ABB AF1650-30-11 Contactor - CE & UL Certified, 1000 V
Part Number: 1SFL677001R7011
Quick Summary
ABB AF1650-30-11 Contactor is a three-pole motor starter for industrial panel control. In demanding environments, voltage variation can cause nuisance trips and downtime, jeopardizing production schedules. This AF family device carries CE conformity, UL/CSA recognition, and RoHS/REACH compliance to support global deployments. The compact block design, pre-mounted auxiliary contact, and the ability to extend with add-on contact blocks simplify panel wiring and future upgrades. Its wide control voltage range (100-250 V AC, 50/60 Hz, and DC operation) reduces panel energy consumption and improves reliability in unstable networks. By combining robust protection with easy installation, it delivers tangible efficiency, uptime, and lifecycle cost benefits for OEMs and end users.
Product Information
Extended Description
1SFL677001R7011 ABB: The AF1650-30-11-70 is a 3 pole - 1000 V IEC or 1000 V UL contactor pre-mounted auxiliary contacts and and Main Circuit Bars, controlling motors up to 560 kW / 400 V AC (AC-3) or 900 hp / 480 V UL and switching power circuits up to 1650 A (AC-1) or 1650 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (100-250 V 50/60 Hz and DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.
Lead Time
28 day
Made To Order
No
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
USSVCEXPU
Warranty Return
Product under warranty must be returned
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100214C0202 - Main catalog Motor protection and control Manual motor starters, contactors and overload relays (PDF) - Edition 2024
Data Sheet, Technical Information (Part 2)
Contactors and Overload relays guide
Instructions and Manuals
Operating instruction, Contactors AF1350, AF1650,AF2050
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Dimension Diagram
Dimension Drawing, Contactor, AF1350, AF1650
Product Net Width
438 mm
Product Net Depth / Length
244 mm
Product Net Height
392 mm
Product Net Weight
33 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
1
Number of Auxiliary Contacts NC
1
Number of Poles
3P
Rated Operational Voltage
Main Circuit 1000 V
Rated Frequency (f)
Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 1650 A
Rated Operational Current AC-1 (Ie)
(1000 V) 40 °C 1650 A | (1000 V) 55 °C 1450 A | (1000 V) 70 °C 1270 A | (690 V) 40 °C 1650 A | (690 V) 55 °C 1450 A | (690 V) 70 °C 1270 A
Rated Operational Current AC-3 (Ie)
(1000 V) 55 °C 400 A | (220 / 230 / 240 V) 55 °C 1060 A
Rated Operational Current DC-1 (Ie)
(110 V) 1-Pole, 40 °C 1650 A | (110 V) 2 Poles in Series, 40 °C 1650 A | (220 V) 3 Poles in Series, 40 °C 1650 A | (600 V) 3 Poles in Series, 40 °C 1650 A | (850 V) 3 Poles in Series, 40 °C 1650 A
Rated Operational Power AC-3 (Pe)
(415 V) 630 kW | (440 V) 710 kW | (500 V) 710 kW | (690 V) 1000 kW | (1000 V) 600 kW | (380 / 400 V) 560 kW | (220 / 230 / 240 V) 315 kW
Rated Making Capacity AC-3
10 x Ie AC-3
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 10000 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 2200 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 5500 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 12000 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 7500 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 12000 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V | acc. to UL/CSA 1000 V
Rated Impulse Withstand Voltage (Uimp)
Main Circuit 8 kV
Maximum Electrical Switching Frequency
(AC-1) 60 cycles per hour | (AC-2 / AC-4) 60 cycles per hour | (AC-3) 60 cycles per hour
Mechanical Durability
0.5 million
Maximum Mechanical Switching Frequency
300 cycles per hour
Coil Operating Limits
(acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C)
Rated Control Circuit Voltage (Uc)
50 Hz 100 ... 250 V | 60 Hz 100 ... 250 V | DC Operation 100 ... 250 V
Coil Consumption
Holding at Max. Rated Control Circuit Voltage 50 Hz 48 V·A | Holding at Max. Rated Control Circuit Voltage 60 Hz 48 V·A | Holding at Max. Rated Control Circuit Voltage DC 20.5 V·A | Pull-in at Max. Rated Control Circuit Voltage 50 Hz 2450 V·A | Pull-in at Max. Rated Control Circuit Voltage 60 Hz 2450 V·A | Pull-in at Max. Rated Control Circuit Voltage DC 2290 V·A
Power Loss
at Rated Operating Conditions per Pole 80 W
Operate Time
Between Coil De-energization and NC Contact Closing 35 ... 55 ms | Between Coil De-energization and NO Contact Opening 35 ... 55 ms | Between Coil Energization and NC Contact Opening 50 ... 80 ms | Between Coil Energization and NO Contact Closing 50 ... 80 ms
Connecting Capacity Main Circuit
Bar 100 mm²
Connecting Capacity Auxiliary Circuit
Flexible with Ferrule 2x 0.75 ... 2.5 mm² | Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² | Flexible 2x0.75 ... 2.5 mm² | Solid 2 x 1 ... 4 mm² | Stranded 2 x 1 .... 4 mm²
Connecting Capacity
Bar 100 mm²
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 | acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Tightening Torque
Cable Lug 45 N·m
Terminal Type
Main Circuit: Bars
Product Name
Block Contactor
NEMA Size
8
Horsepower Rating NEMA
(230 V AC) Three Phase 450 Hp | (460 V AC) Three Phase 900 Hp | (575 V AC) Three Phase 900 Hp
Maximum Operating Voltage UL/CSA
Main Circuit 1000 V
General Use Rating UL/CSA
(1000 V AC) 1650 A | (600 V AC) 1650 A
Horsepower Rating UL/CSA
(220 ... 240 V AC) Three Phase 450 hp | (440 ... 480 V AC) Three Phase 900 hp | (550 ... 600 V AC) Three Phase 1150 hp
Full Load Amps Motor Use
(440 ... 480 V AC) Three Phase 1030 A | (550 ... 600 V AC) Three Phase 1050 A
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °C | Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C | Close to Contactor for Storage -40 ... 70 °C
Maximum Operating Altitude Permissible
Without Derating 3000 m
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
End Of Life Disassembling Instructions
End-of-life instruction - AF1350(B)(T), AF1650(B)(T), AF1650N8, AF2050(B)(T), AF2650(B)(T), AF2850(B)(T)
Environmental Product Declaration - EPD
Environmental product declaration AF1350(T), AF1650(T)(N), AF2050(T), AF2650(T), AF2850 (SE) | Environmental product declaration AF1350, AF1650, AF2050, AF2650 (CN) Contactors
ABS Certificate
ABS Certificate, Contactor, AF400...AF2050 (Sweden)
BV Certificate
BV Certificate, Contactor, AF400 ... AF2850
CB Certificate
SEMKO_SE-74013
CCS Certificate
CCS Certificate, Contactor, AF116 to AF2850 (Sweden)
CQC Certificate
CQC Certificate, AC Contactor, AF1350-30-*-*, AF1650-30-*-*, AF2050-30-*-*, AF1350T-30-*-*, AF1650T-30-*-*, AF2050T-30-*-*, Made in Sweden | CQC Certificate, Contactor, AF1350, AF1650, AF2050, Made in China
Declaration of Conformity - CCC
CCC Declaration of Conformity, AC Contactor, AF1350-30-*-*, AF1650-30-*-*, AF2050-30-*-*, AF1350T-30-*-*, AF1650T-30-*-*, AF2050T-30-*-*, Made in Sweden | CCC Declaration of Conformity, Contactor, AF1350, AF1650, AF2050, Made in China
Declaration of Conformity - CE
CE Declaration of Conformity - Contactor - AF400...AF2850
Declaration of Conformity - UKCA
UK Declaration of Conformity - Contactors >100A
DNV GL Certificate
DNV Certificate, Contactor, AF400...AF2850
EAC Certificate
9AKK107046A8618
GL Certificate
GL_20263-04HH
LOVAG Certificate
SE-201993
LR Certificate
Lloyds register Certificate, Contactor, AF400...AF2850
PRS Certificate
PRS Certificate - AF116...AF1650
RINA Certificate
RINA Certificate, AF95, AF110, AF145, AF185, AF210, AF260, AF300, AF400, AF460, AF580, AF750, AF1250, AF1350, AF1650, AF2050, AF2650, AF116, AF140, AF146, AF190, AF205, AF265, AF305, AF370
RMRS Certificate
9AKK107045A6978
UL Certificate
cULus Certificate, Contactor, AF1350, AF1650, AF2050 (NLDX)
UL Listing Card
UL_E73397
Package Level 1 Units
box 1 piece
Package Level 1 Width
555 mm
Package Level 1 Depth / Length
365 mm
Package Level 1 Height
500 mm
Package Level 1 Gross Weight
35 kg
Package Level 1 EAN
7320500249703
Package Level 2 Units
1 piece
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4758 >> Iec Contactors
E-Number (Finland)
3709258
E-Number (Norway)
4115390
E-Number (Sweden)
4115390
Feature: Three-pole block contactor with 3 main contacts and 1 NO plus 1 NC auxiliary contact. Benefit: Supports high current motor loads up to 1650 A and simplifies wiring with integrated auxiliary contacts, enabling immediate panel deployment for pumps, conveyors, or machine tools. Application: Ideal for OEM equipment and retrofit projects that demand reliable switching of large motors. Feature: Wide control voltage tolerance and versatile coil operation (50 Hz 100-250 V, 60 Hz 100-250 V, DC 100-250 V). Benefit: Reduces wiring diversity and accommodates voltage fluctuations in unstable networks, cutting panel energy waste and downtime. Application: Suitable for systems with varied supply conditions or remote installations. Feature: AF technology with built-in surge protection and a compact block design. Benefit: Delivers high reliability in short-circuit and transient-rich environments, while saving panel space and enabling scalable control with add-on contact blocks. Application: OEM controls for packaging lines and processing machines. Feature: Robust electrical ratings (Main Circuit up to 1000 V, AC-3 current up to 1650 A, and DC-1 up to 1650 A). Benefit: Supports heavy-duty motor starting and line switching across multi-voltage installations, reducing need for multiple devices. Application: Large drive applications and heavy machinery. Feature: Expandability and compatibility (pre-mounted auxiliary contacts, add-on blocks). Benefit: Simplifies future upgrades and maintenance planning, reducing downtime during changes. Application: Modular automation scenarios and end-of-line equipment builds.
Get a Quick Quote for a ABB 1SFL677001R7011
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SFL677001R7011?
Enquire Now
FAQs
The AF1650-30-11 is a three-pole motor starter intended for industrial panel control in applications such as pumps, conveyors, and machine tools. It handles high-current loads up to 1650 A, with a main circuit rated to 1000 V and built-in auxiliary contacts for streamlined wiring and control circuit integration.
The contactor supports a wide control voltage range: 50 Hz 100-250 V, 60 Hz 100-250 V, and DC 100-250 V. Coil consumption is 48 VA holding at max rated voltage (50/60 Hz) and 20.5 VA for DC hold, with higher pull-in requirements of 2450 VA (50/60 Hz) or 2290 VA (DC).
It provides AC-3 rated operation up to 400 A at 1000 V and up to 1060 A at 690 V, with a high breaking capacity and fast operate times. The device is designed for motor protection and control in demanding loads, including surge protection and the ability to add auxiliary contacts for comprehensive interlocking and signaling.
The AF1650 series carries CE conformity and UL/CSA certification, with UKCA declarations and RoHS/REACH compliance. It is also supported by multiple certificates and declarations such as UL Certificate, UL Listing Card, and RoHS/REACH documentation to aid global compliance.
With a 0.5 million mechanical operations rating and a robust 3P design, the AF1650-30-11 delivers long service life under heavy duty. Built-in surge protection, compact wiring, and easy expansion reduce maintenance time, while energy-efficient coil consumption lowers operating costs—translating to lower lifecycle costs and quicker ROI in high-load automation environments.