ABB 2TGA100162R1001 CPX25 Control Device - CCC
Part Number: 2TGA100162R1001
Quick Summary
ABB 2TGA100162R1001 CPX25 Control Device provides reliable control and protection for industrial switchgear. Engineers often struggle to find compact, compliant modules that integrate with CPX100 families without compromising safety or uptime. CCC Declaration of Conformity and CMRT support regulatory compliance and responsible sourcing across global sites, simplifying supplier audits and customer approvals. The device delivers a 400V/25A rating with leakage protection from 100 to 500 mA, while occupying a compact footprint; this enables faster panel assembly, easier maintenance, and improved system reliability in automation projects. This combination translates to lower lifecycle costs and smoother project approvals for OEMs and integrators.
Product Information
Extended Description
2TGA100162R1001 ABB: CPS 400V/25A 消防型带漏电保护(100-500mA)/4开4闭
Minimum Order Quantity
1 piece
Customs Tariff Number
85371098
Product Main Type
CPX25
Data Sheet, Technical Information
Catalogue (.PDF) [ZH] CPX100 Control and Protection Switches
Instructions and Manuals
Manual (.PDF) [ZH] CPX100 Manual
Product Net Width
132 mm
Product Net Depth / Length
132 mm
Product Net Height
224.5 mm
Product Net Weight
3 kg
Power Loss
2 W
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Declaration of Conformity - CCC
CCC Declaration of Conformity, Control and Protective Switching Devices, CPX100, Made in China
Package Level 1 Units
carton 1 piece
Package Level 1 Width
147 mm
Package Level 1 Depth / Length
188 mm
Package Level 1 Height
271 mm
Package Level 1 EAN
6975486352964
Package Level 2 Units
box 6 piece
Package Level 2 Width
485 mm
Package Level 2 Depth / Length
295 mm
Package Level 2 Height
410 mm
Feature: 400V/25A rating with CPX25 topology. Business Impact: Enables reliable, safe switching of industrial loads while maximizing panel density and reducing wiring complexity. Application: Motor starters and controlled loads in electrical cabinets. Feature: 4 NO / 4 NC switching with leakage protection 100–500 mA. Business Impact: Provides robust fault isolation and enhanced operator safety, reducing arc flash risk and unplanned downtime. Application: Multi-line protection in compact control panels. Feature: Compact footprint and weight (132 mm W x 132 mm D, 224.5 mm H; 3 kg). Business Impact: Easier installation, minimal mounting space, and lower chassis stress; improves maintenance accessibility. Application: Space-constrained control enclosures in automated lines. Feature: Power loss of 2 W and energy-conscious design. Business Impact: Lower operating heat and cooler panel environment, contributing to energy efficiency and reduced cooling loads. Application: Continuous operation in production lines with tight thermal budgets. Feature: CMRT and CCC conformity with documented manuals and data sheets. Business Impact: Streamlined compliance, faster approvals, and traceable supply chain for global projects. Application: Automotive, packaging, and process industries requiring formal declarations. Feature: Clear packaging and logistics info (carton 1 piece, EAN 6975486352964; box 6 pieces). Business Impact: Reliable stocking, predictable lead times, and efficient warehouse handling. Application: Procurement and logistics planning for large-scale deployments.
Get a Quick Quote for a ABB 2TGA100162R1001
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 2TGA100162R1001?
Enquire Now
FAQs
To install the 2TGA100162R1001 with CPX100 protection switches, begin by verifying the panel enclosure is rated for 400V operation and that wiring gauge meets 25A circuit requirements. Mount the device securely, connect the NO/NC contacts per the control scheme, and integrate the leakage protection sensor within the 100–500 mA range. Finally, perform a functional test to confirm proper isolation and switching performance, and document the configuration for compliance audits.
The device is rated for 400V operation at up to 25A and features leakage protection in the 100–500 mA range. It occupies a compact footprint with net dimensions of 132 mm width, 132 mm depth, and 224.5 mm height, weighs 3 kg, and has a power loss of approximately 2 W. These specs support efficient protection and control within standard electrical panels.
Yes, the 2TGA100162R1001 is designed to complement CPX100 family devices, delivering reliable protection and control in industrial panels. For harsh environments, ensure proper enclosure rating and mounting practices, and consider additional conformal coatings or environmental protection measures where required. Always verify compatibility with your specific panel design and safety standards before deployment.
The device carries CCC Declaration of Conformity for Control and Protective Switching Devices and is aligned with CMRT (Conflict Minerals Reporting Template) requirements. These certifications help streamline audits, support responsible sourcing initiatives, and facilitate global deployments in regulated industries such as manufacturing and process automation.
By consolidating control and protection in a single CPX25 device with 100–500 mA leakage protection and a compact footprint, you reduce wiring complexity, panel space, and installation time. This translates to lower labor costs, quicker commissioning, and improved uptime. Over the project life, the device supports predictable maintenance costs and regulatory compliance, improving overall ROI for OEMs and integrators.