ABB 2TFH100143R1001 Moulded Case Breaker - IEC60947-2

Part Number: 2TFH100143R1001
Manufacturer
ABB
Part number
2TFH100143R1001

Quick Summary

ABB 2TFH100143R1001 Moulded Case Breaker is a robust four-pole protection device engineered for reliable low-voltage distribution in industrial switchgear. Operators often face nuisance trips and wiring complexity that slow start-ups and maintenance; this XT1-based breaker delivers consistent trip performance, rapid fault clearance, and straightforward front-terminal installation to reduce downtime. It aligns with key standards to simplify regulatory compliance, including IEC60947-2 and GB/T 14028.2, and carries CE declarations alongside RoHS and REACH information for global applicability. With CMRT and environmental considerations in place, you gain predictable performance, safer commissioning, and a clear path to scalable protection across power distribution networks. The device also supports 690 V AC and 500 V DC applications, enhancing project flexibility for growing automation systems.

Product Information

Extended Description

2TFH100143R1001 ABB: XT1S160 TMD80/800 FFC 4P
Environmental Product Declaration - EPD
NoDecNee
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Environmental Information
Breakers - Packaging disposal information
Customs Tariff Number
85362000
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Version
F
Current Type
AC/DC
Electrical Durability
8000 cycle | 120 cycles per hour
Mechanical Durability
25000 cycle | 240 cycles per hour
Number of Poles
4P
Power Loss
at Rated Operating Conditions per Pole 4.8 W
Rated Current (In)
80 A
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Insulation Voltage (Ui)
800 V
Rated Operational Voltage
690 V AC | 500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 63.75 kA | (230 V AC) 63.75 kA | (240 V AC) 63.75 kA | (380 V AC) 50 kA | (415 V AC) 37.5 kA | (440 V AC) 25 kA | (500 V AC) 18 kA | (525 V AC) 17.5 kA | (690 V AC) 5 kA | (250 V DC) 2 Poles in Series 50 kA | (500 V DC) 3 Poles in Series 50 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(220 V AC) 85 kA | (230 V AC) 85 kA | (240 V AC) 85 kA | (380 V AC) 50 kA | (415 V AC) 50 kA | (440 V AC) 50 kA | (500 V AC) 36 kA | (525 V AC) 35 kA | (690 V AC) 8 kA | (250 V DC) 2 Poles in Series 50 kA | (500 V DC) 3 Poles in Series 50 kA
Rated Uninterrupted Current (Iu)
160 A
Release
TMD
Release Type
TM
Short-Circuit Performance Level
S
Standards
IEC60947-2 | GB/T 14028.2
Sub-type
XT1
Terminal Connection Type
Front for Copper Cables
Data Sheet, Technical Information
SACE Tmax XT IEC Low voltage molded case circuit-breakers Catalog | SACE Tmax XT IEC TECHNICAL CHARACTERISTICS Low voltage molded case circuit-breakers
Declaration of Conformity - CE
EC Declaration of Conformity Tmax XT1
Instructions and Manuals
Installation instructions XT1
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
Feature → Business Impact → Application: 4P XT1 molded case design provides comprehensive multi-pole protection in compact footprints, enabling cleaner panel layouts and easier wiring harness management; reduces panel size requirements while improving protection coverage for motors and drives. Application: MCCs and motor control centers benefit from streamlined installation and space optimization. Feature → Business Impact → Application: Rated current of 80 A with high Ics values delivers reliable fault interruption under peak loading, lowering the risk of downstream equipment damage and unplanned downtime; supports safer startup and smoother load transitions. Application: Process lines with variable loads and peak demand. Feature → Business Impact → Application: Rated operational voltage of 690 V AC / 500 V DC and 800 V insulation withstand enable broad regional use and compatibility with mixed-power systems; simplifies engineering standards and reduces part numbers. Application: Plant-wide distribution in mixed-voltage environments. Feature → Business Impact → Application: Front terminals for copper cables offer quick, secure connections and easy re-termination during panel upgrades; reduces installation time and field wiring errors. Application: Retrofit projects and new panel builds. Feature → Business Impact → Application: RoHS and REACH declarations along with CMRT streamline supplier compliance audits and sustainability reporting; lowers risk during procurement and regulatory reviews. Application: Corporate ESG reporting and risk management. Feature → Business Impact → Application: 4.8 W power loss per pole provides efficient operation with predictable thermal behavior, aiding cooling design and energy cost control; reduces total cost of ownership. Application: Data centers, manufacturing floors, and process plants where heat and energy budgets are critical. Feature → Business Impact → Application: International standards conformance (IEC60947-2, GB/T 14028.2) ensures compatibility across global projects and machine builders; simplifies sourcing and reduces customization needs. Application: Global rollouts and multi-site installations.

Get a Quick Quote for a ABB 2TFH100143R1001

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 2TFH100143R1001? Enquire Now

FAQs

Follow standard MCCB installation guidelines: mount the unit securely, connect copper conductors to the front terminals as specified, ensure correct alignment with busbars, and verify voltage ratings (690 VAC / 500 V DC). Use appropriate torque settings for copper cables and check insulation distances per IEC60947-2. This minimizes contact resistance and ensures reliable fault interrupting performance.
The device is rated for 80 A with an operational voltage of 690 V AC and 500 V DC. It offers a rated service short-circuit breaking capacity (Ics) up to 63.75 kA across common voltages and a rated ultimate short-circuit breaking capacity (Icu) up to 85 kA in selected configurations, supporting robust protection in demanding industrial networks.
Yes. The product carries RoHS information and a REACH declaration for ABB Sace circuit breakers, plus a CMRT for conflict minerals reporting, ensuring global compliance and easier supplier audits during international deployments.
Standards include IEC 60947-2 and GB/T 14028.2. This makes the XT1 4P suitable for global low-voltage distribution panels, motor control centers, and process equipment in both European and Asian markets, with CE conformity supporting worldwide installations.
Ideal for motor control centers, switchboards, and process lines requiring reliable short-circuit protection, compact footprint, and quick installation. Its 4P design, front-terminal copper connections, and high breaking capacities support scalable protection across power distribution networks while meeting regulatory and sustainability requirements.