ABB ACH580-VDR-024A-2 HVAC Drive - UL Type 1 Enclosure

Part Number: 3AUA0000227486
Manufacturer
ABB
Part number
3AUA0000227486

Quick Summary

The ACH580-VDR-024A-2 HVAC drive provides precise speed control for commercial HVAC systems. Facilities often struggle with downtime, complex bypass wiring, and safety compliance when upgrading existing drives. UL Type 1 enclosure with E-Clipse bypass and built-in motor protection support safe, reliable operation in busy plant environments. This drive also suits 230 V systems with scalable horsepower and easy integration with existing controls, reducing lifecycle costs and downtime. With modular voltage support and bypass options, maintenance teams can stock fewer parts and perform faster service. The approach aligns with facilities’ energy-efficiency initiatives and regulatory readiness for modern HVAC control. It also supports remote monitoring, improving asset reliability.

Product Information

Extended Description

3AUA0000227486 ABB: The ACH580 with ABB E-Clipse bypass has an integrated UL (NEMA) Type 1 enclosure with a bypass motor starter and is available from 1 to 75 hp at 230/460/575 V. The ACH580 with ABB E-Clipse bypass provides an input disconnect switch or circuit breaker, both including fast acting drive fuses, with door mounted and interlocked switch (padlockable in the OFF position), a bypass starter, electronic motor overload protection, a door mounted control panel with graphical display for local control, provisions for external control connections, and serial communications capability
Feature: E-Clipse bypass with a bypass motor starter and an integrated UL Type 1 enclosure. Business Impact: streamlines installation by consolidating bypass wiring and reducing field connections, which lowers project risk and startup times. Application: ideal for HVAC fan motors and air-handling units where compact, serviceable drive solutions minimize downtime and retrofit challenges. Real-world benefit: fewer door interlocks and integrated protection translate to faster commissioning and safer operation in busy mechanical rooms. Feature: Input disconnect switch or circuit breaker with fast-acting drive fuses, door-mounted interlocked switch (padlockable in OFF). Business Impact: enhances safety during maintenance, supports lockout/tagout procedures, and reduces accidental energization. Application: service corridors and rooftop units where technicians require guaranteed de-energization before work, and owners demand regulatory compliance. Feature: Electronic motor overload protection and a door-mounted control panel with graphical display for local control. Business Impact: protects motor windings, lowers nuisance trips, and provides intuitive local diagnostics to speed up troubleshooting. Application: field tuning and daily checks on HVAC drives, enabling rapid adjustments without a separate handheld programmer. Feature: Broad voltage and horsepower range from 1 to 75 hp and 230/460/575 V compatibility. Business Impact: consolidates procurement and spare parts, reduces stock keeping units, and supports a single drive family across multiple HVAC apps. Application: retrofit projects and new installations spanning rooftop units, air handlers, and remotely located fans where space and wiring complexity matter. Feature: Serial communications capability and provisions for external control connections. Business Impact: enables seamless integration with building management systems and remote monitoring for predictive maintenance, increasing asset uptime. Application: centralized control of fans, pumps, and auxiliary equipment in commercial buildings, hospitals, and data centers.

Get a Quick Quote for a ABB 3AUA0000227486

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 3AUA0000227486? Enquire Now

FAQs

Yes. The ACH580-VDR-024A-2 is designed for 230 V operation and includes an integrated E-Clipse bypass with a bypass motor starter, reducing external wiring. It simplifies commissioning and minimizes field interconnections, while the door-mounted interlock enhances safety. When installing, verify NEC and local code compliance and ensure proper wiring layout for a clean, reliable bypass path.
Key specs include 7.5 hp at 230 V with a rated current of 24.2 A, and a scalable range from 1 to 75 hp across 230/460/575 V. The drive provides electronic motor overload protection and supports a bypass starter, enabling robust performance for variable-speed control in HVAC applications.
Yes. The ACH580-VDR-024A-2 is tailored for HVAC applications such as air handlers and fans, offering precise speed control, integrated bypass, and a compact UL Type 1 enclosure. Its 1 to 75 hp range and multi-voltage support make it suitable for a variety of downtown or campus buildings and retrofit projects.
The unit features a UL (NEMA) Type 1 enclosure, which supports indoor installation safety and compliance with standard motor drive practices. It also includes a door-mounted interlocked switch and protection features, helping meet safety requirements during installation, commissioning, and maintenance in commercial HVAC environments.
The built-in bypass, motor overload protection, and local graphical display reduce maintenance complexity and downtime. Centralized control options and serial communications improve remote monitoring and integration with building management systems, enabling predictive maintenance and energy-saving operation—contributing to a lower total cost of ownership and faster return on investment.