ABB ACH580-BCR-096A-4+B058 Drive - E-Clipse Bypass
Part Number: 3AUD0000000001
Quick Summary
ABB ACH580-BCR-096A-4+B058 is an HVAC packaged drive for controlled fans and pumps. Engineers often struggle with integrating a reliable bypass, a safe disconnect, and protective interlocks in compact HVAC spaces. UL-listed safety features and NEMA enclosure options (Type 1, 12, or 3R) provide dependable protection in harsh environments. This drive also supports 230/460/575 V, 1 to 350 hp, and built‑in control capabilities, delivering energy efficiency and faster commissioning. Together, it simplifies installation, reduces wiring complexity, and helps maintain uptime across commercial and industrial HVAC systems.
Product Information
Extended Description
3AUD0000000001 ABB: The ACH580 with ABB E-Clipse bypass has an integrated UL (NEMA) Type 1, 12 or 3R enclosure with a bypass motor starter and is available from 1 to 350 hp at 230/460/575 V. The ACH580 with ABB E-Clipse bypass provides an input disconnect switch or circuit breaker with door mounted and interlocked switch (padlockable in the OFF position), a bypass starter, electronic motor overload protection, a door mounted control panel with graphical display for local control, provisions for external control connections, and serial communications capability
Feature → Business Impact → Application: The ACH580 with E-Clipse bypass integrates a bypass motor starter and electronic motor overload protection, reducing the number of separate components and simplifying maintenance while enhancing fault isolation in HVAC drives used on large fans and pumps. This translates to fewer field failures and lower commissioning time for building services projects. Application: Commercial rooftop units and central plant installations where reliability and quick service are critical. Feature → Business Impact → Application: An input disconnect switch or circuit breaker with a door-mounted, interlocked, padlockable OFF position improves safety and regulatory compliance, minimizing maintenance risk and unplanned downtime. Application: Any HVAC system requiring safe, accessible shutdown during service. Feature → Business Impact → Application: A door-mounted control panel with a graphical display and optional external control connections, plus serial communications, enables rapid commissioning and seamless integration with building management systems. Application: Retrofit projects and new builds needing easy remote monitoring. Feature → Business Impact → Application: Wide voltage and horsepower range (230/460/575 V, 1–350 hp) provides a single drive platform for multiple HVAC applications, reducing spare parts and engineering effort. Application: Mixed-load environments such as hospitals, data centers, and manufacturing facilities. Feature → Business Impact → Application: UL/NEMA Type 1/12/3R enclosure options streamline installation in varied environments, enabling compliant, durable installations with fewer enclosure changes during retrofit projects. Application: Industrial HVAC where space and protection requirements are stringent.
Get a Quick Quote for a ABB 3AUD0000000001
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 3AUD0000000001?
Enquire Now
FAQs
Yes. The ACH580 family is designed for three-phase operation at 230, 460, or 575 V, enabling direct compatibility with common HVAC power networks. It covers applications from 1 to 350 hp, providing a single, scalable solution for blower and pump drives while meeting NEC/UL electrical standards when wired and installed per the guidelines.
The drive includes an E-Clipse bypass with a bypass motor starter and electronic motor overload protection. It features a door-mounted, interlocked switch that is padlockable in the OFF position, improving maintenance safety and preventing unsafe bypass conditions during service and commissioning.
Yes, the ACH580 with E-Clipse bypass is designed for UL/NEMA Type 1/12/3R enclosures, enabling flexible installation in varied environments. The integrated enclosure and control panel reduce the need for separate cabinets, saving floor space and simplifying wiring, especially in retrofit projects where footprint and wiring complexity matter.
HVAC fans, pumps, and compressors benefit most, particularly in space-constrained or energy-conscious buildings. The drive provides precise speed control, reducing motor run-time energy consumption, lowers electrical stress, and offers smoother acceleration/deceleration, which translates into reduced peak demand charges and longer motor life in commercial and industrial HVAC systems.
ROI stems from energy savings, reduced wiring and components due to the integrated bypass and control, and higher uptime from improved protection features. Maintenance gains include easier diagnostics via serial communications, fewer field components to fail, and simpler service with door-mounted controls, ultimately lowering total cost of ownership over the system lifecycle.