ABB 2CLA226210N1501 Time Switch - Zenit S Matt Black
Part Number: 2CLA226210N1501
Quick Summary
ABB 2CLA226210N1501 Time Switch enables precise timed control for lighting and small motor loads in domestic and light industrial applications. Users often wrestle with mis-timed events, flicker, or energy waste when timers aren’t consistent; this device delivers repeatable, adjustable delays from 10 seconds to 10 minutes to combat that. It aligns with CMRT, WEEE category 5, and ETIM 9 EC001594 for responsible sourcing and regulatory assurance. Designed for Zenit S housing and 230 VAC networks, it offers a compact 2-module footprint, LED status indicator, and straightforward installation to maximize uptime, reduce energy waste, and simplify maintenance for facilities and technical teams.
Product Information
Extended Description
2CLA226210N1501 ABB: Color: Matt Black.
Rated voltage: 230 Vac / 50 Hz
Power:
- Incandescent: 40 - 500 W
- Halogen with transformer: 40 - 400 VA
- Motors: 40 - 100 VA
2 wire connection
Delay setup: 10 sec. to 10 min.
Overcurrent protection: with fuse
Indicator LED lamp included
Operating temperature: 0 - 40ºC
Size: 2 modules.
Instructions and Manuals
Manual - Timer switch - N2262.1 / 8162.1 / 2262.1
Data Sheet, Technical Information
9AKK10103A5108
Design Range
Zenit
Design Range Variant
Zenit S
Color
Matt Black
Conflict Minerals Reporting Template (CMRT)
Conflict Minerals Reporting Template
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
WEEE B2C / B2B
Business To Consumer
ETIM 9
EC001594 - Time switch clock for domestic switching devices
UNSPSC
39122226
Feature → Business Impact → Application: The 230 VAC / 50 Hz rated supply is compatible with standard mains, enabling immediate deployment in existing electrical panels without additional power transitions, reducing wiring changes and commissioning time for lighting and small motor circuits. This supports faster project delivery and lower installation costs in both residential refurbishments and light commercial spaces. Feature → Business Impact → Application: Load ranges accommodate incandescent (40-500 W), halogen with transformer (40-400 VA), and small motors (40-100 VA), delivering flexible scheduling across diverse tasks from room lighting to fan control and small process motors, minimizing over- or under-sizing while preserving reliability in critical scheduling windows. Feature → Business Impact → Application: Delay setting from 10 seconds to 10 minutes enables precise sequencing of on/off events, improving energy efficiency and extending equipment life by avoiding immediate start-stop cycles in lighting and pump applications found in workshops and back-of-house zones. Feature → Business Impact → Application: 2-wire connection and 2-module footprint simplify retrofits and new installations, allowing panel gains and easier accessible mounting in compact enclosures, which reduces field errors and accelerates commissioning. Feature → Business Impact → Application: Overcurrent protection with fuse and an LED indicator provide immediate fault awareness and protection, enabling proactive maintenance and safer operation for all light control and small motor circuits in commercial and industrial environments. Feature → Business Impact → Application: Zenit S design with Matt Black finish supports aesthetic integration in modern interiors and equipment rooms, while CMRT, WEEE compliance, and ETIM 9 classification ensure supply-chain transparency and regulatory alignment for procurement and compliance teams. Feature → Business Impact → Application: Operating range 0–40°C ensures stable performance in typical indoor environments, while a compact 2-module size supports space-constrained panels and retrofits, enhancing installation flexibility and reducing enclosure extensions in industrial control panels.
Get a Quick Quote for a ABB 2CLA226210N1501
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 2CLA226210N1501?
Enquire Now
FAQs
The timer is designed for a 2-wire connection to standard 230 V AC mains. Mount the unit in a compatible Zenit S enclosure, connect the live feed to the input terminal and the load to the output terminal, and ensure the device is within the 0–40°C operating range. No neutral is required for basic operation, and verify a 2-module footprint fits your panel space.
Load ranges include incandescent 40–500 W, halogen with transformer 40–400 VA, and motors 40–100 VA. Select the setting based on the largest connected load, and avoid exceeding the specified VA/W limits. This ensures reliable switching without nuisance tripping and extends life for connected devices.
Yes. The Zenit S design, 230 VAC operation, and broad load range make it ideal for domestic lighting control and small motor sequencing in workshops and light commercial spaces. Its adjustable delay (10 seconds to 10 minutes) supports scheduling for lighting scenes and equipment cooling cycles.
The product adheres to CMRT for conflict minerals reporting, WEEE Category 5 for small equipment, and ETIM 9 EC001594 classification as a time switch clock for domestic devices. These align procurement and regulatory requirements for responsible sourcing and end-to-end compliance.
By delivering precise delays and reliable operation, the timer reduces energy waste and minimizes stand-by or inadvertent on-times, lowering utility costs. The LED indicator aids quick fault diagnosis, reducing maintenance downtime, and the 2-module form factor simplifies retrofits and replacements, delivering faster installation and a lower total cost of ownership.