ABB 2TFH102065R1001 Moulded Case Circuit Breaker - XT2
Part Number: 2TFH102065R1001
Quick Summary
ABB 2TFH102065R1001 Moulded Case Circuit Breaker protects industrial panels and machines from short circuits. In demanding environments, downtime and unscheduled maintenance erode productivity and margin. This model complies with IEC 60947-2 and CE declarations, and RoHS obligations, while CMRT and packaging information support responsible procurement. Built for the SACE Tmax XT ecosystem and Ekip LSIG control, it delivers reliable protection with streamlined installation and service. For panel builders and maintenance teams, the result is safer operation, faster commissioning, and predictable lifecycle costs.
Product Information
Extended Description
2TFH102065R1001 ABB: XT2H160 Ekip LSIG R100 WMP 4P
Environmental Product Declaration - EPD
NoDecNee
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Environmental Information
Breakers - Packaging disposal information
Customs Tariff Number
85362000
Product Net Width
120.0 mm
Product Net Height
130 mm
Product Net Depth / Length
82.5 mm
Product Net Weight
4.04 kg
Package Level 1 Width
287 mm
Package Level 1 Height
230 mm
Package Level 1 Depth / Length
245 mm
Package Level 1 Gross Weight
4.04 kg
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Version
W
Current Type
AC
Electrical Durability
8000 cycle | 120 cycles per hour
Mechanical Durability
25000 cycle | 240 cycles per hour
Number of Poles
4P
Power Loss
at Rated Operating Conditions per Pole 5.2 W
Rated Current (In)
100 A
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Insulation Voltage (Ui)
1000 V
Rated Operational Voltage
690 V AC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 100 kA | (230 V AC) 100 kA | (240 V AC) 100 kA | (380 V AC) 70 kA | (415 V AC) 70 kA | (440 V AC) 65 kA | (500 V AC) 50 kA | (525 V AC) 30 kA | (690 V AC) 15 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(220 V AC) 100 kA | (230 V AC) 100 kA | (240 V AC) 100 kA | (380 V AC) 70 kA | (415 V AC) 70 kA | (440 V AC) 65 kA | (500 V AC) 50 kA | (525 V AC) 30 kA | (690 V AC) 15 kA
Rated Uninterrupted Current (Iu)
160 A
Release
Ekip LSIG
Release Type
EL
Remarks
ATLAS
Short-Circuit Performance Level
H
Standards
IEC60947-2 | GB/T 14028.2
Sub-type
XT2
Terminal Connection Type
Withdrawable Circuit-Breakers
Data Sheet, Technical Information
SACE Tmax XT IEC Low voltage molded case circuit-breakers Catalog | SACE Tmax XT IEC TECHNICAL CHARACTERISTICS Low voltage molded case circuit-breakers
Declaration of Conformity - CE
EC Declaration of Conformity Tmax XT2
Instructions and Manuals
Installation Instructions XT2 | Ekip C Dip LSI, Ekip C Dip LSIG and LIG XT2-XT4
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
Feature Withdrawable circuit-breaker design enables fast, safe maintenance without complicated wiring or power-downs, reducing downtime and improving changeover times in control panels. Business impact Faster restoration of production lines and lower maintenance labor costs, with a clear workflow for service and replacement. Application Suitable for industrial automation panels, machine builders, and power distribution boards in manufacturing environments. Feature High short-circuit withstand and rated current of 100 A with 690 V AC operating voltage; Ics up to 100 kA depending on voltage, Icu up to 100 kA at common LV ranges. Business impact Enhanced safety margins and reduced risk of cascading faults in harsh electrical settings; Application uses in motor control centers and process lines. Feature Withdrawable terminal connections and 4P configuration simplify installation, wiring checks, and wiring harness routing. Business impact Faster, error-free commissioning and scalable protection for multi-pole machines; Application ideal for modular panel builds. Feature RoHS compliant and CE declared with EPD and CMRT data, supporting corporate sustainability and regulatory audits. Business impact Lower environmental and compliance risk, simplified supplier documentation, and faster approvals during audits; Application supports procurement and engineering handoffs. Feature Dimensions and weight (120 mm width, 130 mm height, 82.5 mm depth; 4.04 kg) provide clear footprint planning for panel layouts. Business impact Accurate space planning and inventory control, reducing over-design and costly panel changes. Application Suited to compact integration in control cabinets seeking robust protection with predictable service cycles.
Get a Quick Quote for a ABB 2TFH102065R1001
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 2TFH102065R1001?
Enquire Now
FAQs
This breaker uses a withdrawable terminal connection and 4P configuration, designed for SACE Tmax XT panels and Ekip LSIG control. It fits standard LV distribution setups and is compatible with ABB installation manuals for XT2 devices, enabling straightforward panel integration and maintenance.
Rated Current is 100 A with Rated Operational Voltage of 690 V AC and Rated Insulation Voltage of 1000 V. It offers rated impulse withstand of 8 kV and short-circuit breaking capacities up to 100 kA (Ics/Icu varies by voltage). Power loss per pole is 5.2 W, contributing to efficient operation.
Yes. The product carries RoHS declarations and CE conformity documentation. Additional compliance data include IEC 60947-2 standards and relevant packaging/disposal information, supporting responsible procurement and regulatory audits.
Ideal for industrial control panels, machine control cabinets, and power distribution boards in automation facilities. Its 4P configuration and rugged XT2 family design suit environments requiring reliable short-circuit protection, predictable maintenance, and easy integration with Ekip LSIG relays.
Electrical durability is rated at about 8000 cycles and mechanical durability at about 25000 cycles, with respective hourly cycle rates. This informs maintenance planning, replacement intervals, and spare-part stocking for sustained panel reliability.