ABB 2TFH102021R1001 MCCB - Icu 100 kA
Part Number: 2TFH102021R1001
Quick Summary
ABB 2TFH102021R1001 MCCB is a high‑reliability molded case circuit breaker for electrical distribution panels. Engineers face downtime, miscoordination, and compliance challenges when protecting 690 V AC networks. Certified to IEC 60947-2 with CE conformity, RoHS and REACH declarations, this device supports global sourcing and risk reduction. Its 3P 63 A rating, 690 V operating voltage, and withstand capabilities keep protective schemes consistent under load while offering predictable tripping performance. Designed for withdrawable circuit-breaker assemblies, XT2 family features enable modular panel builds. Together with clear labeling, lifecycle data, and minimal maintenance needs, it helps reduce total cost of ownership and improves service continuity across industrial facilities. Designed for panel builders and maintenance teams, it integrates with SACE Tmax XT installation instructions and provides lifecycle data. Its low power loss of 2.1 W per pole reduces heat in compact switchgear, supporting energy efficiency and reliability.
Product Information
Extended Description
2TFH102021R1001 ABB: XT2H160 Ekip LSI R63 WMP 3P
Environmental Product Declaration - EPD
NoDecNee
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Environmental Information
Breakers - Packaging disposal information
Customs Tariff Number
85362000
Product Net Width
90.0 mm
Product Net Height
130 mm
Product Net Depth / Length
82.5 mm
Product Net Weight
3.32 kg
Package Level 1 Width
287 mm
Package Level 1 Height
230 mm
Package Level 1 Depth / Length
245 mm
Package Level 1 Gross Weight
3.42 kg
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Version
W
Current Type
AC
Electrical Durability
8000 cycle | 120 cycles per hour
Mechanical Durability
25000 cycle | 240 cycles per hour
Number of Poles
3P
Power Loss
at Rated Operating Conditions per Pole 2.1 W
Rated Current (In)
63 A
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Insulation Voltage (Ui)
1000 V
Rated Operational Voltage
690 V AC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 100 kA | (230 V AC) 100 kA | (240 V AC) 100 kA | (380 V AC) 70 kA | (415 V AC) 70 kA | (440 V AC) 65 kA | (500 V AC) 50 kA | (525 V AC) 30 kA | (690 V AC) 15 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(220 V AC) 100 kA | (230 V AC) 100 kA | (240 V AC) 100 kA | (380 V AC) 70 kA | (415 V AC) 70 kA | (440 V AC) 65 kA | (500 V AC) 50 kA | (525 V AC) 30 kA | (690 V AC) 15 kA
Rated Uninterrupted Current (Iu)
160 A
Release
Ekip LSI
Release Type
EL
Remarks
ATLAS
Short-Circuit Performance Level
H
Standards
IEC60947-2 | GB/T 14028.2
Sub-type
XT2
Terminal Connection Type
Withdrawable Circuit-Breakers
Data Sheet, Technical Information
SACE Tmax XT IEC Low voltage molded case circuit-breakers Catalog | SACE Tmax XT IEC TECHNICAL CHARACTERISTICS Low voltage molded case circuit-breakers
Declaration of Conformity - CE
EC Declaration of Conformity Tmax XT2
Instructions and Manuals
Installation Instructions XT2 | Ekip C Dip LSI, Ekip C Dip LSIG and LIG XT2-XT4
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
Feature: 3P 63 A rating and 690 V AC operating voltage → Business Impact: Enables protection for medium‑power distribution with clear headroom for short‑term surges and motor starting in industrial panels. Application: Suitable for 3‑phase feeders in commercial and light‑industrial environments, reducing nuisance trips during normal operation. Feature: Icu up to 100 kA at low voltages and Ics up to 100 kA for 220–240 V ranges → Business Impact: Superior short‑circuit protection with fast, predictable disconnection, reducing arc flash risk and equipment damage. Application: Critical for panel boards servicing motors and conveyors where fault currents spike. Feature: Withdrawable circuit‑breaker terminal connection → Business Impact: Quick replacement, safer maintenance, and easier configuration changes without extensive downtime. Application: Ideal for modular switchgear and retrofits in growing facilities. Feature: Ekip LSI release and XT2 sub‑type → Business Impact: Precise tripping logic with reliable release behavior and compatibility with SACE Tmax XT families, improving coordination and protective hierarchy. Application: Panels requiring harmonized protection across devices and easy upgrade paths. Feature: Power loss 2.1 W per pole; Electrical durability 8000 cycles; Mechanical durability 25000 cycles → Business Impact: Lower operating heat, longer service life, and reduced maintenance costs in demanding production lines. Application: High‑cycle environments such as packaging, filling, and material handling. Feature: RoHS, REACH, CMRT, and EC Declaration of Conformity → Business Impact: Compliance across global markets minimizes regulatory risk and simplifies procurement. Application: Global manufacturing deployments with diverse supplier bases. Feature: Product data and standards alignment with IEC 60947-2 and GB/T 14028.2 → Business Impact: Streamlined engineering documentation and tests for commissioning and regulatory reviews. Application: New installations and modernization projects in electrical distribution. Insight: ABB’s XT2 lineage is engineered for reliable performance in harsh environments; real‑world installations benefit from compatibility with withdrawable configurations and straightforward maintenance planning, delivering a lower total cost of ownership over the lifetime of the equipment.
Get a Quick Quote for a ABB 2TFH102021R1001
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 2TFH102021R1001?
Enquire Now
FAQs
This device uses Withdrawable Circuit-Breaker terminals, which support rapid insertion and removal from panel boards. For best results, follow ABB installation instructions for XT2 products, ensure correct appliance cable torque per terminal, and verify compatibility with the panel’s busbar spacing and clearance. This minimizes contact resistance and ensures reliable tripping during faults.
The 3P 63 A ABB MCCB provides Ics up to 100 kA at 230–240 V and lower Ics values at higher voltages, with Icu up to 100 kA at low voltages. This enables robust protection against phase-to-phase faults and line-to-ground faults, preserving downstream equipment and reducing downtime in fault scenarios.
Yes. The device aligns with IEC 60947-2 standards and carries CE conformity. It also provides RoHS and REACH declarations, along with documentation like EC Declaration of Conformity and CMRT, facilitating regulatory approvals and global sourcing.
The XT2 sub‑type, Ekip LSI release, and 3P configuration offer predictable trip behavior and modular compatibility with withdrawable assemblies. This ensures protection coordination across devices in SACE Tmax XT ecosystems, simplifies lifecycle management, and supports scalable panel builds for growing plants.
Electrical durability is rated at 8000 cycles and mechanical durability at 25000 cycles, with a power loss of 2.1 W per pole. These metrics translate to longer service life, lower heat generation, and reduced maintenance interventions in high‑duty environments such as packaging lines or material handling systems.