ABB ACH580-VDR-077A-4 HVAC Drive with E-Clipse Bypass - UL Type 1 Enclosure
Part Number: 3AUA0000225762
Quick Summary
ABB ACH580-VDR-077A-4 HVAC drive provides precise motor control for commercial and industrial HVAC systems. This configurable drive helps tackle common maintenance and reliability challenges by integrating a bypass motor starter and a dedicated input disconnect option, reducing repair downtime. The solution is built around a UL (NEMA) Type 1 enclosure with a bypass switch, fast-acting drive fuses, and a door-mounted control panel for local control. With electronic motor overload protection and serial communications, it aligns with standard industrial safety and control practices. An accessible control interface and robust protection translate into lower lifecycle costs, improved uptime, and scalable efficiency for HVAC applications while supporting downstream automation integration.
Product Information
Extended Description
3AUA0000225762 ABB: The ACH580 with ABB E-Clipse bypass has an integrated UL (NEMA) Type 1 enclosure with a bypass motor starter and is available from 1 to 75 hp at 230/460/575 V. The ACH580 with ABB E-Clipse bypass provides an input disconnect switch or circuit breaker, both including fast acting drive fuses, with door mounted and interlocked switch (padlockable in the OFF position), a bypass starter, electronic motor overload protection, a door mounted control panel with graphical display for local control, provisions for external control connections, and serial communications capability
Feature → Business Impact → Application: The ACH580-VDR-077A-4 includes a built-in ABB E-Clipse bypass and a bypass starter, enabling rapid maintenance without removing power to the rest of the system, which minimizes downtime during service and rebuilds for large air-handling units. This directly reduces HVAC downtime costs and improves system availability in manufacturing plants and commercial facilities. Feature → Business Impact → Application: It offers an input disconnect switch or circuit breaker with fast-acting drive fuses, enhancing safety and reliability during startup and fault conditions, while meeting electrical protection standards. This is especially valuable in retrofit projects and new installs where safety and compliance drive procurement decisions. Feature → Business Impact → Application: The drive supports 230/460/575 V operation and 1 to 75 hp ratings, enabling a single platform to cover a range of fan and pump duties across multiple plants, simplifying inventory and reducing total cost of ownership. Feature → Business Impact → Application: Local control via a door-mounted graphical display panel, plus external control connections and serial communications, improves commissioning speed and remote diagnostics, enabling faster troubleshooting and better integration with building management systems. Feature → Business Impact → Application: Electronic motor overload protection and interlocked, padlockable OFF position improve motor safety and reduce the risk of accidental restarts, which is critical for maintenance personnel and operator safety in high-energy HVAC environments. Feature → Business Impact → Application: The enclosure’s UL Type 1 rating and robust mechanical protection ensure reliable performance in typical indoor mechanical rooms, supporting compliance with plant safety standards while delivering energy-efficient motor control for fans and pumps. This combination of bypass capability, protection features, and integrated control accelerates ROI by lowering energy usage and maintenance costs for HVAC systems across industrial facilities and office campuses.
Get a Quick Quote for a ABB 3AUA0000225762
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 3AUA0000225762?
Enquire Now
FAQs
Install the ACH580-VDR-077A-4 inside a UL Type 1 enclosure, connect the 230/460/575 V supply to the drive terminals, and wire the input disconnect or circuit breaker with the fast-acting drive fuses as specified. Attach the bypass starter and interlock the door-mounted control panel. Ensure external control connections and serial communications are properly terminated and that the padlockable OFF position is secured during maintenance.
The ACH580-VDR-077A-4 supports 230/460/575 V operation with a 60 Hp rating (77 A at 460 V) and is designed for 1 to 75 Hp applications. It includes electronic motor overload protection and a bypass starter, enabling efficient motor control for fans and pumps while maintaining protection and diagnostics through built-in control features.
Yes. The ACH580-VDR-077A-4 is specifically designed for HVAC applications, providing precise speed control, energy efficiency, and protection for fans and pumps. The E-Clipse bypass and integrated control panel simplify commissioning, while the UL Type 1 enclosure supports safe indoor installation in mechanical rooms and equipment spaces.
The drive features a UL (NEMA) Type 1 enclosure, which supports safe indoor installation and reliable protection in mechanical rooms. It also includes a bypass starter, door-mounted interlock, and padlockable OFF to enhance maintenance safety. While CE and IP ratings are common in ABB portfolios, ensure your regional variant meets the specific regulatory requirements for your installation.
By integrating a bypass, fast-acting fuses, and electronic overload protection, the ACH580-VDR-077A-4 minimizes downtime during maintenance and reduces risk of unplanned outages. Energy-efficient speed control lowers operating costs, while onboard diagnostics and remote communications shorten mean time to repair and improve system reliability, delivering a favorable return on investment for HVAC-driven fans and pumps.