ABB ACH580-BCR-059A-2 HVAC Drive - E-Clipse Bypass UL Type 1
Part Number: 3AUA0000227509
Quick Summary
ABB ACH580-BCR-059A-2 HVAC drive is a packaged motor controller for HVAC systems. It delivers reliable speed control and protection, simplifying setup for fans, pumps, and air handling units. This drive is designed with UL Type 1/12/3R enclosure ratings and includes an integrated E-Clipse bypass, a bypass starter, and fast-acting drive fuses to meet safety and performance standards. By combining centralized control with local accessibility, it reduces commissioning time, lowers maintenance costs, and supports scalable automation in modern buildings.
Product Information
Extended Description
3AUA0000227509 ABB: The ACH580 with ABB E-Clipse bypass has an integrated UL (NEMA) Type 1, 12 or 3R enclosure with a bypass motor starter and is available from 1 to 350 hp at 230/460/575 V. The ACH580 with ABB E-Clipse bypass provides an input disconnect switch or circuit breaker, both including fast acting drive fuses, with door mounted and interlocked switch (padlockable in the OFF position), a bypass starter, electronic motor overload protection, a door mounted control panel with graphical display for local control, provisions for external control connections, and serial communications capability.
Bypass capability: The ACH580 features ABB E-Clipse bypass with a dedicated bypass starter and a door-mounted, interlocked switch that can be padlocked in the OFF position. Business impact: minimizes downtime during maintenance and eliminates the need for separate bypass wiring, speeding service windows and enhancing safety. Application: ideal for HVAC packaged units and air handlers where routine motor maintenance must occur without interrupting critical loads. Enclosure and safety integration: It offers a UL Type 1/12/3R enclosure along with an input disconnect or circuit breaker, both incorporating fast-acting drive fuses. Impact: streamlines code compliance and protects personnel and equipment in compact controls cabinets. Application: indoor and outdoor installations requiring robust protection and easy access to the drive. Local control and diagnostics: The door-mounted control panel includes a graphical display and supports external control connections with serial communications capability. Impact: reduces commissioning time, supports remote monitoring, and simplifies troubleshooting. Application: building automation integrations and on-site startup. Protection and performance: Electronic motor overload protection guards against overload events, improving motor life and reducing unplanned outages. Impact: lowers total cost of ownership through fewer trips and longer motor life. Application: HVAC fans and pumps with variable load profiles. Range and flexibility: The drive supports 1 to 350 hp across 230/460/575 V configurations, enabling broad compatibility with existing and new equipment. Impact: simplifies retrofits and new installations, reducing inventory and engineering effort. Application: retrofits of legacy fans, pumps, and air handlers. Communication and integration: Serial communications and external control connections enable seamless integration with PLCs and building management systems. Impact: unlocks endpoint data access, alarms, and coordinated control for energy optimization. Application: smart facilities and demand-driven HVAC strategies.
Get a Quick Quote for a ABB 3AUA0000227509
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 3AUA0000227509?
Enquire Now
FAQs
Begin with a proper panel layout that supports a UL Type 1/12/3R enclosure. Mount the ACH580 in a space with adequate clearance, connect the door-mounted control panel wiring, and wire the input disconnect or circuit breaker with the fast-acting drive fuses. Ensure the E-Clipse bypass is wired to a dedicated bypass starter and verify the interlock is padlocked in OFF during maintenance. Follow the device documentation for commissioning steps and safety checks to achieve a reliable startup.
The drive supports 230/460/575 V supply and covers a wide horsepower range from 1 to 350 hp. In the common 230 V configuration, it provides up to 59.4 A in the example rating (20 HP at 230 V). It includes electronic motor overload protection, a bypass option via E-Clipse, and serial communications capability for integration with control networks.
Yes. The ACH580-BCR-059A-2 is designed for retrofit into HVAC units such as rooftop units and air handlers, thanks to its broad voltage and HP range (230/460/575 V, 1–350 hp) and its integrated bypass and protection features. Its door-mounted control panel simplifies commissioning, while the UL enclosure ratings help meet installation codes and safety requirements for building retrofits.
The E-Clipse bypass includes a bypass starter and a door-mounted interlocked switch that can be padlocked in OFF, enabling safe maintenance without powering the load. The drive also includes fast-acting fuses and electronic motor overload protection, reducing risk of thermal damage and electrical faults. This combination supports safer maintenance, quicker service windows, and improved compliance with safety standards.
ROI is driven by reduced downtime, safer maintenance via the integrated bypass, and fewer external components due to the all-in-one enclosure and wiring. The electronic overload protection extends motor life, while the graphical control panel speeds commissioning and diagnostics. Over time, facilities benefit from lower service costs, improved uptime for HVAC loads, and energy-efficient operation through precise motor control.