ABB 1SVR550855R9500 Liquid Level Relay - UL 508 Certified

Part Number: 1SVR550855R9500
Manufacturer
ABB
Part number
1SVR550855R9500

Quick Summary

Liquid level relay CM-ENE MIN protects pumps from dry running in industrial pumping applications. It addresses costly downtime and equipment wear by reliably detecting insufficient liquid levels before damage occurs. This device carries UL 508 and CE certifications, along with UKCA compliance, ensuring safe operation in North American and UK/EU environments. Built for DIN rail mounting with screw terminals, it integrates easily into existing control panels, minimizing wiring effort. In addition, its 24 V AC control supply and fixed 0-100 kΩ sensitivity provide consistent performance with common level sensors, supporting efficient maintenance routines and scalable, cost-effective pump protection across multiple systems.

Product Information

Extended Description

1SVR550855R9500 ABB: The CM-ENE MIN belongs to the CM liquid level monitoring relay range. It operates with a rated control supply voltage of 24 V AC and has a 1 n/o output contact. It protects pumps against dry running. The output relay works according to the open-circuit principle. The sensitivity is 0-100 kOhm fixed. The device offers screw connection terminals.
EAN
4013614349928
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Data Sheet, Technical Information
Catalog 2024 Electronic Relays and Controls - Chapter Measuring and Monitoring Relays
Instructions and Manuals
Installation instructions - CM-xxE range
CAD Dimensional Drawing
Information - 2D and 3D files for CAD systems
Product Net Width
22.5 mm
Product Net Height
78 mm
Product Net Depth / Length
78.5 mm
Product Net Weight
0.106 kg
Function
Draining monitoring
Sub-Function
Dry running protection
Number of Electrodes
2
Measuring Range
0 ... 100 kΩ
Rated Control Supply Voltage (Us)
24 V AC
Rated Frequency (f)
Supply Circuit 50/60 Hz
Output
1 n/o contact
Terminal Type
Screw Terminals
Rated Operational Current AC-12 (Ie)
(230 V) 4 A
Rated Operational Current AC-15 (Ie)
(230 V) 3 A
Rated Operational Current DC-12 (Ie)
(24 V) 4 A
Rated Operational Current DC-13 (Ie)
(24 V) 2 A
Rated Impulse Withstand Voltage (Uimp)
Measuring Circuit / Output Circuit 4 kV | Supply Circuit / Measuring Circuit 4 kV | Supply Circuit / Output Circuit 4 kV
Rated Insulation Voltage (Ui)
Measuring Circuit / Output Circuit 250 V | Supply Circuit / Measuring Circuit 250 V | Supply Circuit / Output Circuit 250 V
Degree of Protection
Housing IP50 | Terminals IP20
Short-Circuit Protective Devices
Output Circuit NO - F Type Fuses 10 A
Connecting Capacity
Flexible with Ferrule 2x 0.75 ... 1.5 mm² | Flexible 2x 1 ... 1.5 mm² | Rigid 2x 0.75 ... 1.5 mm²
Tightening Torque
0.6 ... 0.8 N·m
Wire Stripping Length
10 mm
Mounting Position
1 ... 6
Mounting on DIN Rail
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 | TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Standards
CAN/CSA C22.2 No.14 | IEC/EN 63000 | IEC/EN 61000-6-2 | IEC/EN 61000-6-3 | UL 508
Maximum Operating Voltage UL/CSA
Output Circuit 300 V AC
Contact Rating UL/CSA
B300
Connecting Capacity UL/CSA
Flexible with Ferrule 2x 18-16 AWG | Flexible 2x 18-16 AWG | Rigid 2x 18-16 AWG
Tightening Torque UL/CSA
7.08 in·lb
Ambient Air Temperature
Operation -20 ... +60 °C | Storage -40 ... +85 °C
Maximum Operating Altitude Permissible
Without Derating 2000 m
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
REACH Declaration
REACh Info for Electronic Relays and Controls
RoHS Information
RoHS Declaration of conformity for Electronic Relays and Controls
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
SCIP
7e2afe37-40b2-46f9-933b-88d78bd639a9 Germany (DE)
Simplified SCIP
0f865f55-7192-4d3d-b3a3-9def89e56fe1 Bulgaria (BG) | 1fa6fca1-8ba6-4e49-9b38-259c4abd6fad Spain (ES) | 1a9a3314-6437-40bd-9e2a-6dfb6f91a094 Germany (DE) | 42b6eced-b59e-4745-a37d-076ab620ed64 Finland (FI) | f1c8ca6a-103d-4556-a6c7-886dbdea074f Poland (PL) | 499aa4ba-0edc-436e-acf5-618e3f461656 Czech Republic (CZ) | 85cb361a-ec62-4f80-b6d1-4d9441cbd8a9 Poland (PL) | 4d6eaec0-e8a9-4a7d-8314-3ec378aa4f9e Denmark (DK) | 523de355-3d77-4193-8721-5b51afd91c3d Germany (DE) | 0d4bcb2a-d3ce-4bec-a1e2-62af8e0e2ce4 Estonia (EE) | ee5e01eb-65c0-4ab1-b954-deb8a94173a0 Italy (IT) | 30bbcd09-1d49-4521-9421-36f396002ad0 Germany (DE) | 2f1b7fe7-5522-4f5a-8f85-34c31217ca6e Netherlands (NL) | 12a13c37-b099-4210-824b-3206184c5857 Norway (NO) | f6759eb0-dd33-4a24-ab4e-fa439d640d1e Greece (GR) | d5a2adce-c123-4f72-a3a6-6e7e3f49d4d6 Croatia (HR) | 73b31fe8-fec8-4f9a-940b-561ceaaa1a45 Sweden (SE) | 66ee5090-8334-4958-9a42-6ac1d2de7519 France (FR) | 1b898c44-327d-4d7e-bcae-85690934a2ca Portugal (PT) | 306c2a13-e0be-4098-9c6a-1b0f80a4fa2b Hungary (HU) | 921fd37a-5684-4e52-b1f7-0db9c639d5b4 Belgium (BE) | c0b4d70a-6f6d-4fb7-a597-f5a61f38e917 France (FR) | e5e01b7b-0b6e-419e-a7c0-ebeaa66b413a Poland (PL) | 38e84872-742f-45b4-96e3-cd0f943799a4 Germany (DE) | 47918f2b-7274-4797-9cb5-9ab23137e18e Sweden (SE) | e32c3249-6834-4c19-ae87-17bfebd384d8 Belgium (BE) | 60e1f36b-d88f-491f-9a80-0a88bde93a1c Hungary (HU)
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration for Electronic Relays and Controls
CB Certificate
CB_DK-8880
CCC Certificate
CCC Certificate - Measuring and Monitoring Relays CM-E range
CQC Certificate
CQC Certificate, Electronic Measuring and Monitoring Relays, CM-PFE, CM-PVE, CM-PBE, CM-MSE, CM-ENE MAX, CM-ENE MIN, Made in Bulgaria
cUL Certificate
cUL508_E140448
Declaration of Conformity - CCC
CCC Declaration of Conformity, Electronic Measuring and Monitoring Relays, CM-PFE, CM-PVE, CM-PBE, CM-MSE, CM-ENE MAX, CM-ENE MIN, Made in Bulgaria
Declaration of Conformity - CE
EU Declaration of Conformity - CM-ENE MIN, CM-ENE MAX Liquid level monitoring relay
Declaration of Conformity - UKCA
UK Declaration of Conformity - CM-ENE MIN, CM-ENE MAX Liquid level monitoring relay
UL Certificate
UL Certificate (UL 508) - CT-E, CT-S range time relays, CM and C51x range measuring and monitoring relays , C57x and C67xx range safety relays, CC-U range analog signal converters with relay output
Package Level 1 Units
box 1 piece
Package Level 1 Width
23 mm
Package Level 1 Depth / Length
82 mm
Package Level 1 Height
82 mm
Package Level 1 Gross Weight
0.118 kg
Package Level 1 EAN
4013614349928
Object Classification Code
B
ETIM 7
EC001447 - (Fill) level monitoring relay
ETIM 8
EC001447 - (Fill) level monitoring relay
ETIM 9
EC001447 - (Fill) level monitoring relay
eClass
V11.0 : 27371813
UNSPSC
39122331
E-Number (Finland)
2712852
E-Number (Norway)
4187266
E-Number (Sweden)
3860803
Feature: 24 V AC rated control supply enables straightforward integration into standard control panels. Benefit: Reduces wiring complexity and allows reliable interfacing with existing automation architectures. Application: Ideal for compact pump stations and process line panels where a standard control voltage is required. Feature: 1 normally open contact (1 n/o) provides a simple, isolated switch output. Benefit: Directly drives pumps, relays, or PLC input cards with predictable switching behavior. Application: Suitable for dry-run protection circuits in water and wastewater systems. Feature: Fixed sensitivity 0–100 kΩ ensures compatibility with a wide range of level sensors. Benefit: Greater sensing flexibility reduces sensor replacement costs and shortens commissioning time. Application: Level monitoring with two-electrode probes in mildly conductive media. Feature: Two electrodes and screw terminals simplify wiring and improve reliability. Benefit: Robust, vibration-tolerant connections; easy field maintenance. Application: OEM panel installations requiring solid electrical contacts. Feature: DIN rail mounting (TH35-15 or TH35-7.5) and compact form factor. Benefit: Fast installation, standardized mounting across machines, and space savings. Application: Modern control cabinets with limited chassis depth. Feature: IP housing protection (IP50) and 4 kV impulse withstand. Benefit: Enhanced reliability in industrial environments with electrical noise and dust exposure. Application: Machinery and plant floors with demanding conditions. Feature: UL 508, CE, and UKCA certifications with RoHS compliance. Benefit: Regulatory readiness for global deployment and streamlined procurement. Application: Compliance-heavy markets in North America and Europe with environmental and safety requirements.

Get a Quick Quote for a ABB 1SVR550855R9500

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SVR550855R9500? Enquire Now

FAQs

To install, mount the unit on a TH35 DIN rail (TH35-15 or TH35-7.5) in the control panel. Connect the 24 V AC supply to the device’s power terminals and wire the two electrodes to the sensing circuit (0–100 kΩ range). Use screw terminals for secure, vibration-resistant connections and follow standard wiring practices for safety and reliability.
The CM-ENE MIN uses 24 V AC control, with an output of 1 normally open contact. Rated operational currents are AC-12 at 4 A and AC-15 at 3 A (230 V). For DC, Ie is 4 A (DC-12, 24 V) and 2 A (DC-13, 24 V). It supports up to 300 V AC on the output circuit under UL/CSA, with RoHS-compliant construction.
Yes. It is specifically designed for draining monitoring and dry-running protection, using a 0–100 kΩ sensing range across two electrodes to detect low liquid levels and trigger the NO contact to stop or start pumps, thereby preventing pump burnout and reducing maintenance needs.
The unit is UL 508 listed and CE marked, with UKCA compliance and RoHS conformity. It also aligns with CAN/CSA C22.2 No.14, IEC/EN 63000, IEC/EN 61000-6-2, and IEC/EN 61000-6-3, ensuring broad regulatory readiness for global deployment.
By preventing dry-running events, the CM-ENE MIN reduces unscheduled downtime and extends pump life. Its straightforward DIN-rail installation and screw-terminal wiring simplify maintenance, while compatibility with common level sensors minimizes sensor replacement costs and accelerates commissioning in multi-site pump systems.