ABB 1TNT7131010I42004 Moulded Case Circuit Breaker - Tmax T
Part Number: 1TNT7131010I42004
Quick Summary
ABB 1TNT7131010I42004 Moulded Case Circuit Breaker is a protective device that safeguards industrial power distributions by quickly interrupting fault currents. Engineers and procurement teams often struggle with integration timelines and regulatory compliance when sourcing MCCBs for critical panels. This model carries RoHS and REACH declarations, a CMRT conflict minerals report, and WEEE categorization to support responsible sourcing and end-of-life planning. Built for the SACE Tmax T family, it combines a compact footprint with robust protection, enabling scalable deployments across new builds or retrofits while keeping maintenance straightforward. Its 1000 A, 4-pole configuration fits medium- to high-load feeders in industrial facilities, machine rooms, and process lines.
Product Information
Environmental Product Declaration - EPD
NoDecNee
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Environmental Information
Product Environmental Information Tmax T7 | Breakers - Packaging disposal information
Customs Tariff Number
853620
Product Net Width
280 mm
Product Net Height
268 mm
Product Net Depth / Length
178 mm
Product Net Weight
14 kg
Package Level 1 Width
360 mm
Package Level 1 Height
350 mm
Package Level 1 Depth / Length
360 mm
Package Level 1 Gross Weight
15.5 kg
Product Main Type
SACE Tmax T
Product Name
Moulded Case Circuit Breaker
Data Sheet, Technical Information
SACE Tmax. T Generation. Low voltage moulded-case circuit-breakers from 250 A up to 1600 A
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
The device provides a high current protection solution with In equal to 1000 A and a compact 280 mm wide footprint, enabling efficient panel space utilization and reliable fault interruption, which reduces downtime and improves overall plant availability. This MCCB belongs to the SACE Tmax T family, designed for low voltage protection from 250 A to 1600 A, offering a scalable protection platform that simplifies spare parts management and standardizes panel protection across multiple lines. Compliance is a core benefit here, with RoHS and REACH declarations plus CMRT reporting and WEEE categorization that streamline supplier qualification, regulatory audits, and corporate sustainability programs. Dimensions and weight—280 mm width, 268 mm height, 178 mm depth, and 14 kg—facilitate precise installation planning and mounting within standard switchgear enclosures, while packaging data support safe, cost-effective shipping. Documentation such as the data sheet on Tmax T generation aids engineers in specification and maintenance planning, reducing risk during retrofits and new builds. Overall, the combination of performance, compliance, and clear packaging details translates to measurable total cost of ownership reductions and faster project execution.
Get a Quick Quote for a ABB 1TNT7131010I42004
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1TNT7131010I42004?
Enquire Now
FAQs
Yes. This Moulded Case Circuit Breaker from the SACE Tmax T family is designed for integration into typical low-voltage panel boards and distribution cabinets. With a 4-pole configuration and In=1000 A rating, it fits mid- to high-load feeder protections commonly specified in industrial control panels. Ensure mounting provisions and busbar layouts align with the 280 mm width and 178 mm depth to maintain proper clearances and fault clearance paths.
Key specs include current rating In=1000 A and a 4-pole configuration within the SACE Tmax T family for low-voltage protection. The unit weighs 14 kg and measures 280 mm wide by 268 mm high by 178 mm deep, with a packaging footprint of 360 mm-related dimensions for freight planning. These specifications support reliable interruption of fault currents in demanding industrial environments and facilitate consistent protective coordination with upstream devices.
This MCCB is well suited for industrial power distribution, machine rooms, and process lines requiring robust 1000 A protection across multiple feeders. Its Tmax T lineage supports scalable deployment from 250 A up to 1600 A, making it appropriate for either new-build panels or retrofits where consistent protection standards and a unified maintenance approach are desired.
The product includes RoHS Declaration, REACH Declaration, CMRT (Conflict Minerals Reporting Template), and WEEE categorization. These documents help ensure regulatory compliance, supplier risk management, and sustainability reporting, while simplifying audits and end-of-life planning for industrial procurement programs. They are particularly relevant for customers pursuing global procurement standards and responsible sourcing initiatives.
Maintenance considerations include leveraging the Tmax T data sheet for installation and service guidance, and using its standardized 4-pole configuration to streamline spare parts and technician training. The high current rating and reliable protection reduce unplanned downtime, delivering a favorable ROI by extending equipment uptime, simplifying panel maintenance, and reducing total cost of ownership over the product’s lifecycle.