Quick Summary
The ACH580 HVAC drive optimizes fan and pump control for commercial HVAC systems. Engineers often grapple with integrating a reliable bypass and disconnect that minimizes downtime during maintenance. This UL-listed device comes in a NEMA Type 1 enclosure and features electronic motor overload protection for safe, code-compliant operation. With 1 to 75 hp support and 230/460/575 V input options, it scales across diverse HVAC applications while delivering energy-efficient, easy-to-install performance. Designed to streamline building automation, it pairs well with PLCs and other control systems, reducing installation risk and total cost of ownership.
Product Information
Extended Description
3AUA0000233134 ABB: The ACH580 with ABB E-Clipse bypass has an integrated UL (NEMA) Type 1 enclosure with a bypass motor starter and is available from 1 to 75 hp at 230/460/575 V. The ACH580 with ABB E-Clipse bypass provides an input disconnect switch or circuit breaker, both including fast acting drive fuses, with door mounted and interlocked switch (padlockable in the OFF position), a bypass starter, electronic motor overload protection, a door mounted control panel with graphical display for local control, provisions for external control connections, and serial communications capability
Feature → Business Impact → Application: ABB E-Clipse bypass is integrated with a bypass starter, enabling a safe, fast transition between drive control and direct motor operation. This design minimizes HVAC system downtime during servicing and simplifies fault isolation, improving maintenance efficiency. In typical building automation applications, it reduces service time and accelerates return to full operation for fans and pumps. Feature → Business Impact → Application: The drive ships in a UL (NEMA) Type 1 enclosure with a door-mounted control panel, delivering safer local control and easier accessibility in restricted or console-less installations. This enhances compliance with safety standards while speeding commissioning for retrofit projects in commercial buildings. Feature → Business Impact → Application: An input disconnect switch or circuit breaker option, combined with fast-acting drive fuses, improves safety sequencing and protects equipment during startup and fault conditions. This supports code compliance and minimizes the risk of electrical faults propagating through the HVAC loop. Feature → Business Impact → Application: A broad voltage and horsepower range (1–75 hp, 230/460/575 V) provides flexible compatibility with legacy motors and future upgrades, reducing spare parts inventory and enabling phased modernization in industrial HVAC. Feature → Business Impact → Application: Serial communications capability enables remote monitoring, integration with building management systems (BMS), and PLC control, enhancing operability, alarm handling, and performance analytics for large facilities. Feature → Business Impact → Application: Electronic motor overload protection guards motors from short-term overloads, lowering maintenance costs and extending motor life in demanding HVAC duty cycles and variable load conditions.
Get a Quick Quote for a ABB 3AUA0000233134
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 3AUA0000233134?
Enquire Now
FAQs
Yes. The ACH580 supports 1 to 75 hp motors and voltages of 230/460/575 V, making it compatible with a wide range of HVAC motors. It features a door-mounted control panel for local control and provides options for an input disconnect or circuit breaker, simplifying retrofit installations and ensuring seamless integration with existing control architectures.
The specific ACH580-VDR-041A-6 variant corresponds to 40 Hp, 41 A, at 575 V. It includes the ABB E-Clipse bypass, electronic motor overload protection, and a bypass starter, delivering reliable performance for high-demand HVAC loads while enabling smooth transitions between drive control and direct motor operation.
Absolutely. The ACH580 is designed for HVAC applications requiring precise speed control and reliable bypass functionality. Its 230/460/575 V options and 1–75 hp range cover most commercial fan and pump duties, while the integrated bypass reduces downtime during service and improves system resilience in building automation projects.
The ACH580 with E-Clipse bypass is UL-listed and configured in a NEMA Type 1 enclosure, supporting safe operation in typical indoor environments. It includes electronic motor overload protection and a guarded, interlocked door with padlockable OFF position, enhancing safety and compliance with industrial controls standards.
By combining an integrated bypass with a bypass starter and fast-acting drive fuses, the ACH580 minimizes maintenance downtime and protects motors from overloads, which lowers service costs and extends motor life. Remote monitoring and building management integration further enable predictive maintenance and energy optimization, delivering a favorable total cost of ownership in HVAC installations.