ABB ACH580-BCR-027A-6+B058 HVAC Drive - E-Clipse Bypass UL Type 1

Part Number: 3AUA0000227004
Manufacturer
ABB
Part number
3AUA0000227004

Quick Summary

The ABB ACH580-BCR-027A-6+B058 HVAC drive is a compact variable frequency drive with an integrated E-Clipse bypass for packaged HVAC systems. Engineers often struggle with downtime and wiring complexity when bypassing drives during maintenance, risking safety and project timelines. This unit ships in UL-listed, NEMA Type 1, 12 or 3R enclosures and includes a bypass motor starter, electronic overload protection, and a door-mounted control panel for intuitive local control. By combining a flexible interface, robust protection, and straightforward installation, it supports reliability and faster commissioning. The result is improved energy efficiency, easier serviceability, and seamless integration with external control connections and serial communications for scalable building automation.

Product Information

Extended Description

3AUA0000227004 ABB: The ACH580 with ABB E-Clipse bypass has an integrated UL (NEMA) Type 1, 12 or 3R enclosure with a bypass motor starter and is available from 1 to 350 hp at 230/460/575 V. The ACH580 with ABB E-Clipse bypass provides an input disconnect switch or circuit breaker with door mounted and interlocked switch (padlockable in the OFF position), a bypass starter, electronic motor overload protection, a door mounted control panel with graphical display for local control, provisions for external control connections, and serial communications capability
Feature: Integrated E-Clipse bypass with bypass motor starter. Business Impact: Reduces maintenance downtime and simplifies safe bypass operations during service, improving system uptime and safety. Application: Ideal for HVAC packaged drives in rooftop units and air handling systems. Feature: UL (NEMA) Type 1, 12 or 3R enclosure options. Business Impact: Meets common real-world enclosure standards, enabling compliant installations in varied environments and jurisdictions. Application: Suitable for commercial buildings and industrial facilities requiring durable protection with straightforward access. Feature: Input disconnect switch or circuit breaker with door-mounted interlocked operation. Business Impact: Enhances safety and lockout/tagout compliance while maintaining ease of access for maintenance. Application: Critical for service teams that perform routine shutdowns during seasonal HVAC cycles. Feature: Electronic motor overload protection and door-mounted control panel with graphical display. Business Impact: Protects motors from overload, reduces nuisance trips, and provides clear diagnostics to speed troubleshooting. Application: Improves commissioning accuracy and ongoing performance monitoring in AHUs and air handlers. Feature: 1–350 hp at 230/460/575 V with serial communications capability. Business Impact: Supports broad HVAC power ranges and scalable control integration with building management systems. Application: Suitable for small to large commercial HVAC installations, including retrofit projects. Feature: External control connections and compact installation footprint. Business Impact: Simplifies wiring, speeds installation, and enables modular integration with other controls or PLCs. Application: Works well in tight mechanical rooms where space is at a premium.

Get a Quick Quote for a ABB 3AUA0000227004

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 3AUA0000227004? Enquire Now

FAQs

The ACH580-BCR-027A-6+B058 is a packaged HVAC drive designed to control motors in commercial air handling, rooftop units, and other packaged HVAC systems. It combines a variable frequency drive with an E-Clipse bypass, allowing safe bypass maintenance and simplified control wiring. It supports up to 350 hp at three voltage options (230/460/575 V) and includes protection features to safeguard motor health.
Yes. The ACH580-BCR-027A-6+B058 supports 230, 460, and 575 V supply and covers a horsepower range from 1 to 350 hp. This voltage flexibility makes it suitable for a wide range of HVAC motor sizes and allows easier integration with existing electrical infrastructure and building systems.
The drive is available in UL-listed enclosures corresponding to NEMA Type 1, Type 12, or Type 3R options, providing protection suitable for indoor mechanical rooms and outdoor locations. It also includes an input disconnect or circuit breaker, an interlocked door-mounted control panel, and safety interlocks, which support safe operation and straightforward maintenance.
E-Clipse bypass integrates a bypass starter that lets the drive be bypassed without removing power from the system, reducing downtime during maintenance. The combined arrangement simplifies service routines, minimizes wiring changes, and maintains motor control continuity, which is especially valuable in critical HVAC applications with strict uptime requirements.
Consider enclosure type selection (UL/NEMA per environment), availability of the door-mounted graphical control panel for local monitoring, and the need for external control connections and serial communications. Ensure compatibility with 230/460/575 V mains and confirm motor compatibility up to 350 hp. Plan for proper safety interlocks and lockout/tagout procedures during commissioning.