ABB 2TFH100702R1001 Moulded Case Circuit Breaker - IEC60947-2
Part Number: 2TFH100702R1001
Quick Summary
Moulded Case Circuit Breaker ABB 2TFH100702R1001 provides precise overcurrent protection for low-voltage power distributions. In industrial environments, nuisance trips and unplanned downtime undermine productivity, especially in motor feeders and automation panels. This device is designed to meet IEC60947-2 standards while delivering CE declarations, RoHS compliance, and CMRT reporting for regulatory readiness. Built for the ABB SACE Tmax XT family, it supports plug-in installation and compact panel design, delivering reliability, predictable performance, and lifecycle cost savings for panel builders and OEMs.
Product Information
Extended Description
2TFH100702R1001 ABB: XT2H160 TMA50/500 PMP 4P
Environmental Product Declaration - EPD
NoDecNee
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Environmental Information
Breakers - Packaging disposal information
Customs Tariff Number
85362000
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Version
P
Current Type
AC/DC
Electrical Durability
8000 cycle | 120 cycles per hour
Mechanical Durability
25000 cycle | 240 cycles per hour
Number of Poles
4P
Power Loss
at Rated Operating Conditions per Pole 4.7 W
Rated Current (In)
50 A
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Insulation Voltage (Ui)
1000 V
Rated Operational Voltage
690 V AC | 500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 100 kA | (230 V AC) 100 kA | (240 V AC) 100 kA | (380 V AC) 70 kA | (415 V AC) 70 kA | (440 V AC) 65 kA | (500 V AC) 50 kA | (525 V AC) 30 kA | (690 V AC) 15 kA | (250 V DC) 2 Poles in Series 70 kA | (500 V DC) 3 Poles in Series 70 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(220 V AC) 100 kA | (230 V AC) 100 kA | (240 V AC) 100 kA | (380 V AC) 70 kA | (415 V AC) 70 kA | (440 V AC) 65 kA | (500 V AC) 50 kA | (525 V AC) 30 kA | (690 V AC) 15 kA | (250 V DC) 2 Poles in Series 70 kA | (500 V DC) 3 Poles in Series 70 kA
Rated Uninterrupted Current (Iu)
160 A
Release
TMA
Release Type
TM
Remarks
ATLAS
Short-Circuit Performance Level
H
Standards
IEC60947-2 | GB/T 14028.2
Sub-type
XT2
Terminal Connection Type
Plug-In Circuit-Breakers
Data Sheet, Technical Information
SACE Tmax XT IEC Low voltage molded case circuit-breakers Catalog | SACE Tmax XT IEC TECHNICAL CHARACTERISTICS Low voltage molded case circuit-breakers
Declaration of Conformity - CE
EC Declaration of Conformity Tmax XT2
Instructions and Manuals
Installation Instructions XT2
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
Feature: 4P plug-in design with rated current of 50 A and rated operational voltage up to 690 V AC / 500 V DC. Business Impact: Enables straightforward, fast installation in standard low-voltage panels with minimal wiring complexity, reducing commissioning time and risk of miswiring. Application: Suitable for main and feeder protection in industrial automation where space and reliability matter. Feature: High short‑circuit capability (Ics up to 100 kA at several voltages) and rated ultimate short‑circuit capacity (Icu) also up to 100 kA. Business Impact: Delivers robust fault protection, minimizing arc energy and equipment damage during faults. Application: Motor control centers, distribution boards, and high‑interrupting applications in manufacturing. Feature: Electrical and mechanical durability rated for up to 8000 electrical cycles and 25000 mechanical cycles. Business Impact: Extends service life, reduces maintenance frequency, and lowers lifecycle operating costs. Application: Continuous operation environments with frequent switching, such as conveyors and press lines. Feature: Compliance stack including IEC60947-2, CE Declaration, RoHS status, and CMRT. Business Impact: Simplifies regulatory clearance, supplier audits, and sustainability reporting. Application: OEM panel builds and end users requiring traceable compliance. Feature: Product naming and releases (XT2, TM/TMA variants) with plug‑in polarity and 4P configuration. Business Impact: Supports scalable panel architectures and easy replacement within the Tmax XT ecosystem. Application: Refurbishment projects and upgrades in established control architectures.
Get a Quick Quote for a ABB 2TFH100702R1001
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 2TFH100702R1001?
Enquire Now
FAQs
Yes. The 2TFH100702R1001 is a plug‑in, 4P molded case circuit breaker designed for standard low‑voltage panels. It integrates with typical busbar spacings used in SACE Tmax XT systems, supports straightforward wiring, and can be swapped without extensive panel rework when matched to the 50 A rating and 690 V AC / 500 V DC operating range.
The device provides a service short‑circuit current (Ics) up to 100 kA across multiple voltages (including 220–240 V AC and 380–440 V AC). Icu (ultimate short‑circuit capacity) is similarly rated up to 100 kA for relevant configurations. These ratings enable robust protection for motor loads, feeders, and distribution circuits with high fault energy.
Ideal for industrial automation, panel builders, and OEMs, the 2TFH100702R1001 suits motor control centers, distribution boards, and automation panels requiring reliable overcurrent protection, compact 4P form factor, and compatibility with Tmax XT devices. It supports both motor drives and line protection in manufacturing, process automation, and packaging facilities.
It complies with IEC 60947‑2 for low‑voltage MCCBs, and carries a CE Declaration of Conformity. RoHS status is documented, CMRT reporting is available, and WEEE categorization applies, supporting regulatory audits and sustainability reporting for global deployment.
With electrical durability rated at 8000 cycles and mechanical durability at 25000 cycles, the XT series reduces maintenance frequency and downtime. The plug‑in design simplifies replacement, improving mean time to repair (MTTR) and overall total cost of ownership (TCO) for control panels and critical automation lines.