ABB 2TFH100579R1001 Moulded Case Circuit Breaker - 8 kV

Part Number: 2TFH100579R1001
Manufacturer
ABB
Part number
2TFH100579R1001

Quick Summary

ABB 2TFH100579R1001 Moulded Case Circuit Breaker protects electrical networks by reliably interrupting fault currents in low‑voltage distributions. Engineers often wrestle with coordinating protection schemes, minimizing nuisance trips, and keeping downtime to a minimum in mixed AC/DC installations. This XT1 family device carries IEC60947-2 compliance along with CE marking, RoHS information, and CMRT reporting to support global sourcing and traceability. Designed for plug‑in installation in panels, it delivers 40 A nominal current, 690 VAC / 500 V DC operation, and durable performance to reduce lifecycle costs in industrial automation. With robust durability and scalable protection, it aligns with modern plant requirements.

Product Information

Extended Description

2TFH100579R1001 ABB: XT1N160 TMD40/450 PMP 4P
Environmental Product Declaration - EPD
NoDecNee
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Environmental Information
Breakers - Packaging disposal information
Customs Tariff Number
85362000
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Version
P
Current Type
AC/DC
Electrical Durability
8000 cycle | 120 cycles per hour
Mechanical Durability
25000 cycle | 240 cycles per hour
Number of Poles
4P
Power Loss
at Rated Operating Conditions per Pole 4.6 W
Rated Current (In)
40 A
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Insulation Voltage (Ui)
800 V
Rated Operational Voltage
690 V AC | 500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 50 kA | (230 V AC) 50 kA | (240 V AC) 50 kA | (380 V AC) 36 kA | (415 V AC) 36 kA | (440 V AC) 18 kA | (500 V AC) 15 kA | (525 V AC) 11 kA | (690 V AC) 5 kA | (250 V DC) 2 Poles in Series 36 kA | (500 V DC) 3 Poles in Series 36 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(220 V AC) 65 kA | (230 V AC) 65 kA | (240 V AC) 65 kA | (380 V AC) 36 kA | (415 V AC) 36 kA | (440 V AC) 36 kA | (500 V AC) 30 kA | (525 V AC) 22 kA | (690 V AC) 6 kA | (250 V DC) 2 Poles in Series 36 kA | (500 V DC) 3 Poles in Series 36 kA
Rated Uninterrupted Current (Iu)
160 A
Release
TMD
Release Type
TM
Remarks
ATLAS
Short-Circuit Performance Level
N
Standards
IEC60947-2 | GB/T 14028.2
Sub-type
XT1
Terminal Connection Type
Plug-In Circuit-Breakers
Data Sheet, Technical Information
SACE Tmax XT IEC Low voltage molded case circuit-breakers Catalog | SACE Tmax XT IEC TECHNICAL CHARACTERISTICS Low voltage molded case circuit-breakers
Declaration of Conformity - CE
EC Declaration of Conformity Tmax XT1
Instructions and Manuals
Installation instructions XT1
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
The four‑pole XT1 design with plug‑in terminals enables rapid installation and seamless protection across all phases, reducing commissioning time and wiring errors in control panels. This translates to faster deployment and lower project risk in automotive, process, and material handling environments. The 40 A rating supports reliable machine protection without overprotecting circuits, improving selectivity and reducing nuisance trips in automated lines. Operating at 690 VAC and 500 V DC with Uimp of 8 kV ensures safe interruption of faults across mixed power systems, enabling cleaner handoffs between power conversion stages and drives. Electrical durability of 8000 cycles and mechanical durability of 25000 cycles extend service life, lowering maintenance costs and downtime during upgrades or refurbishments. Power loss of 4.6 W per pole minimizes heat generation in panels, contributing to cooler enclosures and better overall efficiency. Regulatory compliance is maintained through RoHS, REACH, CMRT, and WEEE disclosures, simplifying global procurement and sustainability reporting. The SACE Tmax XT family compatibility ensures easy replacement and standardized protection across existing installations, supporting scalable upgrades without re‑engineering.

Get a Quick Quote for a ABB 2TFH100579R1001

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 2TFH100579R1001? Enquire Now

FAQs

This 4P plug‑in MCCB is designed for straightforward panel installation. Ensure compatible busbar spacing, secure mounting, and torque specifications per the XT1 installation instructions. Use the plug‑in terminals for quick replacement and verify 690 VAC / 500 VDC operation within rated limits.
The device is rated for 40 A with Ui 800 V and Uimp 8 kV, supporting 690 V AC and 500 V DC operation. Short‑circuit performance varies by voltage, with high‑level protection suitable for standard industrial panels and mixed AC/DC systems.
Yes. The current type is AC/DC, enabling use in mixed powered automation environments such as conveyors, motors, and drives where both AC and DC fault protection is required.
The unit adheres to IEC 60947‑2 and GB/T 14028.2, and carries CE, RoHS, and CMRT declarations, supporting global compliance and responsible sourcing.
Durability figures include 8000 electrical cycles and 25000 mechanical cycles, reducing maintenance frequency. Low per‑pole power loss (4.6 W) improves panel efficiency, contributing to lower operating costs over the device’s life in automation applications.