ABB 2TFH100002R1001 Moulded Case Circuit Breaker - IEC60947-2
Part Number: 2TFH100002R1001
Quick Summary
ABB 2TFH100002R1001 Moulded Case Circuit Breaker is designed to protect low-voltage circuits in industrial panels. Engineers often grapple with panel space, reliability, and regulatory compliance when selecting protective devices. This model supports IEC60947-2 and GB/T 14028.2 standards, with CE declarations plus RoHS and REACH compliance to streamline audits. As part of the SACE Tmax XT family, it offers a compact footprint and front-terminal access, enabling quicker installation and safer maintenance in control cabinets. The device aligns with 690 V AC and 500 V DC operational ranges, supporting versatile automation applications across manufacturing lines.
Product Information
Extended Description
2TFH100002R1001 ABB: XT1B160 TMD20/450 FFC 3P
Environmental Product Declaration - EPD
NoDecNee
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Environmental Information
Breakers - Packaging disposal information
Customs Tariff Number
85362000
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Version
F
Current Type
AC/DC
Electrical Durability
8000 cycle | 120 cycles per hour
Mechanical Durability
25000 cycle | 240 cycles per hour
Number of Poles
3P
Power Loss
at Rated Operating Conditions per Pole 1.8 W
Rated Current (In)
20 A
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Insulation Voltage (Ui)
800 V
Rated Operational Voltage
690 V AC | 500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 25 kA | (230 V AC) 25 kA | (240 V AC) 25 kA | (380 V AC) 18 kA | (415 V AC) 18 kA | (440 V AC) 11.5 kA | (500 V AC) 8 kA | (525 V AC) 6 kA | (690 V AC) 3 kA | (250 V DC) 2 Poles in Series 18 kA | (500 V DC) 3 Poles in Series 18 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(220 V AC) 25 kA | (230 V AC) 25 kA | (240 V AC) 25 kA | (380 V AC) 18 kA | (415 V AC) 18 kA | (440 V AC) 15 kA | (500 V AC) 8 kA | (525 V AC) 6 kA | (690 V AC) 3 kA | (250 V DC) 2 Poles in Series 18 kA | (500 V DC) 3 Poles in Series 18 kA
Rated Uninterrupted Current (Iu)
160 A
Release
TMD
Release Type
TM
Remarks
ATLAS
Short-Circuit Performance Level
B
Standards
IEC60947-2 | GB/T 14028.2
Sub-type
XT1
Terminal Connection Type
Front for Copper Cables
Data Sheet, Technical Information
SACE Tmax XT IEC Low voltage molded case circuit-breakers Catalog | SACE Tmax XT IEC TECHNICAL CHARACTERISTICS Low voltage molded case circuit-breakers
Declaration of Conformity - CE
EC Declaration of Conformity Tmax XT1
Instructions and Manuals
Installation instructions XT1
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
Feature → 3P, 20 A rated current with front-terminal copper connections. Business Impact → Provides predictable protection for small-to-moderate loads while simplifying wiring and field maintenance. Application → Ideal for machine panels and process lines where space is at a premium and quick service is essential. Feature → 8 kV rated impulse withstand voltage (Uimp) and up to 25 kA short-circuit breaking capacity (Ics/Icu) across multiple voltages. Business Impact → Enhances system resilience against transients and ensures reliable shutdown during faults, reducing downtime. Application → Suitable for demanding industrial distribution boards and critical control circuits. Feature → Wide rated operational envelope 690 V AC / 500 V DC with 800 V rated insulation. Business Impact → Enables cross-voltage protection in mixed AC/DC environments, decreasing part counts. Application → Supports modern automation architectures and energy storage interfaces. Feature → Release type TM within the SACE Tmax XT family; compact form factor. Business Impact → Streamlines panel design and reduces enclosure footprint while maintaining safety margins. Application → Fits standard MCCB deployments in automation cabinets and motor control centers. Feature → Front-for-copper-cables terminal connection and modular mounting compatibility. Business Impact → Improves installation speed and wiring reliability, lowering commissioning time. Application → Ideal for retrofit projects and new builds in OEM and end-user facilities. Feature → RoHS and REACH declarations with CMRT and packaging disposal guidance. Business Impact → Supports regulatory compliance and sustainability goals, simplifying supplier audits. Application → Useful for global deployments across regulated markets where material transparency matters.
Get a Quick Quote for a ABB 2TFH100002R1001
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 2TFH100002R1001?
Enquire Now
FAQs
This model uses front-for-copper-cables terminals, which simplifies wiring in enclosed control cabinets and reduces wiring length. Ensure copper conductors are properly stripped to the manufacturer’s recommended length, tighten terminals to the specified torque, and verify accessibility for future maintenance while preserving the device’s protection performance.
Yes. The 2TFH100002R1001 adheres to IEC60947-2 with a rated operational range of 690 V AC and 500 V DC. It is designed for three-phase distribution in industrial environments, delivering reliable protection and predictable tripping performance in compliant panels.
The device provides high short-circuit protection with a rated service breaking capacity up to 25 kA across multiple voltages and configurations. Typical values vary by voltage, aligning with 220–240 V and higher voltage categories, ensuring robust protection for motor feeders and distribution circuits.
Yes. The product includes RoHS information and REACH declarations to support regulatory compliance in diverse markets. This makes it suitable for projects requiring material transparency and reduced hazardous substances in electrical components.
This MCCB is part of the SACE Tmax XT family, with release TM and product type automatic circuit breaker. It also lists packaging, customs tariff code, and standards alignment, aiding compatibility checks, retrofits, and ongoing maintenance within standard ABB panel solutions.