ABB 2TGA100059R1001 CPX5.3 Control and Protective Switching Device - CCC
Part Number: 2TGA100059R1001
Quick Summary
ABB 2TGA100059R1001 CPX5.3 Control and Protective Switching Device is designed for reliable leakage protection in industrial control panels. In many facilities, nuisance faults and delayed alerts from traditional protection modules create downtime and safety risk. It carries CCC Declaration of Conformity and CMRT reporting, aligning with global safety standards and responsible sourcing. By integrating a compact 400V/5.3A leakage protection with a 20–50 mA threshold and alarm output, it simplifies panel wiring and improves maintenance planning. This combination supports efficient compliance and fast diagnostics, while offering CPX100 data sheet compatibility to streamline engineering workflows.
Product Information
Extended Description
2TGA100059R1001 ABB: CPS 400V/5.3A 漏电保护(20-50mA)/2开2闭/报警信号输出
Minimum Order Quantity
1 piece
Customs Tariff Number
85371098
Product Main Type
CPX5.3
Data Sheet, Technical Information
Catalogue (.PDF) [ZH] CPX100 Control and Protection Switches
Instructions and Manuals
Manual (.PDF) [ZH] CPX100 Manual
Product Net Width
132 mm
Product Net Depth / Length
132 mm
Product Net Height
224.5 mm
Product Net Weight
3 kg
Power Loss
2 W
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Declaration of Conformity - CCC
CCC Declaration of Conformity, Control and Protective Switching Devices, CPX100, Made in China
Package Level 1 Units
carton 1 piece
Package Level 1 Width
147 mm
Package Level 1 Depth / Length
188 mm
Package Level 1 Height
271 mm
Package Level 1 EAN
6975486351936
Package Level 2 Units
box 6 piece
Package Level 2 Width
485 mm
Package Level 2 Depth / Length
295 mm
Package Level 2 Height
410 mm
Feature → Business Impact → Application: Leakage protection with adjustable 20–50 mA threshold reduces leakage current risks, improving operator safety and energy management. In practice, this enables faster fault isolation in motor control centers and packaging lines, lowering downtime and service costs while meeting stringent safety requirements. Feature → Business Impact → Application: 400V/5.3A capacity supports standard industrial motors, enabling seamless integration into existing panel architectures and reducing redesign time for upgrades. This benefits OEMs and maintenance teams by enabling plug‑and‑play compatibility with CPX100 products and related protection devices. Feature → Business Impact → Application: 2NO/2NC contact configuration provides flexible wiring options for local control and remote signaling, simplifying installation in compact control cabinets and reducing wiring errors during commissioning. Feature → Business Impact → Application: Alarm signal output delivers real‑time fault notifications to SCADA or maintenance interfaces, enabling proactive maintenance and faster response to leakage events in critical processes. Feature → Business Impact → Application: Compact dimensions and a 3 kg weight improve space utilization in crowded panels while enabling straightforward retrofits in legacy installations, minimizing downtime during upgrades. Feature → Business Impact → Application: Low power loss (2 W) contributes to overall energy efficiency in distributed protection schemes, reducing thermal load and cooling requirements in large switchgear assemblies. Feature → Business Impact → Application: CCC conformity and CMRT documentation enhance compliance transparency and supplier due‑diligence, supporting audit readiness and responsible sourcing in regulated industries. These features collectively improve installation reliability, shorten commissioning cycles, and deliver measurable ROI through reduced downtime and clearer maintenance planning.
Get a Quick Quote for a ABB 2TGA100059R1001
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 2TGA100059R1001?
Enquire Now
FAQs
The CPX5.3 module uses a 2NO/2NC configuration, allowing flexible wiring into standard control cabinets. Connect the phase lines through the device for leakage protection, wire the alarm output to your PLC/SCADA, and ensure the 400V supply matches your system. Follow CPX100 data sheets for pinout diagrams and safety clearances to minimize commissioning time.
Key specs include a 400V operating voltage, 5.3A rated current, and a leakage threshold adjustable between 20 and 50 mA. Use the internal adjustment mechanism or documented configuration steps in the CPX100 manual to set the threshold. This ensures early fault detection while avoiding nuisance trips in typical motor protection scenarios.
Yes, the device is designed for 400V protection with a defined leakage current band, making it suitable for 3-phase motor circuits in packaging and manufacturing lines. For hazardous environments, verify enclosure integrity, acceptable IP ratings, and ensure the CCC conformity covers your regional requirements—and consult the CPX100 data sheets for installation guidelines.
The module carries a CCC Declaration of Conformity and CMRT documentation, providing visibility into conformity and supply chain sourcing. For audits, reference the CPX100 data sheets and ensure your installation aligns with local electrical standards. Maintain the CCC documentation and related manuals on-site for quick verification during inspections.
Regularly inspect the alarm output integrity and verify leakage threshold accuracy during preventive maintenance. Benefits include reduced downtime from quicker fault detection, improved safety compliance, and streamlined troubleshooting with clear alarm signaling. The device’s compact footprint and energy‑efficient 2 W loss also contribute to lower thermal load and easier retrofits.