ABB 2TFN000097A1001 Moulded Case Circuit Breaker - IEC60947-2

Part Number: 2TFN000097A1001
Manufacturer
ABB
Part number
2TFN000097A1001

Quick Summary

ABB 2TFN000097A1001 is a 3-pole molded case circuit breaker for protecting 690 V AC power distribution. In modern plants, nuisance trips and difficult diagnostics erode uptime and increase maintenance costs. It meets IEC 60947-2, CE conformity, and RoHS/REACH declarations to support global compliance. Ideal for site protection and Ekip Touch LSI trip-unit integration, it reduces maintenance time and enhances system reliability.

Product Information

Extended Description

2TFN000097A1001 ABB: XT2H 160 Ekip Touch LSI In=160A 3p F F
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions
Disassembly instructions Tmax XT XT2 ELT
Environmental Product Declaration - EPD
EPD Tmax XT XT2 ELT (CN)
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 55.7 %
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
SCIP
e5161877-809a-4803-bf8e-5a55dc240cbe China (CN)
Simplified SCIP
9df4b0f7-bec0-46b5-8806-6f6565930d92 France (FR) | 76588c05-c814-4a5d-990e-3e3252febfcd Spain (ES) | 3cab2972-0cf8-4a35-b63a-774b3f1d8a86 Greece (GR) | e7dc711c-8bd3-468c-a89a-150ddbdfea1f Germany (DE) | 67d44ea7-4f40-46a4-94d3-cd129758267a Poland (PL) | efbca911-fe28-4007-8f24-1ab413b2bc55 Netherlands (NL) | 85a5a6df-f7c9-469b-91a3-452d0bb52a46 Poland (PL) | 71360a75-9e4f-417d-b7a6-ac396ec377a0 Denmark (DK) | 81e76138-fccb-4daa-b368-12e251f9c0ad Hungary (HU) | 15c2b5cb-77ed-4238-a68f-35aaa009397d Norway (NO) | 634a3a90-52f7-42a3-805c-771e87c79851 Estonia (EE) | a4bfb16e-700d-4a9f-a44d-84b517395a80 Hungary (HU) | 39d2df7f-9f06-4582-a684-7f77b1261a05 Finland (FI) | 63e6ec8a-c061-423e-802b-6fcab4b8c37b Belgium (BE) | e6563579-5066-4bd6-94e8-dc633971bfd8 Bulgaria (BG) | 26bcda64-7d72-4a16-bb3d-a798063189b3 Belgium (BE) | e480cf20-e9bf-4263-9518-507900a390eb Croatia (HR) | f53f02f3-4e9b-409c-9e69-6a6689b1061a Germany (DE) | de33fc1a-2742-4dfd-8b0f-c395ad1e33b9 Czech Republic (CZ) | face1143-5180-437f-8017-302473dcf2fa Sweden (SE) | d014e857-866d-49d0-ab4f-1b34d7a845b0 Germany (DE) | 6f56aa6d-00b9-49f7-bab7-2278bd9364b1 Poland (PL) | 28c354c2-435d-44b7-9633-891dc73c326b France (FR) | 994de04c-87d3-44bb-b11c-e7f1a4f578bc Sweden (SE) | b2beee9c-397f-4489-99be-a7399826acd7 Germany (DE) | 6016bacb-5df3-4db1-878d-c4286dbaa530 Germany (DE) | fc7c6f80-ff8d-4040-9614-82d4a9b1fe43 Portugal (PT)
Environmental Information
Breakers - Packaging disposal information
Customs Tariff Number
85362000
Product Net Width
90.0 mm
Product Net Height
130 mm
Product Net Depth / Length
82.5 mm
Product Net Weight
1.2 kg
Package Level 1 Width
150 mm
Package Level 1 Height
214 mm
Package Level 1 Depth / Length
130 mm
Package Level 1 Gross Weight
1.3 kg
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Version
F
Current Type
AC
Electrical Durability
8000 cycle | 120 cycles per hour
Mechanical Durability
25000 cycle | 240 cycles per hour
Number of Poles
3P
Power Loss
at Rated Operating Conditions per Pole 10.8 W
Rated Current (In)
160 A
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Insulation Voltage (Ui)
1000 V
Rated Operational Voltage
690 V AC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 100 kA | (230 V AC) 100 kA | (240 V AC) 100 kA | (380 V AC) 70 kA | (415 V AC) 70 kA | (440 V AC) 65 kA | (500 V AC) 50 kA | (525 V AC) 30 kA | (690 V AC) 15 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(220 V AC) 100 kA | (230 V AC) 100 kA | (240 V AC) 100 kA | (380 V AC) 70 kA | (415 V AC) 70 kA | (440 V AC) 65 kA | (500 V AC) 50 kA | (525 V AC) 30 kA | (690 V AC) 15 kA
Rated Uninterrupted Current (Iu)
160 A
Release
Ekip Touch LSI
Release Type
EL
Short-Circuit Performance Level
H
Standards
IEC60947-2 | GB/T 14028.2
Sub-type
XT2
Terminal Connection Type
Front
Data Sheet, Technical Information
SACE Tmax XT IEC Low voltage molded case circuit-breakers Catalog | SACE Tmax XT IEC TECHNICAL CHARACTERISTICS Low voltage molded case circuit-breakers
Declaration of Conformity - CE
EC Declaration of Conformity Tmax XT2
Instructions and Manuals
Installation Instructions XT2 | Operation and maintenance manual for Ekip Touch Trip Units for SACE Tmax XT2-XT4
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
Feature: Front terminal connection enables straightforward wiring and secure terminations. Business Impact: faster wiring and reduced risk of loose connections, cutting installation time in half for panel builds. Application: retrofit projects and new control panels in automated lines. Feature: 3P 160 A rating with 690 V AC operating voltage ensures dependable protection for medium-sized loads. Business Impact: consistent protection in motor feeders and distribution blocks, improving system uptime and reducing nuisance trips. Application: packaging, material handling, and process lines. Feature: Ics up to 100 kA and Icu up to 100 kA across multiple voltages deliver robust short-circuit performance. Business Impact: minimizes arc-damage risk and equipment downtime during faults. Application: high-energy motor starters and power distribution cabinets. Feature: Ekip Touch LSI release provides precise, adjustable trip characteristics. Business Impact: easier fault diagnosis, better selectivity, and reduced maintenance intervention. Application: critical process lines requiring reliable fault isolation. Feature: Compliance and environmental data including IEC60947-2, RoHS, REACH, CMRT, SCIP, and EPD support procurement and sustainability goals. Business Impact: simplifies regulatory compliance and ESG reporting. Application: enterprise-scale panel assemblies and global deployments. Feature: Compatible with SACE Tmax XT family and front-access wiring design. Business Impact: accelerates migration projects and reduces training needs for field technicians. Application: new builds and modernizations in control rooms and machine enclosures.

Get a Quick Quote for a ABB 2TFN000097A1001

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 2TFN000097A1001? Enquire Now

FAQs

This unit uses a front-terminal connection designed for quick, secure wiring inside control panels. Plan panel space for a 90 mm width x 130 mm height footprint and ensure adequate clearance for terminal torque and access during maintenance. Refer to the XT2/Xt4 installation manuals for torque specifications and wiring sequences.
The device is 3P with a 160 A rated current, 690 V AC rated operational voltage, and Ui of 1000 V. It provides Ics up to 100 kA and Icu up to 100 kA depending on voltage, with a release unit Ekip Touch LSI and a short-circuit performance level of H, meeting IEC60947-2 requirements.
Yes. The 3P 160 A rating and 690 V AC capability, combined with front-terminal installation and the Ekip Touch LSI release, make it well-suited for motor feeders and distribution panels in automation lines, offering reliable protection, fast fault isolation, and easy integration with Tmax XT family devices.
It complies with IEC 60947-2, and CE conformity. Additional declarations include RoHS and REACH, plus CMRT and SCIP data where applicable, aligning with global regulatory and sustainability requirements for safe, responsible procurement.
Ekip Touch LSI provides precise, adjustable protection settings and clear fault indication, reducing diagnostic time and enabling selective tripping. This lowers downtime, extends equipment life, and improves overall return on investment through shorter maintenance windows and fewer unnecessary trips.