ABB 2TFH102081R1001 Moulded Case Circuit Breaker - Ics 100kA

Manufacturer
ABB
Part number
2TFH102081R1001

Quick Summary

ABB 2TFH102081R1001 is a moulded case circuit breaker designed to protect low‑voltage control panels and motor circuits in industrial environments. Engineers seek devices that deliver reliable protection, minimal nuisance trips, and straightforward maintenance in demanding plants. This XT2 series MCCB carries CE conformity and robust declarations under IEC60947‑2 and GB/T 14028.2, along with REACH, RoHS, and WEEE considerations for compliance. With a 3P configuration, rated current of 8.5 A, and Ics up to 100 kA, it guards both 690 V AC and 500 V DC circuits while enabling fast service with withdrawable mounting for easy maintenance and quick replacements.

Product Information

Extended Description

2TFH102081R1001 ABB: XT2H160 MF8.5/120 WMP 3P
Environmental Product Declaration - EPD
NoDecNee
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Environmental Information
Breakers - Packaging disposal information
Customs Tariff Number
85362000
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Version
W
Current Type
AC/DC
Electrical Durability
8000 cycle | 120 cycles per hour
Mechanical Durability
25000 cycle | 240 cycles per hour
Number of Poles
3P
Rated Current (In)
8.5 A
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Insulation Voltage (Ui)
1000 V
Rated Operational Voltage
690 V AC | 500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 100 kA | (230 V AC) 100 kA | (240 V AC) 100 kA | (380 V AC) 70 kA | (415 V AC) 70 kA | (440 V AC) 65 kA | (500 V AC) 50 kA | (525 V AC) 30 kA | (690 V AC) 15 kA | (250 V DC) 2 Poles in Series 70 kA | (500 V DC) 3 Poles in Series 70 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(220 V AC) 100 kA | (230 V AC) 100 kA | (240 V AC) 100 kA | (380 V AC) 70 kA | (415 V AC) 70 kA | (440 V AC) 65 kA | (500 V AC) 50 kA | (525 V AC) 30 kA | (690 V AC) 15 kA | (250 V DC) 2 Poles in Series 70 kA | (500 V DC) 3 Poles in Series 70 kA
Rated Uninterrupted Current (Iu)
160 A
Release
MF
Release Type
M
Remarks
ATLAS
Short-Circuit Performance Level
H
Standards
IEC60947-2 | GB/T 14028.2
Sub-type
XT2
Terminal Connection Type
Withdrawable Circuit-Breakers
Data Sheet, Technical Information
SACE Tmax XT IEC Low voltage molded case circuit-breakers Catalog | SACE Tmax XT IEC TECHNICAL CHARACTERISTICS Low voltage molded case circuit-breakers
Declaration of Conformity - CE
EC Declaration of Conformity Tmax XT2
Instructions and Manuals
Installation Instructions XT2
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
Feature → Business Impact → Application: The 3P design with an 8.5 A rating protects small to medium loads in control cabinets, reducing nuisance trips and unplanned downtime in manufacturing lines. This translates to improved line uptime and predictable maintenance windows for panel builders and electricians when wiring motor feeders or distribution panels. Feature → Business Impact → Application: Ics up to 100 kA at common AC voltages delivers robust short‑circuit protection, enabling fast fault isolation and equipment safety in high‑energy environments such as presses and conveyors. This is critical for plant safety and reducing collateral damage in event of a fault. Feature → Business Impact → Application: Uimp 8 kV and Ui 1000 V provide margin for surge and insulation-stress scenarios, supporting safer commissioning and longer insulation life across diverse control circuits. Feature → Business Impact → Application: Withdrawable circuit‑breaker mounting simplifies maintenance and replacements in live panels, minimizing downtime and facilitating quick swaps during routine service in control rooms and switchgear bays. Feature → Business Impact → Application: Long mechanical and electrical endurance (25000 mechanical cycles, 8000 electrical cycles) lowers maintenance costs and extends service intervals in continuous production lines, particularly for automation cabinets and motor control centers. Feature → Business Impact → Application: Regulatory compliance with CE, RoHS, REACH, and GB/T 14028.2 reduces risk in regulated markets and supports traceability for audits, helping procurement teams meet supplier requirements while maintaining project timelines.

Get a Quick Quote for a ABB 2TFH102081R1001

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 2TFH102081R1001? Enquire Now

FAQs

This MCCB is designed as a 3P withdrawable unit within the SACE Tmax XT family, enabling straightforward mounting in XT panels and easy hot-swap maintenance without full panel disassembly.
Ics is rated up to 100 kA for 220–240 V AC, with 70 kA available at 380–440 V AC, 50 kA at 500 V AC, 30 kA at 525 V AC, and 15 kA at 690 V AC. For DC, 70 kA is available in 250 V and 500 V configurations in series‑connected poles.
Yes. The device supports rated operational voltage up to 690 V AC and 500 V DC, making it suitable for mixed-voltage control circuits found in modern automation and power distribution systems.
The product conforms to IEC60947-2 with GB/T 14028.2, and carries CE declarations, RoHS and REACH information, along with WEEE categorization for responsible disposal.
With withdrawable mounting and endurance ratings of up to 8000 electrical cycles and 25000 mechanical cycles, this MCCB supports easier maintenance, reduced downtime, and longer service life in demanding automation environments.