ABB 2TFH102104R1001 Moulded Case Circuit Breaker - Tmax XT

Part Number: 2TFH102104R1001
Manufacturer
ABB
Part number
2TFH102104R1001

Quick Summary

ABB 2TFH102104R1001 is a 3-pole moulded case circuit breaker for safe, reliable power distribution in industrial panels. Engineers often struggle with downtime, selectivity, and compliance when upgrading legacy protection schemes, risking outages and costly rewiring. This device carries CE conformity, IEC 60947-2 and GB/T 14028.2 standards, plus RoHS declarations to support sustainability and regulatory alignment. Designed for modular protection within the SACE Tmax XT family, it delivers a 25 A rated current and a 690 V AC / 500 V DC operational voltage, simplifying parts sourcing and maintenance planning for panel builders and end users. The combination of compact footprint, withdrawable connections, and clear documentation translates to faster installation and lower lifecycle costs.

Product Information

Extended Description

2TFH102104R1001 ABB: XT2H160 TMD25/300 WMP 3P
Environmental Product Declaration - EPD
NoDecNee
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Environmental Information
Breakers - Packaging disposal information
Customs Tariff Number
85362000
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Version
W
Current Type
AC/DC
Electrical Durability
8000 cycle | 120 cycles per hour
Mechanical Durability
25000 cycle | 240 cycles per hour
Number of Poles
3P
Power Loss
at Rated Operating Conditions per Pole 2.5 W
Rated Current (In)
25 A
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Insulation Voltage (Ui)
1000 V
Rated Operational Voltage
690 V AC | 500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 100 kA | (230 V AC) 100 kA | (240 V AC) 100 kA | (380 V AC) 70 kA | (415 V AC) 70 kA | (440 V AC) 65 kA | (500 V AC) 50 kA | (525 V AC) 30 kA | (690 V AC) 15 kA | (250 V DC) 2 Poles in Series 70 kA | (500 V DC) 3 Poles in Series 70 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(220 V AC) 100 kA | (230 V AC) 100 kA | (240 V AC) 100 kA | (380 V AC) 70 kA | (415 V AC) 70 kA | (440 V AC) 65 kA | (500 V AC) 50 kA | (525 V AC) 30 kA | (690 V AC) 15 kA | (250 V DC) 2 Poles in Series 70 kA | (500 V DC) 3 Poles in Series 70 kA
Rated Uninterrupted Current (Iu)
160 A
Release
TMD
Release Type
TM
Remarks
ATLAS
Short-Circuit Performance Level
H
Standards
IEC60947-2 | GB/T 14028.2
Sub-type
XT2
Terminal Connection Type
Withdrawable Circuit-Breakers
Data Sheet, Technical Information
SACE Tmax XT IEC Low voltage molded case circuit-breakers Catalog | SACE Tmax XT IEC TECHNICAL CHARACTERISTICS Low voltage molded case circuit-breakers
Declaration of Conformity - CE
EC Declaration of Conformity Tmax XT2
Instructions and Manuals
Installation Instructions XT2
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
Feature: 3P design with 25 A current rating and AC/DC compatibility provides protection across mixed-voltage circuits. Business Impact: enables safer start-ups, minimizes nuisance trips, and reduces the need for multiple devices in a shared enclosure. Application: ideal for panel feeders and machine control circuits in manufacturing lines. Feature: Rated Insulation Voltage 1000 V and Rated Operational Voltage 690 V AC / 500 V DC offer higher insulation margin and wider applicability in mixed-voltage systems. Business Impact: reduces engineering changes during future upgrades and simplifies future expansion. Application: panel designs that require flexibility for future changes. Feature: High fault current ratings (Ics/Icu up to 100 kA depending on voltage) deliver reliable coordination and faster fault interruption. Business Impact: protects costly equipment and maintains operator safety. Application: power distribution nodes in manufacturing lines and data centers. Feature: TMD/TM release with XT2 sub-type improves selectivity and rapid disconnection. Business Impact: minimizes outages on neighboring circuits and shortens downtime. Application: coordinated protection in SACE Tmax XT installations. Feature: Power loss of 2.5 W per pole reduces heat generation and cooling load. Business Impact: lowers energy usage and extends component lifespan. Application: continuous operation in warm industrial environments. Feature: Withdrawable terminal connections simplify maintenance and promote safer servicing. Business Impact: enables faster parts replacement and reduced maintenance window. Application: serviceable switchgear and modular panel assemblies. Feature: Comprehensive compliance documentation (CE declaration, RoHS status, CMRT). Business Impact: accelerates QA and procurement cycles. Application: regulatory-ready deployments in new builds and upgrades.

Get a Quick Quote for a ABB 2TFH102104R1001

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 2TFH102104R1001? Enquire Now

FAQs

This 3P moulded case circuit breaker uses withdrawable connections, aligning with standard switchgear layouts. It fits common 690 V AC and 500 V DC systems and supports panel-level protection with compatible busbar spacing. When replacing legacy devices, verify space for the withdrawable mechanism and ensure mounting width aligns with your enclosure specifications.
The device offers high fault current protection with Ics up to 100 kA at multiple voltages and Icu up to 70–100 kA, depending on voltage. It is rated for 25 A and provides 8 kV rated impulse withstand. These ratings enable reliable coordination in power feeders and protect downstream equipment during faults.
Yes, the ABB 2TFH102104R1001 is CE conformant. It adheres to IEC 60947-2 and GB/T 14028.2 standards, and ABB provides RoHS declarations. These certifications support regulatory compliance in global manufacturing environments and facilitate smoother customer approvals and audits.
Withdrawable connections allow quick replacement and reduced maintenance downtime. The 3P configuration with a compact footprint simplifies panel layouts, while the 2.5 W per pole power loss reduces thermal load. Together, these features lower energy costs and shorten service cycles in ongoing operations.
This unit is ideal for industrial control panels and machine-fed distributions requiring reliable protection with easy maintenance. Its XT2 lineage, 25 A rating, and 690 V AC / 500 V DC capability make it well-suited for motor feeders, packaging lines, and process automation environments where uptime and compliance are critical.