ABB 2TFN000141A1001 Moulded Case Circuit Breaker - IEC60947-2
Part Number: 2TFN000141A1001
Quick Summary
ABB 2TFN000141A1001 Moulded Case Circuit Breaker provides reliable protection for 690 V AC industrial switchgear and power distribution. Designers struggle with mis-trips and downtime caused by outdated devices and incompatible trip units. The device complies with IEC60947-2 and CE conformity, and ABB EcoSolutions documents include an EPD and EN45555 recyclability guidance, supporting sustainable procurement. With Ekip Touch LSIG release and XT2 lineage, it delivers precise protection, fast commissioning, and easy field retrofit, helping you reduce maintenance costs and improve overall plant uptime. Its 4P configuration and 160 A rating support high-demand lines while front-terminal connections simplify panel wiring. This makes commissioning faster and reduces risk during panel upgrades.
Product Information
Extended Description
2TFN000141A1001 ABB: XT2H 160 Ekip Touch LSIG In=160A 4p F F
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions
Disassembly instructions Tmax XT XT2 ELT
Environmental Product Declaration - EPD
EPD Tmax XT XT2 ELT (CN)
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 55.7 %
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Environmental Information
Breakers - Packaging disposal information
Customs Tariff Number
85362000
Product Net Width
120.0 mm
Product Net Height
130 mm
Product Net Depth / Length
82.5 mm
Product Net Weight
1.6 kg
Package Level 1 Width
150 mm
Package Level 1 Height
214 mm
Package Level 1 Depth / Length
130 mm
Package Level 1 Gross Weight
1.7 kg
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Version
F
Current Type
AC
Electrical Durability
8000 cycle | 120 cycles per hour
Mechanical Durability
25000 cycle | 240 cycles per hour
Number of Poles
4P
Power Loss
at Rated Operating Conditions per Pole 10.8 W
Rated Current (In)
160 A
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Insulation Voltage (Ui)
1000 V
Rated Operational Voltage
690 V AC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 100 kA | (230 V AC) 100 kA | (240 V AC) 100 kA | (380 V AC) 70 kA | (415 V AC) 70 kA | (440 V AC) 65 kA | (500 V AC) 50 kA | (525 V AC) 30 kA | (690 V AC) 15 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(220 V AC) 100 kA | (230 V AC) 100 kA | (240 V AC) 100 kA | (380 V AC) 70 kA | (415 V AC) 70 kA | (440 V AC) 65 kA | (500 V AC) 50 kA | (525 V AC) 30 kA | (690 V AC) 15 kA
Rated Uninterrupted Current (Iu)
160 A
Release
Ekip Touch LSIG
Release Type
EL
Short-Circuit Performance Level
H
Standards
IEC60947-2 | GB/T 14028.2
Sub-type
XT2
Terminal Connection Type
Front
Data Sheet, Technical Information
SACE Tmax XT IEC Low voltage molded case circuit-breakers Catalog | SACE Tmax XT IEC TECHNICAL CHARACTERISTICS Low voltage molded case circuit-breakers
Declaration of Conformity - CE
EC Declaration of Conformity Tmax XT2
Instructions and Manuals
Installation Instructions XT2 | Operation and maintenance manual for Ekip Touch Trip Units for SACE Tmax XT2-XT4
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
The 4P XT2 moulded case design with a 160 A nominal current rating delivers robust fault isolation for demanding 690 V AC powers within machine controls and distribution boards, reducing the incidence of nuisance trips and unplanned downtime. Benefit: improved line availability and safer equipment protection, supporting reliable uptime in process and manufacturing environments. The front-terminal connection simplifies wiring during panel assembly, enabling quicker installation and easier maintenance, cutting commissioning time and minimizing wiring errors. Benefit: faster project delivery and lower labor costs. The 8 kV rated impulse withstand and 1000 V insulation voltage provide margin for transient events and extended equipment life in harsh electrical environments, supporting compliance with IEC60947-2 while enabling safer, more durable installations. Benefit: reduced replacement costs and enhanced system resilience. The Ekip Touch LSIG release offers precise trip calculations and diagnostics, enabling accurate protection settings and straightforward field adjustments. Benefit: improved protection accuracy and faster fault analysis in automation silos and MCCs. ABB EcoSolutions support, including the EN45555 recyclability guidance and EPD, helps buyers meet sustainability targets and green procurement requirements. Benefit: aligns with corporate ESG goals and supplier sustainability programs. The device's compact footprint and weight of 1.6 kg (per unit) facilitate panel density optimization and easier handling, reducing shipping and storage costs. Benefit: optimized bill of materials and lower total cost of ownership. The unit's ratings—Ics up to 100 kA and Icu up to 100 kA at multiple voltages—provide confidence across multi-volt distributions and industrial load profiles. Benefit: mitigates risk for high-energy applications such as motors and heavy machinery while maintaining safe, code-compliant operation. The RoHS compliant and CMRT-ready profile ensures global supply chain compatibility, supporting regulatory alignment and traceability across sourcing channels. Benefit: smoother global procurement and risk management for multinational projects.
Get a Quick Quote for a ABB 2TFN000141A1001
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 2TFN000141A1001?
Enquire Now
FAQs
Begin by confirming panel clearance for a 120 mm width and 82.5 mm depth device. Ensure the 4P unit is the correct replacement for the existing slot and that the busbar and wiring clearances meet local codes. Use the front-terminal connections to speed up wiring, tighten to the specified torque, and verify insulation and clearance with a checklist. After installation, program the Ekip Touch LSIG trip unit to the desired IN = 160 A, ensuring coordination with downstream protection devices. Finally, perform functional and insulation tests per the installation manual to confirm correct operation.
Key ratings include rated current IN of 160 A, rated operating voltage 690 V AC, rated insulation voltage Ui of 1000 V, rated impulse withstand voltage Uimp of 8 kV, and short-circuit breaking capacities Ics and Icu of up to 100 kA across multiple voltages. Number of poles is 4P, with front-terminal connection. Release type is EL, and the release name is Ekip Touch LSIG, aligning with IEC60947-2 requirements.
Yes. The 4P XT2 MCCB with 160 A rating and 100 kA short-circuit capacity is well-suited for motor control centers and process panels that require reliable overcurrent protection at 690 V AC. The Ekip Touch LSIG provides precise protection settings, diagnostics, and coordination with other protection devices, improving startup reliability and reducing nuisance trips during motor startup transients.
The device complies with IEC 60947-2 and GB/T 14028.2. It carries CE Declaration of Conformity and benefits from ABB EcoSolutions documentation, including an Environmental Product Declaration (EPD) for Tmax XT XT2 ELT and EN45555 recyclability guidance. RoHS compliance is outlined under EU directives 2011/65/EU and amendments, and CMRT is available for responsible sourcing reporting.
With 8000 electrical durability cycles and 25000 mechanical cycles, the XT2 MCCB supports long lifecycles in demanding environments. The LSIG trip unit enables quick diagnostics and precise tripping, reducing maintenance troubleshooting time. Energy loss is about 10.8 W per pole under rated conditions, contributing to predictable operating costs. Overall, you gain improved uptime, safer operation, and favorable total cost of ownership for plant-wide protection schemes.