ABB ACH580 3AUA0000227517 HVAC Drive - UL Type 1
Part Number: 3AUA0000227517
Quick Summary
ABB ACH580 HVAC drive with E-Clipse bypass delivers precise motor control for packaged HVAC systems. Engineers and facilities teams often wrestle with energy waste, space constraints in panels, and downtime during start-up. UL-listed with optional NEMA Type 1, 12, or 3R enclosures supports safe, code-compliant installations, while built in overload protection adds reliability. With 1–350 hp capability and support for 230/460/575 V, it delivers scalable efficiency and dependable operation across HVAC networks. This combination helps procurement teams simplify sourcing and maintenance planning, driving better total cost of ownership in commercial and industrial environments.
Product Information
Extended Description
3AUA0000227517 ABB: The ACH580 with ABB E-Clipse bypass has an integrated UL (NEMA) Type 1, 12 or 3R enclosure with a bypass motor starter and is available from 1 to 350 hp at 230/460/575 V. The ACH580 with ABB E-Clipse bypass provides an input disconnect switch or circuit breaker with door mounted and interlocked switch (padlockable in the OFF position), a bypass starter, electronic motor overload protection, a door mounted control panel with graphical display for local control, provisions for external control connections, and serial communications capability
Feature: The ACH580 integrates the ABB E-Clipse bypass and bypass motor starter. Business impact: Minimizes disruptive downtime during bypass operations and simplifies serviceability, reducing maintenance costs. Application: Ideal for packaged HVAC systems where reliable bypass is required. Feature: UL listing with optional NEMA Type 1, 12, or 3R enclosures. Business impact: Enables safe, code-compliant installations across different facility environments, improving installation flexibility. Application: Suitable for rooftop units, air handlers, and core HVAC equipment in varying indoor/outdoor conditions. Feature: Wide horsepower and voltage range (1–350 hp, 230/460/575 V). Business impact: Reduces the need for multiple drives, lowers spare parts inventory, and accelerates project timelines. Application: Broad applicability from small fans to large pumps in commercial buildings. Feature: Input disconnect or circuit breaker with door interlock and padlockable OFF. Business impact: Enhances safety and regulatory compliance during maintenance and service work. Application: Critical for emergency shutoff scenarios and strict lockout/tagout procedures. Feature: Door mounted control panel with graphical display. Business impact: Speeds commissioning, troubleshooting, and local control without additional hardware. Application: Field service and on-site startups in HVAC installations. Feature: Serial communications capability. Business impact: Facilitates remote monitoring, integration with DCS/SCADA, and centralized energy management. Application: Industrial HVAC networks requiring data visibility and control. Feature: Electronic motor overload protection. Business impact: Protects motors from thermal damage, reduces unplanned outages, and extends motor life. Application: High duty cycle HVAC fans and pumps under varying loads.
Get a Quick Quote for a ABB 3AUA0000227517
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 3AUA0000227517?
Enquire Now
FAQs
Yes. The ACH580 is designed for 230/460/575 V supply and covers a broad horsepower range from 1 to 350 hp, making it suitable for HVAC fans, pumps, and packaged units. It supports straightforward field wiring, bypass integration, and easy replacement in existing electrical rooms, helping to minimize downtime during retrofit or new installs.
Key specs include horsepower range from 1 to 350 hp, voltage support at 230/460/575 V, and integrated E-Clipse bypass with a bypass starter. It offers electronic motor overload protection, a door mounted control panel with graphical display, and optional serial communications for networked control, delivering reliable motor control and protection in HVAC applications.
Absolutely. The ACH580 is engineered for HVAC driven loads such as fans and pumps in commercial and light industrial environments. Its UL listed enclosure options and bypass functionality support safe operation, while its control panel and communication features enable precise speed control, energy savings, and integration with building management systems.
The drive supports UL listed enclosures with NEMA Type 1, 12, or 3R configurations for flexible installation in different environments. This enables safe operation in indoor spaces, outdoor protected areas, and control panels, ensuring compliance with common electrical codes and enabling easy service access during maintenance.
Expect improved energy efficiency from precise motor speed control, reduced downtime due to integrated bypass and protection features, and longer motor life from electronic overload protection. Remote monitoring and integration capabilities also enable proactive maintenance, reduced service calls, and a lower total cost of ownership over the drive’s life cycle.