ABB 2TFC000590R1001 Moulded Case Circuit Breaker - EPD Tmax XT

Part Number: 2TFC000590R1001
Manufacturer
ABB
Part number
2TFC000590R1001

Quick Summary

ABB 2TFC000590R1001 Moulded Case Circuit Breaker protects low‑voltage switchgear from overload and short‑circuit events. In dense electrical cabinets, mismatched ratings and long lead times drive downtime and increase risk. This device complies with IEC 60947-2, CE conformity, and RoHS, with an environmental impact profile documented by the EPD Tmax XT program. Designed for Tmax XT families and the Ekip M Dip LIU releases, it streamlines procurement, maintenance, and compliance across industrial installations. The combination of fixed three‑pole design, front terminals, and LIU release supports fast integration in control panels and reduces field wiring complexity. Engineers benefit from clear environmental and safety declarations that simplify supplier qualification and regulatory reviews.

Product Information

Extended Description

2TFC000590R1001 ABB: C.BREAKER TMAX XT2H160 FIXED THREE-POLE WITH FRONT TERMINALS AND SOLID-STATE RELEASE IN AC EKIP M Dip LIU R 160 A
Environmental Product Declaration - EPD
EPD Tmax XT XT2 ELT (IT)
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
Document availability on demand
Environmental Information
Product Environmental Information Tmax XT
Customs Tariff Number
85362000
Product Net Width
90 mm
Product Net Height
130 mm
Product Net Depth / Length
82.5 mm
Product Net Weight
1.2 kg
Product Name
Moulded Case Circuit Breaker
Product Type
CB
Version
F
Current Type
AC
Electrical Durability
8000 cycle | 120 cycles per hour
Mechanical Durability
25000 cycle | 240 cycles per hour
Number of Poles
3P
Power Loss
at Rated Operating Conditions per Pole 10.80 W
Rated Current (In)
160 A
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Insulation Voltage (Ui)
1000 V
Rated Operational Voltage
690 V AC | 500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 100 kA | (230 V AC) 100 kA | (240 V AC) 100 kA | (380 V AC) 70 kA | (415 V AC) 70 kA | (440 V AC) 65 kA | (500 V AC) 50 kA | (525 V AC) 30 kA | (690 V AC) 15 kA | (250 V DC) 2 Poles in Series 70 kA | (500 V DC) 3 Poles in Series 70 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(220 V AC) 100 kA | (230 V AC) 100 kA | (240 V AC) 100 kA | (380 V AC) 70 kA | (415 V AC) 70 kA | (440 V AC) 65 kA | (500 V AC) 50 kA | (525 V AC) 30 kA | (690 V AC) 15 kA | (250 V DC) 2 Poles in Series 70 kA | (500 V DC) 3 Poles in Series 70 kA
Rated Uninterrupted Current (Iu)
160 A
Release
Ekip M Dip LIU
Release Type
EL
Short-Circuit Performance Level
H
Standards
IEC 60947-2 | GB/T 14028.2
Sub-type
XT2
Terminal Connection Type
Fixed Circuit-Breakers
Data Sheet, Technical Information
SACE Tmax XT IEC Low voltage molded case circuit-breakers Catalog | SACE Tmax XT IEC TECHNICAL CHARACTERISTICS Low voltage molded case circuit-breakers
Declaration of Conformity - CE
EC Declaration of Conformity Tmax XT2
Instructions and Manuals
Installation Instructions XT2 | Release assembly XT2-XT4 | Release Ekip G-LS/I, Ekip N-LS/I, Ekip M-LIU, Ekip M-I XT2-XT4
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
Three-pole fixed construction with front terminals simplifies wiring and serviceability, cutting field wiring time and reducing misconnection risk in panel boards. This translates to faster commissioning and easier maintenance in control cabinets and motor feeders, delivering measurable uptime improvements. The Ekip M Dip LIU release provides reliable tripping performance, enabling selective protection and safer shutdowns in real‑world conditions. In practice, teams experience lower fault investigation costs and quicker fault isolation, thanks to clear trip characteristics and standardized replacement parts within the Tmax XT ecosystem. The device meets IEC 60947-2 and RoHS/REACH requirements, supporting compliant procurement and smoother regulatory reviews. Its dimensions (90 mm width, 130 mm height, 82.5 mm depth) and 1.2 kg weight enable compact fitment in standard 3P enclosures, with front‑terminal access that reduces wiring errors during installation. This makes it ideal for panel builders seeking robust protection with straightforward field service.

Get a Quick Quote for a ABB 2TFC000590R1001

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 2TFC000590R1001? Enquire Now

FAQs

Plan for a 90 mm wide, 130 mm high space with at least 82.5 mm depth. Use the front terminal connections for quicker wiring and safer maintenance, ensuring torque values match the manufacturer's specification. Confirm clearances around the breaker to accommodate 690 VAC line voltage and allow accessible wiring routes to minimize thermal buildup and accidental contact.
The breaker is rated for 160 A and 690 VAC (500 V DC). It provides a rated impulse withstand voltage of 8 kV and a service short‑circuit breaking capacity Ics typically up to 70–100 kA depending on the voltage. Ui is 1000 V, with a three‑pole configuration designed for reliable protection in low‑voltage switchgear.
Yes. The XT2 family with Ekip M Dip LIU release is designed for rugged industrial environments, including automation lines in manufacturing. Its 160 A rating, three‑pole fixed design, and front terminals support fast integration, while RoHS/REACH compliance and the EPD Tmax XT data help meet strict regulatory and sustainability requirements common in automotive and packaging applications.
This breaker complies with IEC 60947-2 and GB/T 14028.2, with CE conformity declarations and RoHS/REACH compliance. It is supported by product environmental information (EPD Tmax XT) and DoC documentation, simplifying supplier qualification, conformity assessments, and regulatory reviews for procurement teams.
Electrical durability is rated at up to 8000 cycles and 120 cycles per hour, while mechanical durability reaches 25000 cycles at 240 cycles per hour. This translates to longer service intervals, reduced maintenance costs, and lower downtime in production lines, delivering a favorable return on investment through fewer field replacements and quicker fault resolution.