 °C 2650 A | (72 V) 2 Poles in Series, 70 °C 2650 A | (72 V) 3 Poles in Series, 70 °C 2650 A | (850 V) 3 Poles in Series, 40 °C 2650 A
Rated Making Capacity AC-3
10 x Ie AC-3
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 10000 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 2800 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 5500 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 12000 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 7500 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 8400 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V | acc. to UL/CSA 1000 V
Rated Impulse Withstand Voltage (Uimp)
Main Circuit 8 kV
Maximum Electrical Switching Frequency
(AC-1) 15 cycles per hour
Mechanical Durability
0.3 million
Maximum Mechanical Switching Frequency
300 cycles per hour
Coil Operating Limits
(acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C)
Rated Control Circuit Voltage (Uc)
50 Hz 100 ... 250 V | 60 Hz 100 ... 250 V | DC Operation 100 ... 250 V
Coil Consumption
Holding at Max. Rated Control Circuit Voltage 50 Hz 48 V·A | Holding at Max. Rated Control Circuit Voltage 60 Hz 48 V·A | Holding at Max. Rated Control Circuit Voltage DC 20.5 V·A | Pull-in at Max. Rated Control Circuit Voltage 50 Hz 2450 V·A | Pull-in at Max. Rated Control Circuit Voltage 60 Hz 2450 V·A | Pull-in at Max. Rated Control Circuit Voltage DC 2290 V·A
Power Loss
at Rated Operating Conditions per Pole 200 W
Operate Time
Between Coil De-energization and NC Contact Closing 35 ... 55 ms | Between Coil De-energization and NO Contact Opening 35 ... 55 ms | Between Coil Energization and NC Contact Opening 50 ... 80 ms | Between Coil Energization and NO Contact Closing 50 ... 80 ms
Connecting Capacity Main Circuit
Bar 100 mm²
Connecting Capacity Auxiliary Circuit
Flexible with Ferrule 1x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm² | Flexible 2x0.75 ... 2.5 mm² | Solid 2 x 1 ... 4 mm² | Stranded 2 x 1 .... 4 mm²
Connecting Capacity
Bar 100 mm²
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Tightening Torque
Cable Lug 45 N·m
Terminal Type
Main Circuit: Bars
Product Name
Block Contactor
Maximum Operating Voltage UL/CSA
Main Circuit 1000 V
General Use Rating UL/CSA
(1000 V AC) 2700 A | (600 V AC) 2700 A
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °C | Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C | Close to Contactor for Storage -40 ... 70 °C
Maximum Operating Altitude Permissible
Without Derating 3000 m
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
End Of Life Disassembling Instructions
End-of-life instruction - AF1350(B)(T), AF1650(B)(T), AF1650N8, AF2050(B)(T), AF2650(B)(T), AF2850(B)(T)
Environmental Product Declaration - EPD
Environmental product declaration AF1350(T), AF1650(T)(N), AF2050(T), AF2650(T), AF2850 (SE) | Environmental product declaration AF1350, AF1650, AF2050, AF2650 (CN) Contactors
CB Certificate
SEMKO_SE70500M1
CCS Certificate
CCS Certificate, Contactor, AF116 to AF2850 (Sweden)
CQC Certificate
CQC Certificate, AC Contactor, AF2650-30-*-*, AF2650T-30-*-*, AF2850-30-*-*, AF2850T-30-*-*, Made in Sweden | CQC Certificate, Contactor, AF2650, Made in China
Declaration of Conformity - CCC
CCC Declaration of Conformity, AC Contactor, AF2650-30-*-*, AF2650T-30-*-*, AF2850-30-*-*, AF2850T-30-*-*, Made in Sweden | CCC Declaration of Conformity, Contactor, AF2650, Made in China
Declaration of Conformity - CE
CE Declaration of Conformity - Contactor - AF400...AF2850
Declaration of Conformity - UKCA
UK Declaration of Conformity - Contactors >100A
EAC Certificate
9AKK107046A8618
LR Certificate
Lloyds register Certificate, Contactor, AF400...AF2850
RINA Certificate
RINA Certificate, AF95, AF110, AF145, AF185, AF210, AF260, AF300, AF400, AF460, AF580, AF750, AF1250, AF1350, AF1650, AF2050, AF2650, AF116, AF140, AF146, AF190, AF205, AF265, AF305, AF370
RMRS Certificate
9AKK107045A6978
UL Certificate
cULus Certificate, Contactor, AF2650...AF2850
UL Listing Card
UL_E73397
Package Level 1 Units
box 1 piece
Package Level 1 Width
555 mm
Package Level 1 Depth / Length
365 mm
Package Level 1 Height
500 mm
Package Level 1 Gross Weight
45 kg
Package Level 1 EAN
7320500481660
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4758 >> Iec Contactors
E-Number (Finland)
3706013
AF2650-30-22-70 leverages AF technology to manage large power circuits with a 3-pole main contactor architecture, enabling reliable start-stop sequences in demanding environments. This translates to a measurable business impact: higher uptime and reduced maintenance costs when running high-power motors like conveyors, pumps, and presses. The wide control voltage range and DC operation minimize panel wiring variations and energy waste, simplifying commissioning and improving control reliability across mixed power networks. The device includes pre-mounted auxiliary contacts and main circuit bars, so expansion with add-on blocks is straightforward, supporting scalable control logic without replacing the base unit. Built-in surge protection adds resilience against voltage transients seen in industrial plants, reducing nuisance trips and extending service life. The compact block design streamlines enclosure layout, while the 100 mm² main circuit connection and 100 mm² auxiliary capacity support straightforward wiring and robust torque performance. With 3P configuration and solid insulation, installation is compatible with standard ABB motor protection and control ecosystems, easing spare-part planning and maintenance. Coil consumption data—holding and pull-in values at 50/60 Hz and DC—helps engineers model energy use and thermal behavior, supporting better panel cooling design and energy audits. Operating temperatures from -25 to +70 °C (with and without thermal overload) and up to 3,000 m altitude without derating provide reliability in diverse sites. Finally, the device’s durable mechanical design promises up to 0.3 million cycles, delivering long-term throughput in high-demand automation lines.

Get a Quick Quote for a ABB 1SFL667001R7022

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SFL667001R7022? Enquire Now

FAQs

The AF2650-30-22-70 is designed to integrate with ABB motor protection and control assemblies. It uses standard 3P main circuits with 100 mm² bars and supports add-on auxiliary contact blocks, enabling seamless expansion in existing cabinets. When matching, ensure your panel supports 1000 V insulation, 3P configuration, and the 100-250 V control range to minimize rewiring and optimize space usage.
For AC-1, the AF2650-30-22-70 handles up to 2650 A at 1000 V (with variations by ambient temperature). DC-1 ratings are specified across multiple voltages with 2650 A capability for 110–600 V ranges. It also offers a rated short-time withstand current (Icw) up to 12000 A for short pulses and a maximum breaking capacity of 8400 A at high voltages, ensuring reliable switching of large motors.
Yes. With a 3-pole main circuit rated up to 2650 A AC-1, 1000 V insulation, and built-in surge protection, the AF2650-30-22-70 is engineered for heavy-load motor control in conveyors, pumps, and presses. Its wide operating temperature range, IP20 coil terminals, and IP00 main terminals support robust operation in plant floors and control panels alike.
This ABB contactor comes with CE and UL/CSA conformity, UKCA marking, and a broad certificate portfolio (CB, CQC, CCC, RINA, UL listings) that supports global deployments. REACH and RoHS declarations are included, helping meet environmental and material safety requirements for automotive, energy, and industrial equipment supply chains.
The device combines high current capability with a durable mechanical design (approximately 0.3 million cycles) and low coil energy usage, which reduces energy consumption and cooling needs in the control panel. Its modularity—auxiliary blocks and add-on options—minimizes downtime for expansion, delivering a shorter maintenance window and lower total cost of ownership over the system life.