ABB 2TFH100042R1001 Moulded Case Circuit Breaker - 8 kV

Part Number: 2TFH100042R1001
Manufacturer
ABB
Part number
2TFH100042R1001

Quick Summary

ABB 2TFH100042R1001 Moulded Case Circuit Breaker protects electrical circuits in industrial power distribution applications. Engineers often wrestle with balancing compact size, reliable fault current interruption, and easy maintenance in control panels. This XT Tmax XT MCCB family delivers 8 kV impulse withstand, 690 V AC operation, and 32 A nominal current, backed by CE, RoHS, and CMRT declarations. RoHS, REACH, and CMRT provide regulatory confidence and waste-compliance clarity for global installations. In practice, customers enjoy safer panels, lower energy losses (2.1 W per pole), and simpler installation thanks to front‑connected copper terminals and a three‑pole, TM release design.

Product Information

Extended Description

2TFH100042R1001 ABB: XT1C160 TMD32/450 FFC 3P
Environmental Product Declaration - EPD
NoDecNee
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Environmental Information
Breakers - Packaging disposal information
Customs Tariff Number
85362000
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Version
F
Current Type
AC/DC
Electrical Durability
8000 cycle | 120 cycles per hour
Mechanical Durability
25000 cycle | 240 cycles per hour
Number of Poles
3P
Power Loss
at Rated Operating Conditions per Pole 2.1 W
Rated Current (In)
32 A
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Insulation Voltage (Ui)
800 V
Rated Operational Voltage
690 V AC | 500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 40 kA | (230 V AC) 40 kA | (240 V AC) 40 kA | (380 V AC) 25 kA | (415 V AC) 25 kA | (440 V AC) 12.5 kA | (500 V AC) 9 kA | (525 V AC) 8 kA | (690 V AC) 4 kA | (250 V DC) 2 Poles in Series 25 kA | (500 V DC) 3 Poles in Series 25 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(220 V AC) 40 kA | (230 V AC) 40 kA | (240 V AC) 40 kA | (380 V AC) 25 kA | (415 V AC) 25 kA | (440 V AC) 25 kA | (500 V AC) 18 kA | (525 V AC) 8 kA | (690 V AC) 4 kA | (250 V DC) 2 Poles in Series 25 kA | (500 V DC) 3 Poles in Series 25 kA
Rated Uninterrupted Current (Iu)
160 A
Release
TMD
Release Type
TM
Remarks
ATLAS
Short-Circuit Performance Level
C
Standards
IEC60947-2 | GB/T 14028.2
Sub-type
XT1
Terminal Connection Type
Front for Copper Cables
Data Sheet, Technical Information
SACE Tmax XT IEC Low voltage molded case circuit-breakers Catalog | SACE Tmax XT IEC TECHNICAL CHARACTERISTICS Low voltage molded case circuit-breakers
Declaration of Conformity - CE
EC Declaration of Conformity Tmax XT1
Instructions and Manuals
Installation instructions XT1
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
Rated current and voltage align with typical industrial loads; this MCCB handles 32 A at up to 690 V AC, enabling compact panel layouts and safer wiring. The device also features high insulation (Ui 800 V) and 8 kV impulse withstand, delivering reliable protection in demanding environments and reducing nuisance trips. Short-circuit performance is rated up to 40 kA for Ics/Icu depending on supply voltage, providing dependable interruption during faults and limiting downstream damage. Durability is strong—25,000 mechanical cycles and 8,000 electrical cycles—meaning longer service intervals and lower maintenance costs in high-use applications. Front terminal connections for copper cables simplify wiring, accelerate panel assembly, and reduce wiring errors. The TM release with XT1 sub-type delivers predictable tripping behavior, while RoHS and REACH declarations support compliant global installations. At a system level, power loss is 2.1 W per pole, contributing to cooler enclosures and better energy efficiency over the device lifetime. As part of the SACE Tmax XT family, it integrates smoothly with ABB protection architectures and simplifies upgrades or replacements.

Get a Quick Quote for a ABB 2TFH100042R1001

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 2TFH100042R1001? Enquire Now

FAQs

Install with front copper cable terminals in a three-pole arrangement for compact panels. Ensure correct torque on lugs per installation instructions, align with 690 V AC rating, and use the TM release for tripping coordination. The XT1 form factor supports standard DIN rail or panel-mount configurations without adapters, reducing commissioning time.
Rated current is 32 A, rated operational voltage is 690 V AC (500 V DC), Ui is 800 V, and Uimp is 8 kV. Short-circuit ratings vary by voltage level, with Ics up to 40 kA at certain voltages and Icu up to 40 kA for designated configurations, ensuring robust protection in industrial feeders.
Yes, it is designed for demanding industrial applications as part of the SACE Tmax XT family, with IEC60947-2 compliance and robust RoHS/REACH declarations. While exact IP rating isn’t listed here, the device’s rugged design and high short-circuit capability make it suitable for control panels, process lines, and machine enclosures with standard protection practices.
The product includes CE Declaration of Conformity, RoHS information, REACH declaration, and CMRT for conflict minerals reporting. WEEE category information is provided for packaging disposal. These certifications support regulatory compliance and sustainability reporting across multiple regions.
Electrical durability is rated at 8,000 cycles and mechanical durability at 25,000 cycles, reducing maintenance downtime. With 2.1 W per pole power loss and reliable fault interruption, you gain improved uptime, lower energy costs, and simpler maintenance planning, contributing to a favorable total cost of ownership in continuous-operation environments.