ACH580 HVAC drive provides precise motor control for packaged HVAC systems. Maintenance teams often face downtime from complex wiring and late-start issues; integrating a bypass and disconnect on the drive reduces field faults and speeds service. UL-listed with a NEMA Type 1, 12, or 3R enclosure protects equipment across indoor and outdoor installations, while an input disconnect or circuit breaker with fast-acting fuses adds safety. The built-in motor overload protection and door-mounted control panel simplify commissioning and diagnostics. In industrial automation terms, this drive aligns with energy-efficiency targets, supports serial communications for plant-wide control, and delivers reliable performance for critical HVAC applications.

Product Information

Extended Description

3AUA0000225785 ABB: The ACH580 with ABB E-Clipse bypass has an integrated UL (NEMA) Type 1, 12 or 3R enclosure with a bypass motor starter and is available from 1 to 350 hp at 230/460/575 V. The ACH580 with ABB E-Clipse bypass provides an input disconnect switch or circuit breaker, both including fast acting drive fuses, with door mounted and interlocked switch (padlockable in the OFF position), a bypass starter, electronic motor overload protection, a door mounted control panel with graphical display for local control, provisions for external control connections, and serial communications capability.
Feature: ACH580 includes ABB E-Clipse bypass with an integrated bypass motor starter and an input disconnect switch or circuit breaker, complete with fast-acting drive fuses. Business Impact: This packaging minimizes field wiring, reduces installation time, and simplifies safety compliance by consolidating components in one enclosure. Application: Ideal for HVAC packaged drives, air handlers, and roof-top units where rapid maintenance and reliable bypass are required. Feature: The drive is available with UL (NEMA) Type 1, 12, or 3R enclosure options. Business Impact: Protects sensitive electronics from dust, moisture, and outdoor conditions, lowering failure rates and extending service intervals. Application: Suitable for indoor mechanical rooms and outdoor equipment housings in commercial buildings and industrial sites. Feature: The ACH580 provides a door-mounted control panel with a graphical display. Business Impact: Speeds commissioning, troubleshooting, and local control without a separate HMI, reducing on-site labor and downtime. Application: Great for installation in equipment cabinets where technicians perform initial setup and ongoing parameter adjustments. Feature: Electronic motor overload protection complements the bypass starter and automatic current limiting. Business Impact: Enhances safety, reduces false tripping, and assists regulatory compliance in critical HVAC and process applications. Application: Used in fan & pump duty—where consistent torque and protection are essential. Feature: Built-in support for external control connections and serial communications. Business Impact: Enables seamless integration with building management systems and plant-wide automation, improving monitoring and control efficiency. Application: Connects to DDC/PLC networks and supervisory systems for centralized energy management. Feature: Broad horsepower and voltage range—1 to 350 hp across 230/460/575 V configurations. Business Impact: Provides scalable drive sizing with a single platform, reducing spare parts and training costs. Application: Suits HVAC compressors, fans, and pumps across small to large facilities.

Get a Quick Quote for a ABB 3AUA0000225785

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 3AUA0000225785? Enquire Now

FAQs

For proper installation, select the correct voltage (230/460/575 V) and horsepower (1–350 hp) range, plan for the E-Clipse bypass integration, and confirm enclosure type aligns with the environment. The drive supports both input disconnects and circuit breakers, aiding compliance and reducing wiring complexity during field deployment.
Key specs include 1–350 hp, 230/460/575 V, integrated E-Clipse bypass with bypass starter, electronic motor overload protection, and a door-mounted graphical control panel. It also offers serial communications capability, making it suitable for integration with broader automation and monitoring systems.
Yes. The drive is designed for HVAC packaged units, fans, and pumps, combining precise speed control with a compact enclosure. Its bypass option simplifies maintenance, while the local display and external control connections support quick setup and easy integration with BAS/PLC networks for centralized optimization.
The ACH580-BCR-077A-4 is UL-listed with NEMA Type 1, 12, or 3R enclosure options. This provides indoor and protected outdoor protection, ensuring compliance with common electrical safety standards and reducing environmental exposure risks in various installation sites.
The drive reduces downtime through integrated bypass and safer maintenance with a door-mounted panel, while offering energy savings via precise motor control. Centralized monitoring and compatibility with automation networks enable proactive maintenance and optimization, leading to lower operating costs and longer asset life in HVAC and related applications.