ABB ACH580-BCR-096A-4 HVAC Drive - UL Type 1/12 Enclosure

Part Number: 3AUA0000225665
Manufacturer
ABB
Part number
3AUA0000225665

Quick Summary

ABB ACH580-BCR-096A-4 HVAC drive is a configurable speed controller for packaged HVAC systems. Integrating a bypass starter, disconnect, and protection can reduce wiring complexity and shorten install times. UL-listed operation with a NEMA Type 1/12/3R enclosure, a bypass motor starter, and electronic motor overload protection address safety and reliability in demanding commercial environments. Local control is streamlined by a door-mounted graphical display, while external control connections and serial communications enable seamless integration with building management systems. Designed for 1 to 350 hp at 230/460/575 V, it delivers energy-efficient motor control for commercial and light industrial HVAC, helping lower lifecycle costs and downtime.

Product Information

Extended Description

3AUA0000225665 ABB: The ACH580 with ABB E-Clipse bypass has an integrated UL (NEMA) Type 1, 12 or 3R enclosure with a bypass motor starter and is available from 1 to 350 hp at 230/460/575 V. The ACH580 with ABB E-Clipse bypass provides an input disconnect switch or circuit breaker, both including fast acting drive fuses, with door mounted and interlocked switch (padlockable in the OFF position), a bypass starter, electronic motor overload protection, a door mounted control panel with graphical display for local control, provisions for external control connections, and serial communications capability.
Feature: E-Clipse bypass with integrated bypass motor starter eliminates the need for a separate bypass setup, reducing wiring complexity and installation time. Business Impact: Shorter project timelines and lower labor costs, with improved reliability during bypass operation in HVAC applications. Application: Suitable for rooftop units and air handlers requiring bypassed operation without sacrificing protection or control. Feature: UL-listed performance with a NEMA Type 1/12/3R enclosure integrates the drive, disconnect, and fuses in a single enclosure. Business Impact: Safer installations, fewer components, and easier code compliance in commercial environments. Application: Ideal for space-constrained electrical rooms in office buildings and data centers. Feature: Door-mounted control panel with a graphical display plus serial communications and external control connections. Business Impact: Local and remote control options reduce commissioning time and support building management system integration. Application: Quick diagnostics and remote monitoring for ongoing maintenance efficiency. Feature: Wide voltage and horsepower range—1 to 350 HP at 230/460/575 V—plus electronic overload protection. Business Impact: Flexible deployment across multiple HVAC loads, lowering spare parts and enabling scalable lifecycle management. Application: Multizone systems and variable air volume (VAV) installations. Feature: Fast-acting drive fuses and padlockable OFF action ensure dependable protection and secure shutdown. Business Impact: Enhanced safety and reduced accidental re-energization risk in maintenance windows. Application: Environments with frequent service or tamper resistance requirements in commercial facilities.

Get a Quick Quote for a ABB 3AUA0000225665

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 3AUA0000225665? Enquire Now

FAQs

This drive integrates a bypass starter and a door-mounted control panel within a UL-listed UL/NEMA Type 1/12/3R enclosure. It supports an input disconnect or circuit breaker with fast-acting drive fuses and a padlockable OFF position, reducing wiring, panel space, and safety risks during commissioning and maintenance.
The ACH580-BCR-096A-4 is rated for up to 75 HP with 96 A current at 460 V per the UL specification. It also covers a broad range from 1 to 350 HP and supports 230/460/575 V, enabling flexible deployment across HVAC equipment such as air handlers and rooftop units.
Yes. The unit’s E-Clipse bypass, integrated bypass starter, and enclosure options are specifically designed for packaged HVAC systems like rooftop units and air handlers. Its local and remote control capabilities, plus serial communications, simplify integration with building management systems and improve commissioning efficiency.
The ACH580-BCR-096A-4 is UL-listed and designed for NEMA Type 1, 12 or 3R enclosure configurations. This combination supports robust safety, compatibility with typical HVAC electrical rooms, and streamlined compliance with facility codes and safety requirements.
By consolidating bypass, protection, and control into a single unit, maintenance visits are faster and less error-prone. The integrated fuses, bypass starter, and electronic overload protection reduce panel wiring, spare parts, and downtime, delivering a shorter payback period and longer system availability for commercial HVAC installations.