ABB 3AUA0000227891 ACH580 Packaged Drive - UL Type 1
Part Number: 3AUA0000227891
Quick Summary
ABB ACH580 Packaged Drive powers HVAC fans and pumps with precise speed control. Engineers often wrestle with wiring complexity, space constraints, and safety when upgrading legacy drives. This solution is available in UL-listed NEMA Type 1 enclosures, with optional Type 12 or Type 3R versions to match indoor or more demanding environments. By integrating protection, a door-mounted control panel with a graphical display, and serial communications in a single package, it reduces commissioning time, simplifies maintenance, and lowers total cost of ownership for building automation and industrial HVAC installations. The unit supports a broad horsepower range and 230/460/575 V supplies, delivering reliable performance while meeting demanding regulatory and safety expectations.
Product Information
Extended Description
3AUA0000227891 ABB: The ACH580 Packaged Drive includes an ACH580 drive in a UL (NEMA) Type 1, 12 or 3R enclosure with input disconnect switch or circuit breaker, both including fast acting drive fuses. It is available from 1 to 350 hp at 230/460/575 V. The ACH580 Packaged Drive provides a door-mounted input disconnect switch (padlockable in the OFF position), electronic motor overload protection, a door-mounted control panel with graphical display for local control, provisions for external control connections, and serial communications capability.
Feature: Packaged drive with door-mounted input disconnect, fast-acting fuses, and electronic motor overload protection. Benefit: Enhances safety, simplifies wiring, and reduces incident risk during commissioning and maintenance. Application: Ideal for compact packaged HVAC units where space is at a premium and rapid, safe startup is required. Feature: HP range from 1 to 350 hp and 230/460/575 V capability. Benefit: Flexible sizing across a wide variety of fans, pumps, and blowers eliminates the need for multiple drives and lowers total lifecycle cost. Application: Commercial buildings, data centers, and industrial HVAC where load profiles vary seasonally. Feature: Door-mounted graphical control panel with local control. Benefit: Streamlines setup, troubleshooting, and commissioning, reducing downtime and on-site labor. Application: OEM assemblies and retrofit projects needing quick, intuitive control. Feature: Serial communications capability. Benefit: Enables remote monitoring, BMS integration, and diagnostics, improving uptime and energy management. Application: Integrated building automation and smart facility deployments. Feature: Enclosure options UL (NEMA) Type 1, Type 12, or Type 3R. Benefit: Deploys reliably in varied environments, from clean indoor spaces to outdoors with weather exposure. Application: HVAC setups in offices, hospitals, manufacturing floors, and maintenance corridors.
Get a Quick Quote for a ABB 3AUA0000227891
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 3AUA0000227891?
Enquire Now
FAQs
Begin by confirming the enclosure type (Type 1, 12, or 3R) and power supply (230/460/575 V). Install the door-mounted disconnect, fast-acting fuses, and the ACH580 Packaged Drive inside the enclosure. Connect motor, sensor, and control wiring, then configure local control via the built-in panel and verify serial communications are active for remote monitoring.
The drive supports 1–350 hp at 230/460/575 V and is equipped with electronic motor overload protection. It includes an input disconnect switch (padlockable OFF) and fast-acting drive fuses, enhancing safety and protecting both motor and drive from overloads during startup and running conditions.
Yes. The ACH580 Packaged Drive is designed for HVAC applications, delivering precise speed control for fans and pumps. Its wide hp and voltage range, combined with built-in protections and local control, supports efficient building ventilation, climate control, and energy savings in commercial installations.
The system is available in UL-listed NEMA Type 1 enclosures, with options for Type 12 and Type 3R where environmental conditions demand. This configuration supports regulatory compliance and safer operation in indoor, partially outdoor, and harsher environments depending on the selected enclosure.
Consolidating drive, disconnect, fuses, and control panel into a single packaged unit reduces installation time and wiring complexity, lowering labor costs. Electronic overload protection and robust enclosure options improve reliability, reducing downtime. Integrated serial communications also enables proactive maintenance and energy management for faster payback.