ABB ACH580-VCR-041A-6 HVAC Drive - UL Type 1 Enclosure with E-Clipse Bypass

Part Number: 3AUA0000233130
Manufacturer
ABB
Part number
3AUA0000233130

Quick Summary

ACH580-VCR-041A-6 HVAC drive optimizes HVAC fan and pump control in commercial buildings. Engineers often struggle to coordinate a safe isolation switch, bypass operation, and motor protection within a single panel. This unit features a UL Type 1 enclosure and an integrated E-Clipse bypass, delivering reliable protection and simplified wiring. With support for 1 to 75 hp at 230/460/575 V and a door-mounted graphical control panel, it helps meet demanding HVAC control and building automation requirements. By combining a bypass starter, fast-acting drive fuses, and external control connections, it enables faster commissioning, easier maintenance, and consistent performance across varying loads.

Product Information

Extended Description

3AUA0000233130 ABB: The ACH580 with ABB E-Clipse bypass has an integrated UL (NEMA) Type 1 enclosure with a bypass motor starter and is available from 1 to 75 hp at 230/460/575 V. The ACH580 with ABB E-Clipse bypass provides an input disconnect switch or circuit breaker, both including fast acting drive fuses, with door mounted and interlocked switch (padlockable in the OFF position), a bypass starter, electronic motor overload protection, a door mounted control panel with graphical display for local control, provisions for external control connections, and serial communications capability
Feature: Integrated E-Clipse bypass with bypass motor starter. Business Impact: Reduces wiring complexity and panel footprint while enabling rapid, safe bypass operation during service or start-up. Application: Ideal for HVAC drives in mechanical rooms where downtime must be minimized and safety interlocks must be preserved. Feature: UL (NEMA) Type 1 enclosure with door-mounted control panel. Business Impact: Simplifies installation in indoor environments and supports local control without extending enclosure space or chasing separate panels. Application: Building automation projects requiring compliant, compact control enclosures.Feature: Input disconnect switch or circuit breaker with fast-acting drive fuses. Business Impact: Enhances safety and ensures rapid isolation during fault conditions, reducing risk to personnel and equipment. Application: Critical in code-compliant HVAC installations where quick outage capability is essential.Feature: Electronic motor overload protection. Business Impact: Protects motors from thermal damage, extending motor life and reducing maintenance costs. Application: Continuous operation in variable-speed HVAC systems with fluctuating loads.Feature: Door-mounted control panel with graphical display and serial communications capability. Business Impact: Streamlines commissioning, diagnostics, and remote integration with building management systems. Application: Modern facilities leveraging BAS for centralized monitoring and control.Feature: Wide horsepower and voltage range (1–75 hp at 230/460/575 V). Business Impact: Maximizes equipment reuse across multiple projects, reducing spare parts and inventory costs. Application: Flexible solution for fans, pumps, and mixed HVAC duties in installations of varying scope.

Get a Quick Quote for a ABB 3AUA0000233130

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 3AUA0000233130? Enquire Now

FAQs

Installation involves mounting the drive inside a UL Type 1 enclosure, connecting to 230/460/575 V supply, wiring the input disconnect or circuit breaker, and routing the bypass wiring to the E-Clipse bypass circuit. The door-mounted control panel provides local control and protection features, while external connections support BAS integration. Follow ABB installation manuals for torque specs and safety interlocks.
The unit covers 1 to 75 hp, operates at 230/460/575 V, and draws up to about 41 A at the 40 hp region. It includes electronic motor overload protection, a bypass starter, and fast-acting drive fuses. It also offers serial communications for integration with other automation devices and a local control interface on the door-mounted panel.
Yes. The drive is specifically designed for HVAC loads, delivering precise speed control for fans and pumps, reduced energy consumption, and smooth torque for variable air volume operations. Its bypass and protection features ensure dependable operation in critical building systems and support building automation requirements.
The drive is built into a UL Type 1 (NEMA) enclosure for indoor installation and is designed to align with CE-ready requirements in applicable markets. It includes a bypass mechanism and electronic overload protection to support regulatory and safety standards, improving compliance in varied regional projects.
The integrated bypass and protection reduce external wiring and components, simplifying maintenance and shortening downtime during servicing. Energy savings come from precise speed control and reduced mechanical wear. The compact enclosure and universal voltage support also lower inventory costs and speed up project deployments.