ABB 1SVR450116R5400 current transformer is a plug‑in device that converts 200 A primary current to a 5 A secondary signal for precise measurement in control panels and switchgear. Engineers often face installation complexity and space constraints when retrofitting metering or protection relays; this current transformer simplifies mounting with foot angle, insulating protective cap, and bar fastening screws, and offers an optional DIN rail snap‑on. It meets IEC/EN 61869‑1 and 61869‑2 standards and is declared CE and UKCA compliant, with RoHS/REACH adherence for electronics. The Class 1 accuracy and 5 VA burden support dependable monitoring and protective relays, while compact dimensions suit crowded enclosures. Documented data sheets and CAD files enable faster procurement and consistent performance for energy management and safety compliance.

Product Information

Extended Description

1SVR450116R5400 ABB: The CM-CT 200/5 is a plug-in current transformer from the CM-CT range. The current transformer has a rated primary current of 200 A and a secondary rated current of 5 A. The burden of the current transformer is 5 VA and its precision is according to class 1. The CM-CT 200/5 will be delivered with foot angle, insulating protective cap and bar fastening screws. A snap-on mounting for DIN rail is avaiable as accessory.
EAN
4013614376870
Minimum Order Quantity
1 piece
Customs Tariff Number
85043129
Data Sheet, Technical Information
Catalog 2024 Electronic Relays and Controls - Chapter Measuring and Monitoring Relays
Instructions and Manuals
Instructions - CM-CT Current transformers
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
61 mm
Product Net Height
78.5 mm
Product Net Depth / Length
48 mm
Product Net Weight
0.29 kg
Function
Current transformer
Standards
IEC/EN 63000 | IEC/EN 61869-1 | IEC/EN 61869-2
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACh Info for Electronic Relays and Controls
RoHS Information
RoHS Declaration of conformity for Electronic Relays and Controls
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA
REACh Info for Electronic Relays and Controls
Declaration of Conformity - CE
EU Declaration of Conformity - CM-CT Current transformers
Declaration of Conformity - UKCA
UK Declaration of Conformity - CM-CT Current transformers
Package Level 1 Units
box 1 piece
Package Level 1 Width
62 mm
Package Level 1 Depth / Length
90 mm
Package Level 1 Height
52 mm
Package Level 1 Gross Weight
0.295 kg
Package Level 1 EAN
4013614376870
Object Classification Code
T
ETIM 7
EC002048 - Current transformer
ETIM 8
EC002048 - Current transformer
ETIM 9
EC002048 - Current transformer
eClass
V11.0 : 27210902
UNSPSC
39121032
E-Number (Norway)
4187323
Feature → Business Impact → Application: Primary/current ratings of 200 A to 5 A secondary with Class 1 accuracy deliver trustworthy measurement inputs for protection relays and energy meters, reducing misoperation and improving system reliability. This translates to measurable improvements in uptime and safety in distribution boards and motor control centers. Application: ideal for panel boards, switchgear, and energy monitoring systems needing precise CT signals. Feature → Business Impact → Application: 5 VA burden minimizes additional loading on measurement circuits, lowering heat and supporting accurate readings even in high‑load environments. Application: suitable for metering relays and protection schemes in compact enclosures. Feature → Business Impact → Application: Plug‑in design with foot angle, insulating protective cap, and bar fastening screws accelerates installation and enhances safety, decreasing commissioning time and field errors. Application: straightforward retrofit in existing cabinets with optional DIN rail snap‑on mounting. Feature → Business Impact → Application: IEC/EN 61869‑1/2 compliance plus CE and UKCA declarations ensure regulatory readiness across regions, simplifying cross‑border deployments. Application: preferred choice for global projects requiring formal conformity. Feature → Business Impact → Application: Compact dimensions (61 mm width, 78.5 mm height, 48 mm depth) and lightweight (0.29 kg) enable efficient space planning and easier wiring in dense panels. Application: installation in tight electrical enclosures with reduced footprint. Feature → Business Impact → Application: Access to official data sheets, CAD drawings, and manuals streamlines engineering workflows and BOM accuracy. Application: procurement, design validation, and maintenance planning for reliability‑driven facilities.

Get a Quick Quote for a ABB 1SVR450116R5400

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SVR450116R5400? Enquire Now

FAQs

The CM-CT 200/5 is designed for straightforward plug-in installation. It ships with a foot angle and insulating protective cap, along with bar fastening screws. An optional snap-on DIN rail mounting accessory speeds installation in crowded panels, reduces wiring complexity, and ensures secure, vibration‑resistant operation in switchgear and meter cabinets.
Primary current rating is 200 A with a secondary rating of 5 A. The burden is 5 VA, and the device provides Class 1 accuracy. Standards compliance includes IEC/EN 61869‑1 and 61869‑2, and it carries CE and UKCA declarations along with RoHS/REACH conformity for electronics.
Yes. With a 200 A primary and 5 A secondary, plus a 5 VA burden and Class 1 accuracy, it delivers reliable sensor signals for metering relays and protection schemes. Its compact form factor and DIN rail compatibility simplify integration in distribution panels and motor control centers.
The device offers CE and UKCA declarations of conformity, along with RoHS and REACH compliance. It also adheres to IEC/EN 61869‑1/2 standards, supporting compliant use in European and UK markets for metering, protection, and energy management applications.
The transformer provides durable, low‑maintenance operation with robust mechanical design and standardized documentation. Its accurate measurements reduce nuisance trips and energy losses, improving system reliability and ROI. Easy installation minimizes commissioning costs, while long‑term support and readily available spare parts help sustain value over the asset life.