ABB 2TFH100557R1001 SACE Tmax XT1 - 8 kV

Part Number: 2TFH100557R1001
Manufacturer
ABB
Part number
2TFH100557R1001

Quick Summary

ABB 2TFH100557R1001 is a three-pole molded case circuit breaker protecting industrial motor and distribution circuits. In practice, engineers face nuisance trips and limited fault margins during commissioning and daily operations. This device delivers robust protection with a rated current of 80 A and a rated operating voltage up to 690 V AC / 500 V DC, while maintaining high short-circuit capability for dependable system safety. It carries IEC60947-2 and GB/T 14028.2 standards, and is supported by CE conformity, plus RoHS and REACH declarations for compliant procurement. For panel builders and OEMs, plug-in compatibility and the XT1 design streamline retrofit projects, reducing install time and wiring complexity while boosting overall reliability and lifecycle cost savings.

Product Information

Extended Description

2TFH100557R1001 ABB: XT1H160 TMD80/800 PMP 3P
Environmental Product Declaration - EPD
NoDecNee
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Environmental Information
Breakers - Packaging disposal information
Customs Tariff Number
85362000
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Version
P
Current Type
AC/DC
Electrical Durability
8000 cycle | 120 cycles per hour
Mechanical Durability
25000 cycle | 240 cycles per hour
Number of Poles
3P
Power Loss
at Rated Operating Conditions per Pole 7.2 W
Rated Current (In)
80 A
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Insulation Voltage (Ui)
800 V
Rated Operational Voltage
690 V AC | 500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 75 kA | (230 V AC) 75 kA | (240 V AC) 75 kA | (380 V AC) 52.5 kA | (415 V AC) 37.5 kA | (440 V AC) 32.5 kA | (500 V AC) 25 kA | (525 V AC) 17.5 kA | (690 V AC) 5 kA | (250 V DC) 2 Poles in Series 52.5 kA | (500 V DC) 3 Poles in Series 52.5 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(220 V AC) 100 kA | (230 V AC) 100 kA | (240 V AC) 100 kA | (380 V AC) 70 kA | (415 V AC) 70 kA | (440 V AC) 65 kA | (500 V AC) 50 kA | (525 V AC) 35 kA | (690 V AC) 10 kA | (250 V DC) 2 Poles in Series 70 kA | (500 V DC) 3 Poles in Series 70 kA
Rated Uninterrupted Current (Iu)
160 A
Release
TMD
Release Type
TM
Remarks
ATLAS
Short-Circuit Performance Level
H
Standards
IEC60947-2 | GB/T 14028.2
Sub-type
XT1
Terminal Connection Type
Plug-In Circuit-Breakers
Data Sheet, Technical Information
SACE Tmax XT IEC Low voltage molded case circuit-breakers Catalog | SACE Tmax XT IEC TECHNICAL CHARACTERISTICS Low voltage molded case circuit-breakers
Declaration of Conformity - CE
EC Declaration of Conformity Tmax XT1
Instructions and Manuals
Installation instructions XT1
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
The three-pole XT1 design provides consistent, predictable tripping behavior, enhancing equipment protection and reducing unplanned downtime for industrial drives and MCCs. With 80 A nominal current and 690 V AC | 500 V DC operating capability, it supports modern control panels and machine logic without over-specification, delivering cost efficiency during installation and commissioning. Short-circuit performance is reinforced by the rated service Ics and rated ultimate Icu values, giving engineers confidence in fault containment across varying supply voltages. The 7.2 W per pole power loss and durable 8000 electrical cycles / 25000 mechanical cycles translate to lower operating temperatures and longer service life, reducing maintenance costs and extending panel life. RoHS/REACH compliance and CMRT support safer supply chains and regulatory peace of mind. Quick plug-in installation minimizes field wiring and shaves days from retrofit programs, while Customs Tariff 85362000 and WEEE labeling align with global trade and end-of-life requirements. This combination makes the ABB Tmax XT family a reliable choice for high-demand industrial environments.

Get a Quick Quote for a ABB 2TFH100557R1001

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 2TFH100557R1001? Enquire Now

FAQs

Yes. This model uses a plug-in circuit-breaker design compatible with standard XT1-based panels and MCCs, simplifying retrofits and new builds. Verify busbar spacing and torque per installation instructions XT1 to ensure secure connections.
Key ratings include rated current 80 A, rated insulation voltage 800 V, rated operational voltage 690 V AC / 500 V DC, rated impulse withstand voltage 8 kV, and short-circuit capacities Ics up to 75 kA and Icu up to 70–100 kA depending on voltage. These figures support protection for motor loads and distribution circuits.
Yes. It carries the CE Declaration of Conformity and RoHS status in line with EU directives, along with REACH declarations and CMRT for responsible sourcing, ensuring regulatory and supplier compliance.
Ideal for motor protection in MCCs, machine control panels, and distribution boards in manufacturing and processing facilities. Its 3P configuration, plug-in design, and high Ics/Icu ratings support reliable protection in demanding environments.
Electrical durability of 8000 cycles and mechanical durability of 25000 cycles translate to longer service life with fewer interventions. Low power loss per pole (7.2 W) reduces heating, contributing to cooler operation and lower energy costs over time.