ABB ACH580-31 ultra-low harmonic drive powers HVAC motors with precise speed control for commercial and industrial air-handling applications. This solution helps eliminate harmonic distortion that can shorten motor life and trigger nuisance trips, addressing downtime and maintenance costs. The system ships with UL-listed enclosure and NEMA-type options, including an integrated bypass starter and fast-acting drive fuses, alongside protective features like electronic motor overload protection and a door-mounted control panel. With external control connections and serial communications, it fits into modern plant automation while supporting scalable upgrades to higher horsepower ranges. For engineers seeking reliable, safe, and compliant drive technology, the ACH580-31 offers predictable performance and total lifecycle value.

Product Information

Extended Description

3AUD0000000721 ABB: The ACH580-31 ultra-low harmonic drive with ABB E-Clipse bypass has an integrated UL (NEMA) Type 1, 12 or 3R enclosure with a bypass motor starter and is available from 1 to 400 hp at 460 V. The ACH580-31 ultra-low harmonic drive with ABB E-Clipse bypass provides an input disconnect switch or circuit breaker, both including fast acting drive fuses, with door mounted and interlocked switch (padlockable in the OFF position), a bypass starter, electronic motor overload protection, a door mounted control panel with graphical display for local control, provisions for external control connections, and serial communications capability.
Feature: Ultra-low harmonic drive with ABB E-Clipse bypass reduces input current distortion and improves power quality. Business impact: Lower motor heating, extended bearing life, and reduced transformer and wiring losses translate into measurable energy savings and longer equipment life. Application: Ideal for HVAC fans and pumps where variable speed control minimizes peak demand while maintaining airflow and pressure setpoints. Feature: UL-listed enclosure options (Type 1/12/3R) with a bypass motor starter and interlocked door switch. Business impact: Enhanced maintenance safety, padlockable OFF, and easier compliance with site safety policies. Application: New installs or retrofits in facilities requiring robust protection in demanding environments. Feature: Integrated input disconnect or circuit breaker with fast-acting drive fuses and electronic motor overload protection. Business impact: Simplified wiring, quick isolation for service, and improved fault detection, reducing unscheduled downtime. Application: Industrial settings prone to power disturbances. Feature: Door-mounted control panel with graphical display; external control connections; serial communications. Business impact: Flexible local and remote control, faster commissioning, and seamless PLC/SCADA integration. Application: Automated HVAC systems and building management networks. Feature: 1 to 400 hp at 460 V compatibility and store-ready compatibility with full ABB drive family. Business impact: Inventory consolidation, scalable solutions for varied loads, and lower lifecycle costs. Application: Plants upgrading from fixed-speed motors to energy-efficient variable-speed drives.Feature: Electronic motor overload protection and integrated bypass for maintenance continuity. Business impact: Maximized uptime, safer maintenance windows, and reduced risk of motor damage. Application: Commercial rooftops, data centers, and manufacturing HVAC systems.

Get a Quick Quote for a ABB 3AUD0000000721

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 3AUD0000000721? Enquire Now

FAQs

Installers should plan for a 460 V power supply, space for the UL-listed enclosure, and proper cable routing to the door-mounted control panel. Include the option for a disconnect switch or circuit breaker and ensure fast-acting drive fuses are correctly sized. Verify interlock functionality for safe maintenance and confirm serial communication wiring for plant integration.
The ACH580-31 employs an ultra-low harmonic drive design with E-Clipse bypass to minimize input current distortion, reducing motor heating and improving power quality. The result is lower energy losses, extended motor life, and reduced electrical stress on feeders—benefiting HVAC fans, pumps, and other variable-speed loads.
Yes. With 1 to 400 hp at 460 V and UL/NEMA enclosure options, the ACH580-31 can replace fixed-speed or older VFDs in many HVAC applications. Its integrated bypass starter and protective features simplify integration with existing control schemes, while serial communications allow seamless PLC/SCADA compatibility during migration.
The drive is UL-listed and designed for UL (NEMA) Type 1, 12, or 3R enclosures, featuring an interlocked, padlockable door switch and a bypass starter. Additional safety comes from electronic motor overload protection, fast-acting fuses, and a robust control panel for local operation, ensuring compliance and safe maintenance.
Expected ROI comes from reduced harmonic currents, lower energy consumption, and decreased motor wear, which translate into energy and maintenance savings. The integrated bypass and comprehensive protection reduce downtime during servicing, while modular compatibility with ABB drives lowers spare-part and training costs over the equipment lifecycle.