ABB ACH580-BCR-04A8-4+B058 HVAC Drive - UL Type 1 Bypass
Part Number: 3AUA0000225808
Quick Summary
ABB ACH580-BCR-04A8-4+B058 is an HVAC packaged drive that provides bypass motor control for HVAC fans and pumps. In tight equipment spaces, consolidating drive, bypass, and disconnect reduces wiring complexity and field wiring errors. This solution is UL-listed and designed for rugged enclosures (NEMA Type 1, 12, or 3R) with CE and IP-ready expectations to support global installations. Deploying this integrated drive delivers faster commissioning, easier maintenance, and improved energy efficiency, offering a strong value proposition for building services, mechanical contractors, and OEMs. By choosing a single, compact solution, you can reduce spare parts and streamline compliance documentation across multiple sites.
Product Information
Extended Description
3AUA0000225808 ABB: The ACH580 with ABB E-Clipse bypass has an integrated UL (NEMA) Type 1, 12 or 3R enclosure with a bypass motor starter and is available from 1 to 350 hp at 230/460/575 V. The ACH580 with ABB E-Clipse bypass provides an input disconnect switch or circuit breaker with door mounted and interlocked switch (padlockable in the OFF position), a bypass starter, electronic motor overload protection, a door mounted control panel with graphical display for local control, provisions for external control connections, and serial communications capability
Feature E-Clipse bypass is integrated with a bypass motor starter. Business Impact By eliminating separate bypass assemblies, maintenance time is reduced and reliability is improved during routine service. Application HVAC fans and pumps in commercial and industrial facilities benefit from quick switchover and simplified wiring. Feature UL Type 1/12/3R enclosure provides robust protection for electronics in standard indoor and more demanding environments. Business Impact This enclosure variety minimizes ingress risk and protects against dust and moisture, reducing field failures and warranty costs. Application Indoor equipment rooms and mechanical spaces requiring durable protection. Feature Input disconnect switch or circuit breaker with door interlock and padlockable OFF. Business Impact Enhances safety compliance and lockout/tagout procedures during maintenance. Application Service isolation for fans, pumps, and compressors. Feature Electronic motor overload protection builds in. Business Impact Reduces motor burnout risk and trip events, extending motor life and lowering downtime. Application Variable torque and constant torque HVAC loads. Feature Door-mounted control panel with graphical display supports local control and quick commissioning. Business Impact Speeds setup, debugging, and troubleshooting, lowering commissioning labor costs. Application Site start-up and on-site diagnostics. Feature Serial communications capability enables integration with building management systems. Business Impact Enables remote monitoring, fault alerts, and energy management without on-site visits. Application BAS/BMS integration and centralized control.
Get a Quick Quote for a ABB 3AUA0000225808
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 3AUA0000225808?
Enquire Now
FAQs
Install the ACH580-BCR-04A8-4+B058 in a suitable UL Type 1/12/3R enclosure per the manufacturer's wiring diagram. Mount the unit to a stable rack or panel, connect the drive to 230/460/575 V supply, and wire the bypass and disconnect as specified. Use the padlockable OFF position for safe servicing, and configure the local control panel for basic commissioning before integrating with a BAS/BMS.
Key specs include 230/460/575 V input, 1–350 hp motor range, and a bypass starter with E-Clipse bypass. Protection features include electronic motor overload protection and an integrated input disconnect or circuit breaker with interlocked, padlockable OFF. The drive supports serial communications for remote monitoring and control, enabling reliable performance across HVAC loads.
Yes. The ACH580 platform is designed for HVAC fans and pumps, offering scalable power from 1 to 350 hp with multi-voltage support. The integrated bypass, enclosure options, and local/remote control capabilities make it ideal for commercial buildings, data centers, and industrial HVAC applications seeking energy efficiency and simplified maintenance.
This ABB solution is UL-listed for performance and safety and is designed for rugged NEMA Type 1/12/3R enclosure installations. While CE marking and IP-rated considerations are common in many regions, the described enclosure options and UL listing provide a strong basis for regional compliance and safe operation in HVAC environments.
The integrated E-Clipse bypass eliminates separate bypass hardware, reducing downtime during maintenance and speeding component swaps. The electronic motor overload protection and a door-mounted control panel simplify diagnostics, lowering service labor and improving mean time between failures (MTBF). Overall, you gain lower maintenance costs and faster issue resolution, contributing to a favorable return on investment.