ABB 2TGA100102R1001 CPX9 - CCC Certified Device
Part Number: 2TGA100102R1001
Quick Summary
ABB CPX9 control and protective switching device is designed for safe, reliable protection in industrial control panels. Engineers often struggle to source hardware that provides leakage protection (20–50 mA) without complicating panel wiring or increasing downtime. Key certifications and declarations accompany this device, including CCC Declaration of Conformity for CPX100 devices and CMRT reporting, with Made in China compliance. With compact dimensions and a manageable weight, it fits standard enclosures and minimizes heat load, while ensuring compliance and serviceability; this supports faster procurement cycles and lower total cost of ownership.
Product Information
Extended Description
2TGA100102R1001 ABB: CPS 400V/9A 消防型带漏电保护(20-50mA)/4开4闭
Minimum Order Quantity
1 piece
Customs Tariff Number
85371098
Product Main Type
CPX9
Data Sheet, Technical Information
Catalogue (.PDF) [ZH] CPX100 Control and Protection Switches
Instructions and Manuals
Manual (.PDF) [ZH] CPX100 Manual
Product Net Width
132 mm
Product Net Depth / Length
132 mm
Product Net Height
224.5 mm
Product Net Weight
3 kg
Power Loss
2 W
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Declaration of Conformity - CCC
CCC Declaration of Conformity, Control and Protective Switching Devices, CPX100, Made in China
Package Level 1 Units
carton 1 piece
Package Level 1 Width
147 mm
Package Level 1 Depth / Length
188 mm
Package Level 1 Height
271 mm
Package Level 1 EAN
6975486352360
Package Level 2 Units
box 6 piece
Package Level 2 Width
485 mm
Package Level 2 Depth / Length
295 mm
Package Level 2 Height
271 mm
Feature → Business Impact → Application: Leakage-protected switching (20–50 mA) embedded in the CPX9 design reduces nuisance trips and improves fault isolation, delivering safer start-ups and ongoing reliability in critical control circuits. This translates to reduced unplanned downtime and easier regulatory compliance in process plants and machine rooms. Application: control panels requiring robust leakage protection and precise fault handling. Feature → Business Impact → Application: 400V/9A power rating supports common industrial loads with headroom for motor starters and safety interlocks, enabling scalable panel designs and easier expansion without rewiring. Application: medium-duty automation installations. Feature → Business Impact → Application: Low power loss of 2 W minimizes heat generation and cooling requirements, cutting energy costs and extending component life in confined enclosures. Application: hot or densely populated control panels. Feature → Business Impact → Application: Four open and four closed contacts (4x NO/NC) provide versatile signal and control routing, reducing the need for additional relays and enabling more compact panels. Application: multi-circuit protection and status monitoring in safety circuits. Feature → Business Impact → Application: 3 kg weight and 132 mm footprint support straightforward replacement and retrofit in existing CPX100-based systems, accelerating procurement and installation timelines. Application: retrofits and upgrades in legacy automation setups. Feature → Business Impact → Application: CMRT and CCC conformity streamline supply chain compliance, reduce supplier audits, and help meet electronics-supply chain obligations in global projects. Application: regulated industries and multi-site deployments.
Get a Quick Quote for a ABB 2TGA100102R1001
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 2TGA100102R1001?
Enquire Now
FAQs
Before integrating, verify the device fits the CPX100 family footprint, supports 400V mains, and offers four NO/NC contact configurations. Check enclosure dimensions (132 mm width/depth) and ensure mounting clearance for heat dissipation. Review the user manuals (CPX100 data) to confirm wiring schemes and protective functions align with your safety architecture.
Key specs include 400V operating voltage, 9A current rating, leakage protection in the 20–50 mA range, and a 2 W power loss. The device provides four open and four closed contacts, enabling versatile control wiring. These specs support reliable protection in standard industrial control panels while keeping heat and energy use minimal.
Yes. The CPS/CPX9 family is designed for protection with leakage sensing, making it suitable for safety-critical circuits and fire-safety control panels. The 20–50 mA leakage protection helps detect ground faults or insulation failures early, reducing risk and downtime in critical processes when paired with compatible control logic.
The device carries CCC Declaration of Conformity for CPX100 controllers and CMRT reporting. These declarations support regulatory compliance in manufacturing environments and supply-chain transparency. While CE/IEC markings are common in many regions, always verify regional requirements and any additional certifications needed for your installation site.
Expected benefits include reduced wiring complexity, lower heat generation due to 2 W loss, and a compact footprint that simplifies maintenance access. The four-form contact configuration minimizes the need for extra relays, lowering materials cost and installation time, while CMRT and CCC conformities ease supplier audits and cross-site procurement, improving total cost of ownership.