ABB 2TFH100596R1001 Moulded Case Circuit Breaker - IEC60947-2
Part Number: 2TFH100596R1001
Quick Summary
ABB 2TFH100596R1001 Moulded Case Circuit Breaker protects low-voltage motor and distribution circuits in industrial panels. Engineers often struggle with reliable short-circuit protection while keeping nuisance tripping and downtime to a minimum. It adheres to IEC60947-2 and CE declarations, with RoHS compliance and CMRT reporting, helping meet global supply-chain and environmental requirements. By leveraging the SACE Tmax XT heritage and a plug-in 4P design, it delivers robust protection, faster installation, and consistent field performance, translating into shorter commissioning times and lower lifecycle costs for panel builders and OEMs.
Product Information
Extended Description
2TFH100596R1001 ABB: XT1S160 TMD80/800 PMP 4P
Environmental Product Declaration - EPD
NoDecNee
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Environmental Information
Breakers - Packaging disposal information
Customs Tariff Number
85362000
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Version
P
Current Type
AC/DC
Electrical Durability
8000 cycle | 120 cycles per hour
Mechanical Durability
25000 cycle | 240 cycles per hour
Number of Poles
4P
Power Loss
at Rated Operating Conditions per Pole 7.2 W
Rated Current (In)
80 A
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Insulation Voltage (Ui)
800 V
Rated Operational Voltage
690 V AC | 500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 63.75 kA | (230 V AC) 63.75 kA | (240 V AC) 63.75 kA | (380 V AC) 50 kA | (415 V AC) 37.5 kA | (440 V AC) 25 kA | (500 V AC) 18 kA | (525 V AC) 17.5 kA | (690 V AC) 5 kA | (250 V DC) 2 Poles in Series 50 kA | (500 V DC) 3 Poles in Series 50 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(220 V AC) 85 kA | (230 V AC) 85 kA | (240 V AC) 85 kA | (380 V AC) 50 kA | (415 V AC) 50 kA | (440 V AC) 50 kA | (500 V AC) 36 kA | (525 V AC) 35 kA | (690 V AC) 8 kA | (250 V DC) 2 Poles in Series 50 kA | (500 V DC) 3 Poles in Series 50 kA
Rated Uninterrupted Current (Iu)
160 A
Release
TMD
Release Type
TM
Remarks
ATLAS
Short-Circuit Performance Level
S
Standards
IEC60947-2 | GB/T 14028.2
Sub-type
XT1
Terminal Connection Type
Plug-In Circuit-Breakers
Data Sheet, Technical Information
SACE Tmax XT IEC Low voltage molded case circuit-breakers Catalog | SACE Tmax XT IEC TECHNICAL CHARACTERISTICS Low voltage molded case circuit-breakers
Declaration of Conformity - CE
EC Declaration of Conformity Tmax XT1
Instructions and Manuals
Installation instructions XT1
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
Four-pole, 80 A nominal current, and 690 V AC / 500 V DC operation enable comprehensive protection for three-phase machines and feeders. This configuration ensures balanced fault handling, reducing unequal phase currents and nuisance trips, which translates to higher line availability and lower maintenance costs in manufacturing lines. The plug-in terminal connection type supports quick, error-free installation and simplifies future upgrades in evolving control panels. In critical applications, Ics of 63.75 kA and Icu up to 85 kA provide strong fault-clearing capability across standard distribution voltages, improving safety margins for motors and feeders in presses and conveyor systems. The XT1 release (TMD/TM) aligns with the Tmax XT family, offering predictable protection curves and straightforward replacement in legacy panels. Power loss of 7.2 W per pole contributes to cooler operation and reduced overheating risk in dense panel racks. Compliance with RoHS, CMRT, and WEEE requirements supports responsible procurement and regulatory alignment, while a long mechanical and electrical life supports low total cost of ownership in continuous-run environments.
Get a Quick Quote for a ABB 2TFH100596R1001
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 2TFH100596R1001?
Enquire Now
FAQs
This unit uses plug-in terminals and a four-pole design, making it straightforward to retrofit in ABB Tmax XT compatible panels. Verify panel busbar spacing and terminal torque per the XT1 installation instructions, and ensure the mounting footprint aligns with standard 4P MCCB enclosures to avoid rework during commissioning.
Critical ratings include rated current In of 80 A, rated operational voltage 690 V AC / 500 V DC, Ui of 800 V, Uimp of 8 kV, and breaking capacities Ics up to 63.75 kA and Icu up to 85 kA across selected voltages. These figures inform fault protection selectivity, coordination with downstream devices, and safe isolation during faults.
Yes. With 4P configuration, high Ics/Icu values, and a robust TMD/TM release, it provides reliable motor protection and fast fault clearance. The device supports comprehensive coordination with standard MCCB layouts, minimizing downtime during motor faults and ensuring safer, quicker restarts after protection events.
The unit aligns with IEC60947-2 and GB/T 14028.2, and ships with a CE Declaration of Conformity. RoHS compliance and CMRT reporting are included, helping meet global environmental requirements and supply-chain transparency for regulated industries.
Electrical durability is rated at 8000 cycles and mechanical durability at 25000 cycles, supporting long service life in continuous operations. This translates to lower maintenance intervals and reduced spare parts inventory, delivering a favorable total cost of ownership for OEMs and maintenance teams.