ABB 2TFH100703R1001 Moulded Case Circuit Breaker - XT2 IEC60947-2
Part Number: 2TFH100703R1001
Quick Summary
ABB XT2 Moulded Case Circuit Breaker provides reliable overcurrent protection for industrial panels and power distribution in automation environments. Engineers often struggle with nuisance trips, long downtime, and complex regulatory compliance when selecting protective devices. This 4-pole XT2 MCCB meets IEC 60947-2, CE conformity via EC Declaration of Conformity, RoHS and REACH declarations, and CMRT, ensuring regulatory readiness. Designed for plug-in installation, it offers a robust 63 A rating and a wide operating range up to 690 V AC / 500 V DC, delivering both safety and steady uptime while reducing maintenance costs and improving panel footprint efficiency.
Product Information
Extended Description
2TFH100703R1001 ABB: XT2H160 TMA63/630 PMP 4P
Environmental Product Declaration - EPD
NoDecNee
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Environmental Information
Breakers - Packaging disposal information
Customs Tariff Number
85362000
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Version
P
Current Type
AC/DC
Electrical Durability
8000 cycle | 120 cycles per hour
Mechanical Durability
25000 cycle | 240 cycles per hour
Number of Poles
4P
Power Loss
at Rated Operating Conditions per Pole 5.7 W
Rated Current (In)
63 A
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Insulation Voltage (Ui)
1000 V
Rated Operational Voltage
690 V AC | 500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 100 kA | (230 V AC) 100 kA | (240 V AC) 100 kA | (380 V AC) 70 kA | (415 V AC) 70 kA | (440 V AC) 65 kA | (500 V AC) 50 kA | (525 V AC) 30 kA | (690 V AC) 15 kA | (250 V DC) 2 Poles in Series 70 kA | (500 V DC) 3 Poles in Series 70 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(220 V AC) 100 kA | (230 V AC) 100 kA | (240 V AC) 100 kA | (380 V AC) 70 kA | (415 V AC) 70 kA | (440 V AC) 65 kA | (500 V AC) 50 kA | (525 V AC) 30 kA | (690 V AC) 15 kA | (250 V DC) 2 Poles in Series 70 kA | (500 V DC) 3 Poles in Series 70 kA
Rated Uninterrupted Current (Iu)
160 A
Release
TMA
Release Type
TM
Remarks
ATLAS
Short-Circuit Performance Level
H
Standards
IEC60947-2 | GB/T 14028.2
Sub-type
XT2
Terminal Connection Type
Plug-In Circuit-Breakers
Data Sheet, Technical Information
SACE Tmax XT IEC Low voltage molded case circuit-breakers Catalog | SACE Tmax XT IEC TECHNICAL CHARACTERISTICS Low voltage molded case circuit-breakers
Declaration of Conformity - CE
EC Declaration of Conformity Tmax XT2
Instructions and Manuals
Installation Instructions XT2
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
Feature → Business Impact → Application: 4P Plug-In design enables quick installation and easy field replacement, reducing commissioning time and minimizing downtime in control cabinets and switchgear assemblies. This directly lowers labor costs and increases line uptime during expansion or relocation projects. Feature → 63 A rated current with 690 V AC / 500 V DC operating voltage provides scalable protection for medium-load machines, conveyors, and motor control centers, helping ensure safe operation and preventing costly motor damage. Feature → 8 kV rated impulse withstand voltage and 100 kA short-circuit capability (Ics) at relevant voltages deliver superior fault isolation, supporting safe crew operation and protecting critical equipment in high-energy environments. Feature → 4P configuration with 5.7 W per pole power loss maintains efficiency in dense panels, reducing heat buildup and cooling requirements, which translates to lower energy and cooling costs over the lifecycle. Feature → Release options TMA/TM with XT2 sub-type offer selective coordination and fast actuation, enabling precise protection curves for varied machine loads and helping achieve regulatory and industry-standard compliance. Feature → RoHS/REACH declarations and CMRT inclusion provide compliance assurance for supply chains and end products, easing procurement and reducing sustainability risk for corporate ESG reporting. Feature → Compliance with IEC60947-2 and CE declarations aligns with global industry standards, supporting cross-border deployments in manufacturing and process industries. Feature → Environmental and packaging data, including packaging disposal information, supports responsible end-of-life planning and waste reduction goals for industrial facilities. Application suitability spans control panels, motor control centers, machine builders, and industrial automation racks, where predictable protection and easy maintenance translate to measurable ROI.
Get a Quick Quote for a ABB 2TFH100703R1001
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 2TFH100703R1001?
Enquire Now
FAQs
Yes. This 4-pole plug-in circuit breaker is designed for plug-in installation in typical low-voltage switchgear and control panel assemblies, enabling fast replacement and straightforward wiring with standard terminal connection types to minimize commissioning time and wiring errors.
Key ratings include rated current In of 63 A, rated insulation voltage Ui of 1000 V, rated operational voltage up to 690 V AC / 500 V DC, rated impulse withstand voltage Uimp of 8 kV, and short-circuit breaking capacities Ics/Icu varying by voltage up to 100 kA and 70 kA respectively, ensuring strong fault protection across applications.
It complies with IEC 60947-2 and GB/T 14028.2, carries CE conformity via EC Declaration of Conformity, and aligns with RoHS and REACH directives, plus CMRT for conflict minerals reporting and WEEE packaging/disposal guidance.
Electrical durability up to 8000 cycles and mechanical durability up to 25000 cycles, with 5.7 W power loss per pole at rated conditions, translate to predictable performance, reduced thermal stress, and lower cooling costs over the product lifecycle.
Ideal for industrial automation panels, motor control centers, and power distribution in manufacturing lines, machine-build projects, and process facilities where reliable protective switching, fast fault isolation, and regulatory compliance are critical for uptime and safety.