ABB 1SFL991074R8011 Block Contactor AX150-30-11-80 - UL/CE
Part Number: 1SFL991074R8011
Quick Summary
ABB 1SFL991074R8011 is a high-capacity three-pole block contactor designed for reliable motor control in demanding industrial applications. Engineers often struggle with mis-sizing, inrush, and downtime caused by undersized devices in production lines. This model carries CE and UL certifications, IEC 60947-4-1 conformity, and RoHS compliance to support global installations and durable service. By aligning with ABB's motor protection ecosystem, users gain straightforward commissioning, consistent performance in harsh environments, and reduced maintenance cycles. The device's robust construction, compact footprint, and compatibility with standard CAD drawings accelerate installation and ongoing spare-part management, delivering faster project timelines and lower total cost of ownership.
Product Information
Extended Description
1SFL991074R8011 ABB: AX150-30-11-80 Contactor
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
1SBC100214C0202 - Main catalog Motor protection and control Manual motor starters, contactors and overload relays (PDF) - Edition 2024
Instructions and Manuals
AX 90~150A instructions
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
102 mm
Product Net Depth / Length
123.5 mm
Product Net Height
148 mm
Product Net Weight
1.9 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
1
Number of Auxiliary Contacts NC
1
Number of Poles
3P
Rated Operational Voltage
Main Circuit 1000 V
Rated Frequency (f)
Main Circuit 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 190 A
Rated Operational Current AC-1 (Ie)
(690 V) 40 °C 190 A | (690 V) 55 °C 145 A | (690 V) 70 °C 130 A
Rated Operational Current AC-3 (Ie)
(415 V) 55 °C 150 A | (440 V) 55 °C 100 A | (500 V) 55 °C 100 A | (690 V) 55 °C 82 A | (380 / 400 V) 55 °C 150 A | (220 / 230 / 240 V) 55 °C 150 A
Rated Operational Power AC-3 (Pe)
(415 V) 75 kW | (440 V) 59 kW | (500 V) 59 kW | (690 V) 75 kW | (380 / 400 V) 75 kW | (220 / 230 / 240 V) 45 kW
Rated Breaking Capacity AC-3
8 x Ie AC-3
Rated Making Capacity AC-3
10 x Ie AC-3
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 800 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 160 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 350 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1320 A | at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 500 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
Rated Impulse Withstand Voltage (Uimp)
8 kV
Maximum Electrical Switching Frequency
300 cycles per hour
Mechanical Durability
10 million
Maximum Mechanical Switching Frequency
3600 cycles per hour
Coil Operating Limits
(acc. to IEC 60947-4-1) Uc (at θ ≤ 70 °C)
Rated Control Circuit Voltage (Uc)
50 Hz 220 ... 230 V | 60 Hz 230 ... 240 V
Power Loss
at Rated Operating Conditions per Pole 2.7 W
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP40
Terminal Type
Main Circuit: Bars
Product Name
Block Contactor
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 55 °C | Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C | Close to Contactor for Storage -40 ... 70 °C
Maximum Operating Altitude Permissible
Without Derating 3000 m
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Information
RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessories
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Contactors
WEEE B2C / B2B
Business To Business
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
CQC Certificate
CQC Certificate, Contactor, AX95, AX115, AX150, Made in China
Declaration of Conformity - CCC
CCC Declaration of Conformity, Contactor, AX95, AX115, AX150, Made in China
Declaration of Conformity - CE
CE Declaration of conformity - Contactor - AX95...AX370
UL Certificate
cULus Certificate, Contactor, A95...A110, AX95...AX150
Package Level 1 Units
box 1 piece
Package Level 1 Width
140 mm
Package Level 1 Depth / Length
170 mm
Package Level 1 Height
130 mm
Package Level 1 Gross Weight
2.1 kg
Package Level 1 EAN
7320500500187
Object Classification Code
Q
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
ETIM 9
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4755 >> Contactors
Feature → Business Impact → Application: 3Pole design with 3 NO main contacts and 1 NO + 1 NC auxiliary contact ensures reliable motor control and expanded control signaling in a single device, reducing wiring complexity and panel size while improving control reliability for conveyors and pumps. Application: ideal for machine tools, material handling, and process lines where space is at a premium and dependability is critical. Feature → Business Impact → Application: Rated Operational Current AC-3 up to 150 A across multiple voltages (415 V to 690 V) delivers robust switching for high-inertia loads, enabling faster start-ups and reduced contact wear in fans, pumps, and compressors. Application: suitable for mid to large motors in manufacturing and packaging lines with demanding duty cycles. Feature → Business Impact → Application: Control circuit voltage options (50 Hz 220–230 V; 60 Hz 230–240 V) simplify integration with local control cabinets and PLCs, lowering wiring errors and commissioning time. Application: seamless integration in global plants with varying electrical standards. Feature → Business Impact → Application: Mechanical durability and electrical ratings (IEC 60947-4-1, 8 × Ie AC-3 breaking capacity, 2.7 W per pole power loss) translate to longer service life and predictable maintenance schedules. Application: essential for uptime in critical processes. Feature → Business Impact → Application: Compact footprint (102 mm width, 123.5 mm depth, 148 mm height) and 1.9 kg weight enable easier enclosure design, safer handling during installation, and reduced shipping costs across regional sites. Application: ideal for retrofits and new line builds where panel real estate is limited. Feature → Business Impact → Application: IP40 auxiliary terminals and wide operating temperature (-40 to 70 °C, up to 3000 m altitude without derating) provide resilience in demanding industrial environments. Application: recommended for harsh factory floors, outdoors enclosures, and high-altitude installations.
Get a Quick Quote for a ABB 1SFL991074R8011
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SFL991074R8011?
Enquire Now
FAQs
The device features a main circuit rated for up to 690 V insulation with rated control circuit voltages of 220–230 V at 50 Hz and 230–240 V at 60 Hz. It supports AC-3 duty with Ie up to 150 A depending on voltage, and offers 8 x Ie rated breaking capacity for safe switching of motor loads.
Yes. It is designed for AC-3 duty with current ratings ranging from 82 A to 150 A across different voltages, enabling reliable starting and running of motors with appreciable inrush and load inertia.
Product Net Width is 102 mm, Net Depth 123.5 mm, Net Height 148 mm, and Net Weight 1.9 kg, with a compact 3P form factor suitable for standard panel installations.
The product is UL certified and CE declared, with RoHS and REACH compliance. It is also supported by CCC/CQC declarations for broader regional acceptance and regulatory alignment.
Use main circuit bars for the terminals, ensure IP40 protection on auxiliary terminations, and plan for an operating range from -40 to 70 °C (up to 3000 m altitude without derating). CAD drawings are available to aid quick and accurate panel integration.