ABB 2TFH102090R1001 Moulded Case Circuit Breaker - Icu 100 kA
Part Number: 2TFH102090R1001
Quick Summary
ABB 2TFH102090R1001 Moulded Case Circuit Breaker protects low‑voltage power distribution in industrial automation systems. End users often struggle with panel downtime and unreliable fault protection, which can stall production and drive maintenance costs. The device is designed to meet IEC60947-2 standards and CE declarations, with RoHS and REACH compliance, aligning with global safety and sustainability requirements. With a 3‑pole XT2 design, 160 A rating and 690 V AC / 500 V DC capability, it supports robust protection and compatible integration into standard control panels, modular cabinets, and SACE Tmax XT lineups for scalable automation. Engineers appreciate the withdrawable terminal connection for quick replacements, while the modest 19 W per pole power loss helps reduce cooling load in continuous operation.
Product Information
Extended Description
2TFH102090R1001 ABB: XT2H160 TMA160/1600 WMP 3P
Environmental Product Declaration - EPD
NoDecNee
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Environmental Information
Breakers - Packaging disposal information
Customs Tariff Number
85362000
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Version
W
Current Type
AC/DC
Electrical Durability
8000 cycle | 120 cycles per hour
Mechanical Durability
25000 cycle | 240 cycles per hour
Number of Poles
3P
Power Loss
at Rated Operating Conditions per Pole 19.0 W
Rated Current (In)
160 A
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Insulation Voltage (Ui)
1000 V
Rated Operational Voltage
690 V AC | 500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 100 kA | (230 V AC) 100 kA | (240 V AC) 100 kA | (380 V AC) 70 kA | (415 V AC) 70 kA | (440 V AC) 65 kA | (500 V AC) 50 kA | (525 V AC) 30 kA | (690 V AC) 15 kA | (250 V DC) 2 Poles in Series 70 kA | (500 V DC) 3 Poles in Series 70 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(220 V AC) 100 kA | (230 V AC) 100 kA | (240 V AC) 100 kA | (380 V AC) 70 kA | (415 V AC) 70 kA | (440 V AC) 65 kA | (500 V AC) 50 kA | (525 V AC) 30 kA | (690 V AC) 15 kA | (250 V DC) 2 Poles in Series 70 kA | (500 V DC) 3 Poles in Series 70 kA
Rated Uninterrupted Current (Iu)
160 A
Release
TMA
Release Type
TM
Remarks
ATLAS
Short-Circuit Performance Level
H
Standards
IEC60947-2 | GB/T 14028.2
Sub-type
XT2
Terminal Connection Type
Withdrawable Circuit-Breakers
Data Sheet, Technical Information
SACE Tmax XT IEC Low voltage molded case circuit-breakers Catalog | SACE Tmax XT IEC TECHNICAL CHARACTERISTICS Low voltage molded case circuit-breakers
Declaration of Conformity - CE
EC Declaration of Conformity Tmax XT2
Instructions and Manuals
Installation Instructions XT2
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
Feature: Three‑pole XT2 design supports reliable distribution in 160 A panels. Benefit: Improves fault containment and minimizes nuisance trips, translating to higher line availability in machine control and packaging lines. Application: Industrial automation panels and distribution boards. Feature: Rated operational voltage of 690 VAC / 500 V DC with Ui of 1000 V. Benefit: Enhances insulation margin and safety across mixed AC/DC networks, reducing the risk of insulation failure in harsh plant environments. Application: LV distribution in mixed-voltage ecosystems. Feature: Short‑circuit and impulse withstand ratings up to 8 kV and Ics up to 100 kA depending on voltage. Benefit: Strong fault tolerance that protects downstream equipment and minimizes arc flash exposure, lowering total cost of ownership. Application: Heavy‑duty motor drives and press control circuits. Feature: Withdrawable terminal connection for easy maintenance. Benefit: Simplifies replacement and upgrade of panels with minimal downtime, improving serviceability in critical lines. Application: Routine maintenance and panel modernization. Feature: Electrical durability rated at 8000 cycles and mechanical durability at 25000 cycles. Benefit: Long service life with predictable performance, reducing spare parts and service interventions. Application: High‑cycle automation and continuous production lines. Feature: Power loss of 19 W per pole. Benefit: Lower heat generation in switchgear, contributing to cooler enclosures and reduced cooling costs. Application: Compact control cabinets and energy‑aware facilities. Feature: Compliance with CE, RoHS, REACH, and CMRT declarations. Benefit: Streamlined regulatory compliance and responsible sourcing for global deployments. Application: Global manufacturing environments with stringent sustainability goals.
Get a Quick Quote for a ABB 2TFH102090R1001
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 2TFH102090R1001?
Enquire Now
FAQs
The 2TFH102090R1001 uses withdrawable terminals and three poles, making it ideal for standard low‑voltage distribution panels and machine control panels. It integrates easily with Tmax XT modular systems and is compatible with 690 VAC and 500 V DC networks, facilitating straightforward panel upgrades and maintenance.
This unit provides Ics up to 100 kA at typical voltages and Icu up to 70–100 kA depending on the connected voltage. It features an impulse withstand voltage of 8 kV and a rated insulation voltage of 1000 V, suitable for robust protection in diverse LV applications.
Yes. It includes a CE Declaration of Conformity for Tmax XT2, RoHS compliance per EU directives, and REACH declarations. Additional CMRT documentation is available, supporting sustainable sourcing and regulatory compliance for global deployments.
The device offers electrical durability of up to 8000 cycles and mechanical durability up to 25000 cycles, with 3P configuration and withdrawable terminals. This makes it well suited for high‑demand automation lines and frequent maintenance cycles.
With a power loss of 19 W per pole, the unit helps reduce enclosure heat and cooling requirements. The withdrawable design speeds maintenance, and the device’s compatibility with Tmax XT ecosystems supports modular upgrades and faster fault isolation, boosting overall uptime.